Comparison of plain radiographs with CT scan to evaluate interbody fusion following the use of titanium interbody cages and transpedicular instrumentation

被引:157
作者
Shah, RR
Mohammed, S
Saifuddin, A
Taylor, BA
机构
[1] Royal Natl Orthopaed Hosp, Stanmore HA7 4LP, Middx, England
[2] Hope Hosp, Manchester, Lancs, England
关键词
lumbar interbody fusion; plain radiographs; CT;
D O I
10.1007/s00586-002-0517-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The availability of lumbar interbody cages has fuelled renewed interest in interbody fusion. Despite this, there is no consensus regarding the best non-invasive method for evaluation of interbody fusion, especially where cages have been used. The purpose of this study was to determine whether high-quality thin-slice (1- to 3-mm) computed tomography (CT) scans allow proper evaluation of interbody fusion through titanium cages. Patients undergoing lumbar interbody fusion were prospectively evaluated with CT scan and plain radiographs 6 months following surgery. These images were blindly and independently evaluated by a consultant radiologist and a spine research fellow, for bridging bony trabeculation both through and surrounding the cages as well as for changes at the cage endplate interface. Fifty-three patients (156 cages) undergoing posterior lumbar interbody fusion using titanium interbody cages were evaluated. Posterior elements were used to pack the cages and no graft was packed outside the cages. The outcome data were analysed using the Kappa co-efficient and chi-squared analysis. On CT scan, both observers noted bridging trabeculation in 95% of the cages (Kappa 0.85), while on radiographs this was present in only 4% (Kappa 0.74). Both observers also identified bridging trabeculation surrounding the cages on CT scan in 90% of cages (Kappa 0.82), while on the radiographs this was 8% (Kappa 0.86). Radiographs also failed to demonstrate all the loose cages. The results of the study show that high-quality CT scans show images suggesting bridging bony trabeculae following the use of titanium interbody cages. They also appear to show consistent bone outside the cages in spite of no bone graft having been used, and they appear to be better than plain radiographs in the early detection of cage loosening.
引用
收藏
页码:378 / 385
页数:8
相关论文
共 32 条
[1]   CAN LUMBAR SPINE RADIOGRAPHS ACCURATELY DETERMINE FUSION IN POSTOPERATIVE-PATIENTS - CORRELATION OF ROUTINE RADIOGRAPHS WITH A 2ND SURGICAL LOOK AT LUMBAR FUSIONS [J].
BLUMENTHAL, SL ;
GILL, K .
SPINE, 1993, 18 (09) :1186-1189
[2]  
Boden SD, 1998, J SPINAL DISORD, V11, P95
[3]  
BOSWORTH DM, 1948, AAOS INSTR COURSE LE, V5, P295
[4]   A CARBON-FIBER IMPLANT TO AID INTERBODY LUMBAR FUSION - 2-YEAR CLINICAL-RESULTS IN THE 1ST 26 PATIENTS [J].
BRANTIGAN, JW ;
STEFFEE, AD .
SPINE, 1993, 18 (14) :2106-2117
[5]   Lumbar interbody fusion using the Brantigan I/F Cage for posterior lumbar interbody fusion and the variable pedicle screw placement system - Two-year results from a Food and Drug Administration Investigational Device Exemption Clinical Trial [J].
Brantigan, JW ;
Steffee, AD ;
Lewis, ML ;
Quinn, LM ;
Persenaire, JM .
SPINE, 2000, 25 (11) :1437-1446
[6]  
BRODSKY AE, 1991, SPINE S, V16, P261
[7]   PSEUDARTHROSIS IN THE LUMBOSACRAL SPINE [J].
CLEVELAND, M ;
BOSWORTH, DM ;
THOMPSON, FR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1948, 30-A (02) :302-312
[8]   Osteogenic protein versus autologous interbody arthrodesis in the sheep thoracic spine -: A comparative endoscopic study using the Bagby and Kuslich interbody fusion device [J].
Cunningham, BW ;
Kanayama, M ;
Parker, LM ;
Weis, JC ;
Sefter, JC ;
Fedder, IL ;
McAfee, PC .
SPINE, 1999, 24 (06) :509-518
[9]  
DUNN G, 1995, CLIN BIOSTATISTICS I
[10]   Analysis of titanium mesh cages in adults with minimum two-year follow-up [J].
Eck, KR ;
Bridwell, KH ;
Ungacta, FF ;
Lapp, MA ;
Lenke, LG ;
Riew, KD .
SPINE, 2000, 25 (18) :2407-2415