Proton therapy coverage for prostate cancer treatment

被引:16
作者
Vargas, Carlos [1 ,2 ]
Wagner, Marcus [1 ]
Mahajan, Chaitali [1 ]
Indelicato, Daniel [2 ]
Fryer, Amber [1 ]
Falchook, Aaron [1 ]
Horne, David [1 ]
Chellini, Angela [1 ]
McKenzie, Craig [1 ]
Lawlor, Paula [1 ]
Li, Zuofeng [1 ]
Lin, Liyong [1 ]
Keole, Sameer [1 ]
机构
[1] Univ Florida, Proton Therapy Inst, Jacksonville, FL 32206 USA
[2] Univ Florida, Coll Med, Dept Radiat Oncol, Gainesville, FL USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2008年 / 70卷 / 05期
关键词
protons; dose-volume; prostate cancer; high dose; motion;
D O I
10.1016/j.ijrobp.2007.09.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine the impact of prostate motion on dose coverage in proton therapy. Methods and Materials: A total of 120 prostate positions were analyzed on 10 treatment plans for 10 prostate patients treated using our low-risk proton therapy prostate protocol (University of Florida Proton Therapy Institute 001). Computed tomography and magnetic resonance imaging T-2-weighted turbo spin-echo scans were registered for all cases. The planning target volume included the prostate with a 5-mm axial and 8-mm superoinferior expansion. The prostate was repositioned using 5- and 10-mm one-dimensional vectors and 10-mm multidimensional vectors (Points A-D). The beam was realigned for the 5- and 10-mm displacements. The prescription dose was 78 Gy equivalent (GE). Results: The mean percentage of rectum receiving 70 Gy (V-70) was 7.9%, the bladder V-70 was 14.0%, and the femoral head/neck V-50 was 0.1%, and the mean pelvic dose was 4.6 GE. The percentage of prostate receiving 78 Gy (V-78) with the 5-mm movements changed by -0.2% (range, 0.006-0.5 %, p > 0.7). However, the prostate V-78 after a 10-mm displacement changed significantly (p < 0.003) with different movements: 3.4% (superior), -5.6% (inferior), and -10.2% (posterior). The corresponding minimal doses were also reduced: 4.5 GE, -4.7 GE, and -11.7 GE (p : 0.003). For displacement points A-D, the clinical target volume V-78 coverage had a large and significant reduction of 17.4 % (range, 13.5-17.4 %, p < 0.001) in V-78 coverage of the clinical target volume. The minimal prostate dose was reduced 33% (25.8 GE), on average, for Points A-D. The prostate minimal dose improved from 69.3 GE to 78.2 GE (p < 0.001) with realignment for 10-mm movements. Conclusion: The good dose coverage and low normal doses achieved for the initial plan was maintained with movements of : 5 rum. Beam realignment improved coverage for 10-mm displacements. (c) 2008 Elsevier Inc.
引用
收藏
页码:1492 / 1501
页数:10
相关论文
共 50 条
  • [31] Focal Therapy for Prostate Cancer: Complications and Their Treatment
    Rakauskas, Arnas
    Marra, Giancarlo
    Heidegger, Isabel
    Kasivisvanathan, Veeru
    Kretschmer, Alexander
    Zattoni, Fabio
    Preisser, Felix
    Tilki, Derya
    Tsaur, Igor
    van den Bergh, Roderick
    Kesch, Claudia
    Ceci, Francesco
    Fankhauser, Christian
    Gandaglia, Giorgio
    Valerio, Massimo
    FRONTIERS IN SURGERY, 2021, 8
  • [32] Protons, Photons, and the Prostate - is There emerging evidence in the Ongoing Discussion on Particle Therapy for the Treatment of Prostate Cancer?
    Schiller, Kilian C.
    Habl, Gregor
    Combs, Stephanie E.
    FRONTIERS IN ONCOLOGY, 2016, 6
  • [33] Morbidity dynamics in proton-photon or photon radiation therapy for locally advanced prostate cancer
    Khmelevsky, Evgeny V.
    Kancheli, Irina N.
    Khoroshkov, Vladimir S.
    Kaprin, Andrey D.
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2018, 23 (01) : 21 - 27
  • [34] Dosimetric uncertainty in prostate cancer proton radiotherapy
    Lin, Liyong
    Vargas, Carlos
    Hsi, Wen
    Indelicato, Daniel
    Slopsema, Roelf
    Li, Zuofeng
    Yeung, Daniel
    Horne, Dave
    Palta, Jatinder
    MEDICAL PHYSICS, 2008, 35 (11) : 4800 - 4807
  • [35] Photodynamic Therapy-Adjunctive Therapy in the Treatment of Prostate Cancer
    Osuchowski, Michal
    Aebisher, David
    Bartusik-Aebisher, Dorota
    Krupka-Olek, Magdalena
    Dynarowicz, Klaudia
    Przygoda, Maria
    Kawczyk-Krupka, Aleksandra
    DIAGNOSTICS, 2022, 12 (05)
  • [36] Coverage-based treatment planning to accommodate delineation uncertainties in prostate cancer treatment
    Xu, Huijun
    Gordon, J. James
    Siebers, Jeffrey V.
    MEDICAL PHYSICS, 2015, 42 (09) : 5435 - 5443
  • [37] Comparative analysis of dose distribution in photon and proton therapy of prostate cancer
    Smyslov A.Yu.
    Konchili I.N.
    Lebedev L.A.
    Khmelevskii E.V.
    Biomedical Engineering, 2006, 40 (5) : 229 - 232
  • [38] Proton therapy for prostate cancer: The initial Loma Linda University experience
    Slater, JD
    Rossi, CJ
    Yonemoto, LT
    Bush, DA
    Jabola, BR
    Levy, RP
    Grove, RI
    Preston, W
    Slater, JM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (02): : 348 - 352
  • [39] Proton therapy for prostate cancer: A review of the rationale, evidence, and current state
    Royce, Trevor J.
    Efstathiou, Jason A.
    UROLOGIC ONCOLOGY-SEMINARS AND ORIGINAL INVESTIGATIONS, 2019, 37 (09) : 628 - 636
  • [40] Value and Perspectives of Proton Radiation Therapy for Limited Stage Prostate Cancer
    Reinhard W. Schulte
    Jerry D. Slater
    Carl J. Rossi Jr.
    James M. Slater
    Strahlentherapie und Onkologie, 2000, 176 : 3 - 8