BIOMECHANICAL EVALUATION OF LOCKING COMPRESSION PLATE (LCP) VERSUS DYNAMIC COMPRESSION PLATE (DCP): A FINITE ELEMENT ANALYSIS

被引:1
作者
Suaimi, Muhammad Khairul Asyraf [1 ,2 ]
Ab Rashid, Amir Mustakim [1 ,2 ]
Nasution, Ahmad Kafrawi [3 ]
Seng, Gan Hong [4 ]
Kadir, Mohammed Rafiq Abdul [2 ,5 ]
Ramlee, Muhammad Hanif [1 ,2 ]
机构
[1] Univ Teknol Malaysia, Inst Human Ctr Engn iHumEn, Med Devices & Technol Ctr MEDiTEC, Utm Johor Bahru 81310, Johor, Malaysia
[2] Univ Teknol Malaysia, Fac Engn, Sch Biomed Engn & Hlth Sci, Bioinspired Devices & Tissue Engn BIOINSPIRA Res, Utm Johor Bahru 81310, Johor, Malaysia
[3] Muhammadiyah Univ Riau, Fac Engn, Pekanbaru 28291, Riau, Indonesia
[4] Univ Malaysia Kelantan, Dept Data Sci, UMK City Campus, Pengkala Chepa 16100, Kelantan, Malaysia
[5] Univ Teknol Malaysia, Inst Human Ctr Engn iHumEn, Sports Innovat & Technol Ctr SITC, Utm Johor Bahru 81310, Johor, Malaysia
来源
JURNAL TEKNOLOGI-SCIENCES & ENGINEERING | 2022年 / 84卷 / 03期
关键词
Locking Compression Plate; Dynamic Compression Plate; Von Mises Stress; Displacement; tibia; FIXATION; BONE; FRACTURES; STABILITY;
D O I
10.11113/jurnalteknologi.v84.16687
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Internal fixators are commonly used to treat long bone fractures, its aim is to provide interfragmentary compression, allow limited micromotion and provide stability to the bone for ambulation. However, complications such as non-unions, malunions and broken implant, can occur due to the complexity of mechanical force acting on the bone-plate models. Therefore, this study is proposed to investigate the biomechanical characterization of plate design on a tibia bone using finite element method. Two different designs; 1) locking compression plate (LCP) and dynamic compression plate (DCP) were simulated by using Marc.Mentat software. From the findings, the LCP have lower peak von Mises stress (VMS) distribution of 160 MPa compared to DCP with VMS value of 232 MPa. Surprisingly, the VMS of DCP plate system have exceed the yield strength of stainless steel (215 MPa) which translate to higher risk of failures. Moreover, the DCP plate system shows 50% lower stability compared to the LCP plate system, which has the peak displacement at 0.98 mm compared to the DCP bone at 1.53 mm. In conclusion, the LCP provides better stability and stress distribution up to 45% differences as compared to the DCP.
引用
收藏
页码:125 / 131
页数:7
相关论文
共 29 条
  • [1] Anandasivam Nidharshan S, 2017, J Clin Orthop Trauma, V8, P225, DOI 10.1016/j.jcot.2017.07.012
  • [2] A finite element analysis of bone plates available for prophylactic internal fixation of the radial osteocutaneous donor site using the sheep tibia model
    Avery, C. M. E.
    Bujtar, Peter
    Simonovics, Janos
    Dezsi, Tamas
    Varadi, Karoly
    Sandor, George K. B.
    Pan, Jingzhe
    [J]. MEDICAL ENGINEERING & PHYSICS, 2013, 35 (10) : 1421 - 1430
  • [3] Evaluation of bone plate with low-stiffness material in terms of stress distribution
    Benli, Semih
    Aksoy, Sami
    Havitcioglu, Hasan
    Kucuk, Mumin
    [J]. JOURNAL OF BIOMECHANICS, 2008, 41 (15) : 3229 - 3235
  • [4] A simplified application (APP) for the parametric design of screw-plate fixation of bone fractures
    Chung, Chen-Yuan
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 77 : 642 - 648
  • [5] The mode of interfragmentary movement affects bone formation and revascularization after callus distraction
    Claes, Lutz
    Meyers, Nicholaus
    Schuelke, Julian
    Reitmaier, Sandra
    Klose, Svenja
    Ignatius, Anita
    [J]. PLOS ONE, 2018, 13 (08):
  • [6] Epidemiology of inpatient tibia fractures in Singapore - A single centre experience
    Decruz, Joshua
    Rex, Rex Premchand Antony
    Khan, Suheal Ali
    [J]. CHINESE JOURNAL OF TRAUMATOLOGY, 2019, 22 (02) : 99 - 102
  • [7] Early locking plate removal following open reduction and internal fixation of proximal humeral fractures could prevent secondary implant-related complications
    Dimitriou, Dimitris
    Waldmann, Soeren
    Antoniadis, Alexander
    Liebhauser, Martin
    Helmy, Naeder
    Riede, Ulf
    [J]. JOURNAL OF ORTHOPAEDICS, 2020, 17 : 106 - 109
  • [8] FAGELBERG E, 2015, INT BIOMECH, V2, P12
  • [9] Gailani G., 2006, PROC IJME INTERTECH, P204
  • [10] Influence of the number and position of stripped screws on plate-screw construct biomechanical properties
    Garces, Gerardo L.
    Yanez, Alejandro
    Cuadrado, Alberto
    Martel, Oscar
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 : S54 - S59