The use of pesticides has been associated with the increase of productivity of crops and control of vectors that cause diseases. However, excessive use of these compounds can cause human health and environmental problems, especially regarding to water resources. In this work, a method for multiresidue determination of 62 pesticides in surface water using the rotating disk sorptive extraction (RDSE) technique for sample preparation and ultra-high-performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/IVIS) for analysis was optimized and validated. The parameters time and rotational disk velocity for the extraction step, types and amounts of sorbents, sample pH, ionic strength, time and velocity of the rotating disk in the desorption step, as well different desorption solvents were evaluated. The best results were obtained using 50 mL of sample, acidified at pH 2.0, and 2.5 g of sodium chloride. The selected velocity of rotation in the extraction step was 1600 rpm for 80 min. Inside the disk cavity, a small amount (20 mg) of the polymeric sorbent Oasis (R) HLB was used. The desorption step was performed immerging the disk in 3 mL of methanol and rotating the disk at 1600 rpm for 60 min. Procedural calibration curves showed linearity between 0.05 or 0.1-2 mu g L-1, with r(2) > 0.99 for all compounds. The method presented practical limit of quantification of 0.05 or 0.1 pg L-1 and suitable accuracy and precision, with recoveries from 70.1 to 119.9% and RSD <= 20% for the levels 0.05, 0.1, 0.5 and 2 mu g L-1. The validated method was applied to surface water samples from different river and residues of atrazine, azoxystrobin, clomazone, difenoconazole, epoxiconazole, propoxur, simazine and tebuconazole were found in the range of 0.06-0.35 mu gL(-1). The results indicate that the proposed method is suitable for the determination of pesticide residues in surface water, allowing an easy and simultaneously preparation of several samples with low material consumption. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:54 / 63
页数:10
相关论文
共 52 条
[1]  
[Anonymous], 2015, GUID DOC AN QUAL CON
[2]   Optimisation and validation of a solid-phase microextraction method for simultaneous determination of different types of pesticides in water by gas chromatography-mass spectrometry [J].
Beceiro-Gonzalez, E. ;
Concha-Grana, E. ;
Guimaraes, A. ;
Goncalves, C. ;
Muniategui-Lorenzo, S. ;
Alpendurada, M. F. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1141 (02) :165-173
[3]   Ultra-high-performance liquid chromatography-Time-of-flight high resolution mass spectrometry to quantify acidic drugs in wastewater [J].
Becerra-Herrera, Mercedes ;
Honda, Luis ;
Richter, Pablo .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1423 :96-103
[4]   Peatland as a natural sink for pesticides from no-till systems in subtropical climate [J].
Bortolozo, F. R. ;
Aguiar, Terencio R., Jr. ;
Hansel, F. A. ;
Rosa Filho, E. F. ;
Parron, L. V. ;
Froehner, S. .
AGRICULTURAL WATER MANAGEMENT, 2016, 163 :19-27
[5]   Herbicides in the upper Poxim River, Sergipe, and the risk of contamination of water resources [J].
Britto, Fabio Brandao ;
do Vasco, Anderson Nascimento ;
Pereira, Ana Paula Sousa ;
Mello Junior, Arisvaldo Vieira ;
Nogueire, Luis Carlos .
REVISTA CIENCIA AGRONOMICA, 2012, 43 (02) :390-398
[6]   Past, Present, and Future of Solid Phase Extraction: A Review [J].
Buszewski, Boguslaw ;
Szultka, Malgorzata .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2012, 42 (03) :198-213
[7]   MODERN TECHNIQUES OF SAMPLE PREPARATION FOR PESTICIDE RESIDUES DETERMINATION IN WATER BY LIQUID CHROMATOGRAPHY WITH DETECTION BY DIODE ARRAY AND MASS SPECTROMETRY [J].
Caldas, Sergiane Souza ;
Goncalves, Fabio Ferreira ;
Primel, Ednei Gilberto ;
Prestes, Osmar Damian ;
Martins, Manoel Leonardo ;
Zanella, Renato .
QUIMICA NOVA, 2011, 34 (09) :1604-1617
[8]   Screening and Quantification of 65 Organic Pollutants in Drinking Water by Stir Bar Sorptive Extraction-Gas Chromatography-Triple Quadrupole Mass Spectrometry [J].
Camino-Sanchez, F. J. ;
Zafra-Gomez, A. ;
Ruiz-Garcia, J. ;
Vilchez, J. L. .
FOOD ANALYTICAL METHODS, 2013, 6 (03) :854-867
[9]   A new rotating-disk sorptive extraction mode, with a copolymer of divinylbenzene and N-vinylpyrrolidone trapped in the cavity of the disk, used for determination of florfenicol residues in porcine plasma [J].
Canas, Alejandro ;
Valdebenito, Samuel ;
Richter, Pablo .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (08) :2205-2210
[10]   Solid-phase microextraction using octadecyl-bonded silica immobilized on the surface of a rotating disk: Determination of hexachlorobenzene in water [J].
Canas, Alejandro ;
Richter, Pablo .
ANALYTICA CHIMICA ACTA, 2012, 743 :75-79