Transient Elastography Measurements of Spleen Stiffness as a Predictor of Clinically Significant Varices in Children

被引:21
|
作者
Sutton, Harry [1 ,2 ,3 ]
Fitzpatrick, Emer [2 ,3 ,4 ]
Davenport, Mark [2 ,3 ]
Burford, Charlotte [1 ]
Alexander, Emma [1 ]
Dhawan, Anil [2 ,3 ,4 ]
Grammatikopoulos, Tassos [2 ,3 ,4 ]
机构
[1] Kings Coll London, London, England
[2] Kings Coll Hosp NHS Fdn Trust, Paediat Liver Gastroenterol & Nutr Ctr, London, England
[3] Kings Coll Hosp NHS Fdn Trust, MowatLabs, London, England
[4] Kings Coll Hosp London, Fac Life Sci & Med, Inst Liver Studies, London, England
来源
JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION | 2018年 / 67卷 / 04期
关键词
clinically significant varices; portal hypertension; spleen stiffness; transient elastography; PORTAL-HYPERTENSION; PRIMARY PROPHYLAXIS; ESOPHAGEAL-VARICES; LIVER; MANAGEMENT; HEMORRHAGE; RISK; RULE;
D O I
10.1097/MPG.0000000000002069
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objectives: Investigate the use of spleen stiffness measurements (SSMs), measured by transient elastography (TE), for the prediction of clinically significant varices (CSV) in children with portal hypertension. Methods: This observational cohort study included children selected for endoscopy, as per department protocol, between September 2015 and June 2016. Those included underwent single TE FibroScan for liver stiffness measurements and SSM. Clinical and laboratory data were collected and variceal prediction scores were calculated at time of elastography. Results: In total 67 children (32 boys) underwent TE. Fifty-two children (25 boys) had chronic liver disease (CLD), 15 (7 boys) portal vein thrombosis (PVT). In all children SSM was the best predictor of CSV+ve, with an optimal cut-off value of 38.0 kPa (area under the receiver operator curve [AUROC] = 0.92, sensitivity = 89%, specificity = 82%, P < 0.01). In the CLD group SSM was also the best predictor, with an optimal cut-off value of 38.05 kPa (AUROC = 0.90, sensitivity = 84%, specificity = 87%, P < 0.01). In the PVT group only SSM was predictive of CSV+ve, with an optimal cutoff value of 16.8 kPa (AUROC = 1.00, sensitivity = 100%, specificity = 100%, P < 0.001). For the prediction of GI bleeding (n = 6), liver stiffness measurement performed the best, with an optimal cut-off value of 34.3 kPa (AUROC = 0.84, sensitivity of 80%, specificity of 88%, P = 0.01). Conclusions: SSM was the greatest predictor of CSV+ve in the whole cohort, and individual CLD and PVT groups. SSM could be used as a noninvasive screening tool for children with portal hypertension to stratify the risk of having CSV.
引用
收藏
页码:446 / 451
页数:6
相关论文
共 50 条
  • [41] Diagnostic value of spleen stiffness by magnetic resonance elastography for prediction of esophageal varices in cirrhotic patients
    Zih-En Jhang
    Kuan-Lin Wu
    Chia-Bang Chen
    Yao-Li Chen
    Ping-Yi Lin
    Chen-Te Chou
    Abdominal Radiology, 2021, 46 : 526 - 533
  • [42] Diagnostic value of spleen stiffness by magnetic resonance elastography for prediction of esophageal varices in cirrhotic patients
    Jhang, Zih-En
    Wu, Kuan-Lin
    Chen, Chia-Bang
    Chen, Yao-Li
    Lin, Ping-Yi
    Chou, Chen-Te
    ABDOMINAL RADIOLOGY, 2021, 46 (02) : 526 - 533
  • [43] Hepatic inflammation may influence liver stiffness measurements by transient elastography in children and young adults
    Raizner, Aileen
    Shillingford, Nick M.
    Mitchell, Paul D.
    Harney, Sarah
    Raza, Roshan
    Serino, Jessica
    Jonas, Maureen M.
