Isotropic Three-Dimensional T2 Mapping of Knee Cartilage: Development and Validation

被引:22
作者
Colotti, Roberto [1 ,2 ]
Omoumi, Patrick [1 ,2 ]
Bonanno, Gabriele [1 ,2 ,3 ,4 ]
Ledoux, Jean-Baptiste [1 ,2 ,5 ]
van Heeswijk, Ruud B. [1 ,2 ]
机构
[1] Univ Hosp CHUV, Dept Radiol, Lausanne, Switzerland
[2] Univ Lausanne UNIL, Lausanne, Switzerland
[3] Johns Hopkins Univ, Dept Med, Div Cardiol, Baltimore, MD USA
[4] Johns Hopkins Univ, Russell Morgan Dept Radiol & Radiol Sci, Div MR Res, Baltimore, MD USA
[5] Ctr Biomed Imaging CIBM, Lausanne, Switzerland
基金
瑞士国家科学基金会;
关键词
T-2; mapping; isotropic; 3D; knee cartilage; 3T; osteoarthritis; STEADY-STATE DESS; ARTICULAR-CARTILAGE; RELAXATION-TIME; CT ARTHROGRAPHY; DOUBLE ECHO; IN-VIVO; T2; OSTEOARTHRITIS; ACCURACY; MRI;
D O I
10.1002/jmri.25755
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: 1) To implement a higher-resolution isotropic 3D T-2 mapping technique that uses sequential T-2-prepared segmented gradient-recalled echo (Iso3DGRE) images for knee cartilage evaluation, and 2) to validate it both in vitro and in vivo in healthy volunteers and patients with knee osteoarthritis. Materials and Methods: The Iso3DGRE sequence with an isotropic 0.6 mm spatial resolution was developed on a clinical 3T MR scanner. Numerical simulations were performed to optimize the pulse sequence parameters. A phantom study was performed to validate the T-2 estimation accuracy. The repeatability of the sequence was assessed in healthy volunteers (n = 7). T-2 values were compared with those from a clinical standard 2D multislice multiecho (MSME) T-2 mapping sequence in knees of healthy volunteers (n = 13) and in patients with knee osteoarthritis (OA, n = 5). Results: The numerical simulations resulted in 100 excitations per segment and an optimal radiofrequency (RF) excitation angle of 15 degrees. The phantom study demonstrated a good correlation of the technique with the reference standard (slope 0.9 +/- 0.05, intercept 0.2 +/- 1.7 msec, R-2 >= 0.99). Repeated measurements of cartilage T-2 values in healthy volunteers showed a coefficient of variation of 5.6%. Both Iso3DGRE and MSME techniques found significantly higher cartilage T-2 values (P < 0.03) in OA patients. Iso3DGRE precision was equal to that of the MSME T-2 mapping in healthy volunteers, and significantly higher in OA (P = 0.01). Conclusion: This study successfully demonstrated that high-resolution isotropic 3D T-2 mapping for knee cartilage characterization is feasible, accurate, repeatable, and precise. The technique allows for multiplanar reformatting and thus T-2 quantification in any plane of interest.
引用
收藏
页码:362 / 371
页数:10
相关论文
共 40 条
[1]  
[Anonymous], 2004, HDB MRI PULSE SEQUEN, DOI 10.1016/B978-0-12-092861-3.X5000-6
[2]   On the accuracy and precision of cardiac magnetic resonance T2 mapping: A high-resolution radial study using adiabatic T2 preparation at 3T [J].
Bano, Wajiha ;
Feliciano, Helene ;
Coristine, Andrew J. ;
Stuber, Matthias ;
van Heeswijk, Ruud B. .
MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (01) :159-169
[3]  
Bert Jack M, 2007, J Knee Surg, V20, P15
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
BLOCH F, 1946, PHYS REV, V70, P460, DOI 10.1103/PhysRev.70.460
[6]   Relationship between trabecular bone structure and articular cartilage morphology and relaxation times in early OA of the knee joint using parallel MRI at 3 T [J].
Bolbos, R. I. ;
Zuo, Jin ;
Banerjee, Suchandrima ;
Link, Thomas M. ;
Ma, C. Benjamin ;
Li, Xiaojuan ;
Majumdar, Sharmila .
OSTEOARTHRITIS AND CARTILAGE, 2008, 16 (10) :1150-1159
[7]   Self-Navigation with Compressed Sensing for 2D Translational Motion Correction in Free-Breathing Coronary MRI: A Feasibility Study [J].
Bonanno, Gabriele ;
Puy, Gilles ;
Wiaux, Yves ;
van Heeswijk, Ruud B. ;
Piccini, Davide ;
Stuber, Matthias .
PLOS ONE, 2014, 9 (08)
[8]   T2 relaxation time measurements in osteoarthritis [J].
David-Vaudey, E ;
Ghosh, S ;
Ries, M ;
Majumdar, S .
MAGNETIC RESONANCE IMAGING, 2004, 22 (05) :673-682
[9]   T2 relaxation time of cartilage at MR imaging: Comparison with severity of knee osteoarthritis [J].
Dunn, TC ;
Lu, Y ;
Jin, H ;
Ries, MD ;
Majumdar, S .
RADIOLOGY, 2004, 232 (02) :592-598
[10]  
Favre J., 2017, Journal of orthopaedic research