Validation of an HPLC method on short columns to assay ketoconazole and formaldehyde in shampoo

被引:43
作者
Nguyet, ANM
Tallieu, L
Plaizier-Vercammen, J
Massart, DL
Vander Heyden, Y
机构
[1] Free Univ Brussels, Inst Pharmaceut, Dept Pharmaceut & Biomed Anal, B-1090 Brussels, Belgium
[2] Free Univ Brussels, Inst Pharmaceut, Dept Pharmaceut Technol & Phys Pharm, B-1090 Brussels, Belgium
关键词
short column HPLC; method validation; robustness test; Plackett-Burman design; ketoconazole; formaldehyde;
D O I
10.1016/S0731-7085(02)00640-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An HPLC method to determine simultaneously ketoconazole and formaldehyde in an anti-dandruff shampoo, originally developed on a long column, was transferred to two short columns with similar stationary phase properties, but with a length of at the most 30% of the initial one. Using the conventional column as reference, the fast HPLC methods on the short columns were validated. The validation characteristics consisted of selectivity, linearity range, precision (repeatability and time-different intermediate precision), bias and robustness. For the ketoconazole assay, linearity for peak area was found in the concentration range up to 0.20 mg/ml. For formaldehyde, two calibration ranges (0-10 x 10(-5) and 0-10 x 10(-4)%) were linear, both for peak area and height. The assays for both ketoconazole and formaldehyde in these ranges showed no bias and an acceptable precision, although the precision found with the short columns was slightly worse than with the long one. The robustness tests were performed applying a Plackett-Burman design. For the ketoconazole assay, 6 factors were examined in a 12 experiments design and for formaldehyde, 11 factors in 16 experiments. The methods were found to be robust. Despite the somewhat less good precision the transfer seems to be successful and the obtained assays on the short columns are applicable for fast routine analysis. (C) 2003 Published by Elsevier Science B.V.
引用
收藏
页码:1 / 19
页数:19
相关论文
共 33 条
[1]  
[Anonymous], 1994, ISO 5725-2 Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
[2]  
Association of Official Analytical Chemists, 1984, OFF METH AN
[3]   CORRELATION OF QUANTITATIVE-ANALYSIS PRECISION TO RETENTION TIME PRECISION AND CHROMATOGRAPHIC RESOLUTION FOR RAPID, SHORT COLUMN ANALYSIS [J].
BAHOWICK, TJ ;
SYNOVEC, RE .
ANALYTICAL CHEMISTRY, 1995, 67 (03) :631-640
[4]  
BENASSI CA, 1989, J CHROMATOGR, V464, P387
[5]  
CHAPPELL I, 2000, LC GC, V18, pS35
[6]  
*COUNC EUR, 2002, EUR PHARM
[7]  
Dong M.W., 2000, TODAYS CHEMIST WORK, V9, P46
[8]  
*EUR DEP QUAL MED, 1996, EUR PHARM 1997
[9]  
FLICKINGER B, 1999, PHARM FORMULATIO JAN, P16
[10]   Determination of formaldehyde in liquid, solid and semisolid pharmaceuticals and cosmetics by flow injection-pervaporation [J].
Gámiz-Gracia, L ;
de Castro, MDL .
ANALYST, 1999, 124 (07) :1119-1121