    Lee, Christine K.
    HEPATOLOGY, 2014, 60 : 290A - 290A
  • [44] Hepatic Inflammation May Influence Liver Stiffness Measurements by Transient Elastography in Children and Young Adults
    Raizner, Aileen
    Shillingford, Nick
    Mitchell, Paul D.
    Harney, Sarah
    Raza, Roshan
    Serino, Jessica
    Jonas, Maureen M.
    Lee, Christine K.
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2017, 64 (04): : 512 - 517
  • [45] Steatosis and Liver Stiffness Measurements Using Transient Elastography Reply
    Petta, Salvatore
    Craxi, Antonio
    HEPATOLOGY, 2016, 64 (02) : 701 - 701
  • [46] Performance of liver stiffness measurements by transient elastography in chronic hepatitis
    Giovanna Ferraioli
    Carmine Tinelli
    Barbara Dal Bello
    Mabel Zicchetti
    Raffaella Lissandrin
    Gaetano Filice
    Carlo Filice
    Elisabetta Above
    Giorgio Barbarini
    Enrico Brunetti
    Willy Calderon
    Marta Di Gregorio
    Roberto Gulminetti
    Paolo Lanzarini
    Serena Ludovisi
    Laura Maiocchi
    Antonello Malfitano
    Giuseppe Michelone
    Lorenzo Minoli
    Mario Mondelli
    Stefano Novati
    Savino FA Patruno
    Alessandro Perretti
    Gianluigi Poma
    Paolo Sacchi
    Domenico Zanaboni
    Marco Zaramella
    World Journal of Gastroenterology, 2013, (01) : 49 - 56
  • [47] Performance of liver stiffness measurements by transient elastography in chronic hepatitis
    Ferraioli, Giovanna
    Tinelli, Carmine
    Dal Bello, Barbara
    Zicchetti, Mabel
    Lissandrin, Raffaella
    Filice, Gaetano
    Filice, Carlo
    Above, Elisabetta
    Barbarini, Giorgio
    Brunetti, Enrico
    Calderon, Willy
    Di Gregorio, Marta
    Gulminetti, Roberto
    Lanzarini, Paolo
    Ludovisi, Serena
    Maiocchi, Laura
    Malfitano, Antonello
    Michelone, Giuseppe
    Minoli, Lorenzo
    Mondelli, Mario
    Novati, Stefano
    Patruno, Savino F. A.
    Perretti, Alessandro
    Poma, Gianluigi
    Sacchi, Paolo
    Zanaboni, Domenico
    Zaramella, Marco
    WORLD JOURNAL OF GASTROENTEROLOGY, 2013, 19 (01) : 49 - 56
  • [48] Transient Elastography for Spleen Stiffness Measurement in Patients With Cirrhosis Role in Degree of Thrombocytopenia
    Chien, Cheng-Hung
    Lin, Yi-Lan
    Chien, Rong-Nan
    Hu, Ching-Chih
    Yen, Cho-Li
    Lee, Tsung-Shih
    Hsieh, Po-Jen
    Lin, Chih-Lang
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (09) : 1849 - 1857
  • [49] Variability of transient elastography-based spleen stiffness performed at 100 Hz
    Armandi, Angelo
    Merizian, Talal
    Werner, Merle Marie
    Coxson, Harvey O.
    Sanavia, Tiziana
    Birolo, Giovanni
    Gashaw, Isabella
    Ertle, Judith
    Michel, Maurice
    Galle, Peter R.
    Labenz, Christian
    Emrich, Tilman
    Schattenberg, Joern M.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2023, 7 (01)
  • [50] Variability of transient elastography-based spleen stiffness performed at 100 Hz
    Angelo Armandi
    Talal Merizian
    Merle Marie Werner
    Harvey O. Coxson
    Tiziana Sanavia
    Giovanni Birolo
    Isabella Gashaw
    Judith Ertle
    Maurice Michel
    Peter R. Galle
    Christian Labenz
    Tilman Emrich
    Jörn M. Schattenberg
    European Radiology Experimental, 7