A Fast, Sensitive and Label Free Electrochemical DNA Sensor

被引:20
作者
Chen, Yu [1 ]
Elling, Yoke-ling Lee [2 ]
Chong, Ser-choong [1 ]
机构
[1] Inst Microelect, 11 Sci Pk Rd,Sci Pk 2, Singapore 117685, Singapore
[2] Natl Univ Singapore, Dept Biomol & Chem Engn, Singapore, Singapore
来源
INTERNATIONAL MEMS CONFERENCE 2006 | 2006年 / 34卷
关键词
electrochemical sensor; label free; DNA sensor; polypyrrole; pulsed amperometry;
D O I
10.1088/1742-6596/34/1/034
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A label free and sensitive DNA/RNA silicon based electrochemical microsensor array was developed by using thin film of the conducting polymer polypyrrole doped with an oligonucleotide probe. The electrochemical potential pulse amperometry technique was used for a biowarfare pathogen target DNA detection. The electrical potential assistanted DNA hybridisation method was applied. The sensor signal was increased by increasing the electrical potential assistanted DNA hybridisation time. It was possible to detect 0.34pmol and 0.072fmol of complementary oligonucleotide target in 0.1ml in seconds by using unpolished and polished gold electrode respectively. The probe preparation was also in seconds time, comparing indirect electrochemical DNA sensor, it has a fast sensor preparation as well as sensor response and label free advantages. The silicon microfabrication technique was used for this sensor array fabrication, which holds the potential to integrate with sensor electrical circuits. The conducting polymer polypyrrole was electrochemically deposited on each electrode respectively which has a possibility to dope the different DNA probe into the individual electrode to form a sensor array.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 7 条
[1]  
CHEN Y, 2003, Patent No. 6503847
[2]   An electrochemical detection scheme for identification of single nucleotide polymorphisms using hairpin-forming probes [J].
Huang, TJ ;
Liu, MS ;
Knight, LD ;
Grody, WW ;
Miller, JF ;
Ho, CM .
NUCLEIC ACIDS RESEARCH, 2002, 30 (12) :e55
[3]   Enzyme-amplified electrochemical detection of DNA using electrocatalysis of ferrocenyl-tethered dendrimer [J].
Kim, E ;
Kim, K ;
Yang, H ;
Kim, YT ;
Kwak, J .
ANALYTICAL CHEMISTRY, 2003, 75 (21) :5665-5672
[4]   Direct electrochemical sensor for fast reagent-free DNA detection [J].
Komarova, E ;
Aldissi, M ;
Bogomolova, A .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) :182-189
[5]   Carbon and gold electrodes as electrochemical transducers for DNA hybridisation sensors [J].
Lucarelli, F ;
Marrazza, G ;
Turner, APF ;
Mascini, M .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (06) :515-530
[6]   Pulsed amperometric detection of DNA with an ssDNA/polypyrrole-modified electrode [J].
Ramanaviciene, A ;
Ramanavicius, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (02) :287-293
[7]   Enzyme-amplified amperometric detection of 3000 copies of DNA in a 10-μL droplet at 0.5 fM concentration [J].
Zhang, YC ;
Kim, HH ;
Heller, A .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3267-3269