Indoor exposure from building materials: A field study

被引:150
作者
Missia, Dafni A. [1 ]
Demetriou, E. [2 ]
Michael, N. [2 ]
Tolis, E. I. [1 ]
Bartzis, J. G. [1 ]
机构
[1] Univ W Macedonia, Environm Technol Lab, Kozani 50100, Greece
[2] State Gen Lab, Nicosia, Cyprus
关键词
Building materials emissions; Volatile Organic Compounds (VOCs); Indoor Air Quality (IAQ); Field and Laboratory Emission Cell (FLEC); VOLATILE ORGANIC-COMPOUNDS; VOC EMISSIONS; RESIDENTIAL BUILDINGS; REFERENCE VALUES; SEASONAL CYCLE; FORMALDEHYDE; ENVIRONMENTS; ALDEHYDES; PRODUCTS; HYDROCARBONS;
D O I
10.1016/j.atmosenv.2010.07.049
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The present study has been conducted in the frame of BUMA (Prioritization of Building Materials Emissions as indoor pollution sources), a European funded project, aiming at assessing the exposure to emitted compounds in indoor air. Field campaigns in five (5) European cities (Milan, Copenhagen, Dublin, Athens and Nicosia) were carried out. These campaigns covered weekly winter and summer concentration measurements in two (2) public buildings and two (2) private houses in each city. BTEX, terpenes, and carbonyls were measured using passive sampling in two sites inside the building and one outside. VOC emission measurements on selected building material have also been performed using Field and Laboratory Emission Cell (FLEC). The results on indoor concentrations for compounds such as formaldehyde (1.2-62.6 mu g m(-3)), acetaldehyde (0.7-41.6 mu g m(-3)), toluene (0.9-163.5 mu g m(-3)), xylenes (0.2-177.5 mu g m(-3)) and acetone (2.8-308.8 mu g m(-3)) have shown diversity and relatively significant indoor sources depending on the building type, age etc. Indoor concentrations of these substances are varied depending on the building age and type. The percentage of approximately 40% of the indoor air quality levels originated from building materials. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4388 / 4395
页数:8
相关论文
共 51 条
[1]   Comparison of three small chamber test methods for the measurement of VOC emission rates from paint [J].
Afshari, A ;
Lundgren, B ;
Ekberg, LE .
INDOOR AIR, 2003, 13 (02) :156-165
[2]  
ALEVANTIS L, 2003, REPORT BUILDING MAT
[3]  
[Anonymous], 1997, 5116 ASTM INT
[4]  
[Anonymous], 2004, 160006 ISO
[5]  
[Anonymous], 1987, AIR QUALITY GUIDELIN
[6]  
[Anonymous], 2001, 160003 ISO
[7]  
[Anonymous], IARC MON S4
[8]  
Bartekova A, 2006, FOREST PROD J, V56, P85
[9]   Chamber assessment of formaldehyde and VOC emissions from wood-based panels [J].
Brown, SK .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1999, 9 (03) :209-215
[10]   Emissions of odorous aldehydes from alkyd paint [J].
Chang, JCS ;
Guo, ZS .
ATMOSPHERIC ENVIRONMENT, 1998, 32 (20) :3581-3586