Location of water tree degraded point along XLPE cable line using DC voltage

被引:0
|
作者
Suenaga, Kiyoka [1 ]
Uchida, Katsumi [2 ]
Hozumi, Naohiro [3 ]
机构
[1] JFE Steel Corp, Kurashiki, Okayama 7128024, Japan
[2] Chubu Electr Power Co Inc, Nagoya, Aichi 4598001, Japan
[3] Aichi Inst Technol, Toyota 4700392, Japan
来源
PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS | 2007年
关键词
MV class XLPE cable; water-tree degradation; location; kicking phenomenon; partial discharge;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Until now many diagnosing techniques for water-tree degraded MV class XLPE cables have been proposed. However, although they can detect the average degree of degradation throughout the cable, the degraded part can hardly be located. The maintenance cost will be significantly reduced if the degraded part is located by repairing only the degraded part of the cable. This presentation will introduce a new method to locate the water-tree degraded part along a cable line by applying DC voltage. While DC leakage current measurement is carried out for diagnosing cables degraded by water-tree, it is often observed that the leakage current varies unstably. This phenomenon, called as "kicking", is considered to have a relation with partial discharges accompanied by water-tree. We tried to locate this highly degraded part along the cable length. Using a short size cable, it was proved that partial discharges, accompanied by an electrical tree generated from a water-tree, were taking place. The point was precisely located by using time-domain waveform measurement. Based on the above achievement, an equipment to locate highly degraded part along a cable line was developed. It was proved using a full-scale cable line that the equipment could locate the degraded part with a sufficient precision.
引用
收藏
页码:1224 / +
页数:2
相关论文
共 50 条
  • [1] DC voltage and AC voltage characteristics of current flowing in water tree degraded XLPE cable
    Kamohara H.
    Kudo Y.
    Ehara Y.
    IEEJ Transactions on Fundamentals and Materials, 2018, 138 (09) : 463 - 470
  • [2] Behavior of Residual Charges in Water-tree Degraded XLPE Sheets and Cable
    Ebinuma, Yasumitsu
    Masui, Noriaki
    TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS, 2006, 7 (05) : 224 - 229
  • [3] Electrical Tree Initiation in XLPE Cable Insulation by Application of DC and Impulse Voltage
    Liu Ying
    Cao Xiaolong
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (05) : 1691 - 1698
  • [4] WATER TREE RETARDANT XLPE CABLE USING VLDPE
    ASANO, A
    TAKAHASHI, T
    MAEDA, K
    NIWA, T
    IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (01) : 553 - 558
  • [5] Electrical Tree Growth Characteristics in XLPE Cable Insulation under DC Voltage Conditions
    Liu, Ying
    Cao, Xiaolong
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (06) : 3676 - 3684
  • [6] Investigation of Water Tree Characteristic in XLPE Nanocomposites for Medium Voltage Cable Application
    Wahab, J. A.
    Mansor, Noor Syazwani
    Ishak, D.
    Kamarol, M.
    Mariatti, M.
    Ghani, A. B. A.
    Halim, H. S.
    2017 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND POWER SYSTEMS (ICHVEPS), 2017, : 46 - 50
  • [7] Location of Water Tree Degradation in a Long Polymeric Cable Line
    Kim, Myong Hwan
    Hozumi, Naohiro
    Murakami, Yoshinobu
    Nagao, Masayuki
    Kurihara, Takashi
    Okamoto, Tatsuki
    Tsuji, Taizo
    Uchida, Katsumi
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 141 - 144
  • [8] Correlation between space charge distribution and water-tree location in aged XLPE cable
    Suzuki, K
    Tanaka, Y
    Takada, T
    Ohki, Y
    Takeya, C
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2001, 8 (01) : 78 - 81
  • [9] DEVELOPMENT OF NEW WATER TREE SUPPRESSIVE XLPE CABLE
    WATANABE, K
    YAGYU, H
    SEKII, Y
    MARUMO, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 1986, 1 (01) : 27 - 33
  • [10] Study on Water Tree Degradation Diagnosis of XLPE Cable Using Charge Radar
    Kim, MyonHwan
    Unoki, Taketo
    Murakami, Yoshinobu
    Nagao, Masayuki
    Kurihara, Takashi
    Okamoto, Tatsuki
    Miyajima, Kazuhisa
    Uchida, Katsumi
    Hozumi, Naohiro
    PROCEEDINGS OF 2014 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2014), 2014, : 148 - 151