Beam-column tests of cold-formed steel elliptical hollow sections

被引:74
作者
Chen, Man-Tai [1 ,2 ,3 ]
Young, Ben [4 ]
机构
[1] Shanghai Jiao Tong Univ, State Key Lab Ocean Engn, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, Dept Civil Engn, Shanghai 200240, Peoples R China
[3] Univ Hong Kong, Dept Civil Engn, Pokfulam Rd, Hong Kong, Peoples R China
[4] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China
关键词
Beam-columns; Cold-formed steel; Eccentricity; Experiments; Elliptical hollow sections; COMBINED COMPRESSION; STRUCTURAL BEHAVIOR; CHANNEL SECTIONS; DESIGN;
D O I
10.1016/j.engstruct.2019.109911
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental study on cold-formed steel elliptical hollow section (EHS) beam-columns is described in this paper. Forty-two beam-column members with two different specimen lengths were tested at different eccentricities to investigate the load-moment interaction relationship. The initial geometric imperfections were determined before the formal tests. The ultimate load-carrying capacities and full load-displacement responses are presented and discussed. The design of cold-formed steel EHS subjected to compression plus bending is not covered by the current design specifications. Hence, the beam-column strengths derived from the experimental investigation were used to assess the design predictions by incorporating the equivalent diameter method, the equivalent rectangular hollow section approach and the conventional design methods using equivalent diameter for bending and compressive strength predictions with the interaction curves adopted in the current design rules for structural use of steel. The reliability of these design rules was evaluated. The comparisons reveal that the predictions by these design methods are generally quite conservative and reliable for cold-formed steel EHS subjected to compression plus bending, except that the design method incorporating the equivalent rectangular hollow section approach with the interaction relationship specified in European Code is unreliable.
引用
收藏
页数:11
相关论文
共 37 条
[1]  
[Anonymous], 1998, AS4100
[2]  
[Anonymous], 2005, EN199311
[3]  
[Anonymous], 2005, NZS4600 AS
[4]  
ANSI, 2016, AISC360 ANSI
[5]  
Baldassino N, 2018, 8 INT C THIN WALL ST
[6]   EXPERIMENTAL VS. THEORETICAL DESIGN APPROACHES FOR THIN-WALLED COLD-FORMED STEEL BEAM-COLUMNS [J].
Baldassino, Nadia ;
Bernuzzi, Claudio ;
Simoncelli, Marco .
ADVANCED STEEL CONSTRUCTION, 2019, 15 (01) :55-65
[7]   Behavior and design of cold-formed and hot-finished steel elliptical tubular stub columns [J].
Cai, Yancheng ;
Quach, Wai-Meng ;
Chen, Man-Tai ;
Young, Ben .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 156 :252-265
[8]   Bending strength of hot-rolled elliptical hollow sections [J].
Chan, T. M. ;
Gardner, L. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2008, 64 (09) :971-986
[9]   Compressive resistance of hot-rolled elliptical hollow sections [J].
Chan, T. M. ;
Gardner, L. .
ENGINEERING STRUCTURES, 2008, 30 (02) :522-532
[10]  
Chan TM, 2010, P I CIVIL ENG-STR B, V163, P391, DOI 10.1680/stbu.2010.1686.891