Reproducibility of pulse wave velocity measurements with phase contrast magnetic resonance and applanation tonometry

被引:18
|
作者
Suever, Jonathan D. [1 ,2 ]
Oshinski, John [1 ,2 ,3 ]
Rojas-Campos, Enrique [4 ]
Huneycutt, David [4 ]
Cardarelli, Francesca [4 ]
Stillman, Arthur E. [3 ,4 ]
Raggi, Paolo [3 ,4 ]
机构
[1] Emory Clin, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30322 USA
[2] Georgia Inst Technol, Atlanta, GA 30322 USA
[3] Emory Clin, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
[4] Emory Clin, Sch Med, Dept Med, Div Cardiol, Atlanta, GA 30322 USA
来源
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING | 2012年 / 28卷 / 05期
基金
美国国家卫生研究院;
关键词
Pulse wave velocity; Applanation tonometry; Cross-correlation; Phase contrast magnetic resonance; AORTIC STIFFNESS; ARTERIAL STIFFNESS; BLOOD-PRESSURE; DISTENSIBILITY; IMPACT; AGE; ATHEROSCLEROSIS; CALCIFICATION; IMPROVEMENT; ELASTICITY;
D O I
10.1007/s10554-011-9929-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Increased aortic pulse wave velocity (PWV) results from loss of arterial compliance and is associated with unfavorable outcomes. Applanation tonometry (AT) is the most frequently applied method to assess PWV and deduce aortic compliance. The goal of this study was to compare the reproducibility of PWV measurements obtained with: (1) cross-correlation analysis of phase contrast magnetic resonance (PCMR) velocity data, and (2) applanation tonometry (AT). PWV was measured twice with each modality in 13 normal young volunteers (controls) and 9 older patients who had undergone a CT exam to evaluate coronary artery calcium. The coefficient of variation (CoV) between measurements was computed for each modality. There was no significant difference in PWV values obtained with AT and PCMR in controls or patients. The inter-scan reproducibility of PCMR was superior to AT in the controls (CoV: 3.4 +/- A 2.3% vs. 6.3 +/- A 4.0%, P = 0.03) but not in the older patients (7.4 +/- A 8.0% vs. 9.9 +/- A 9.6%, P = 0.32). PWV values were higher in patients than controls (5.6 +/- A 1.2 vs. 9.7 +/- A 2.8, P = 0.002). PCMR and AT yielded similar values for PWV in patients and volunteers. PCMR showed a superior reproducibility in young subjects but not in older patients.
引用
收藏
页码:1141 / 1146
页数:6
相关论文
共 50 条
  • [31] Determination of brachial artery stiffness prior to vascular access creation: reproducibility of pulse wave velocity assessment
    Bode, Aron S.
    Leermakers, Jaap
    Kroon, J. Wilco
    Brands, Peter
    Planken, R. Nils
    Tordoir, Jan H. M.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 (06) : 2370 - 2376
  • [32] Measurement of pulse wave velocity using magnetic resonance imaging
    Gang, G
    Mark, P
    Cockshott, P
    Foster, J
    Martin, T
    Blyth, K
    Steedman, T
    Elliott, A
    Dargie, H
    Groenning, B
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3684 - 3687
  • [33] Quantification of the pulse wave velocity of the descending aorta using axial velocity profiles from phase-contrast magnetic resonance imaging
    Yu, Hsi- Yu
    Peng, Hsu-Hsia
    Wang, Jaw-Lin
    Wen, Chih-Yung
    Tseng, Wen-Yih Isaac
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (04) : 876 - 883
  • [34] Measurement of pulse wave velocity using pulse wave Doppler ultrasound: Comparison with arterial tonometry
    Jiang, Benyu
    Liu, Baoming
    McNeill, Karen L.
    Chowienczyk, Philip J.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (03): : 509 - 512
  • [35] Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis
    Wilkinson, IB
    Fuchs, SA
    Jansen, IM
    Spratt, JC
    Murray, GD
    Cockcroft, JR
    Webb, DJ
    JOURNAL OF HYPERTENSION, 1998, 16 (12) : 2079 - 2084
  • [36] Comparison of an Oscillometric Method with Cardiac Magnetic Resonance for the Analysis of Aortic Pulse Wave Velocity
    Feistritzer, Hans-Josef
    Reinstadler, Sebastian J.
    Klug, Gert
    Kremser, Christian
    Seidner, Benjamin
    Esterhammer, Regina
    Schocke, Michael F.
    Franz, Wolfgang-Michael
    Metzler, Bernhard
    PLOS ONE, 2015, 10 (01):
  • [37] Validation and Reproducibility of Aortic Pulse Wave Velocity as Assessed With Velocity-Encoded MRI
    Grotenhuis, Heynric B.
    Westenberg, Jos M.
    Steendijk, Paul
    van der Geest, Rob J.
    Ottenkamp, Jaap
    Bax, Jeroen J.
    Jukema, J. Wouter
    de Roos, Albert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) : 521 - 526
  • [38] Oscillometric analysis compared with cardiac magnetic resonance for the assessment of aortic pulse wave velocity in patients with myocardial infarction
    Feistritzer, Hans-Josef
    Klug, Gert
    Reinstadler, Sebastian J.
    Reindl, Martin
    Mayr, Agnes
    Schocke, Michael
    Metzler, Bernhard
    JOURNAL OF HYPERTENSION, 2016, 34 (09) : 1746 - 1751
  • [39] Aortic pulse wave velocity in obesity as assessed by magnetic resonance imaging
    Oliver J Rider
    Upasana Tayal
    Jane M Francis
    Monique Robinson
    James P Byrne
    Kieran Clarke
    Stefan Neubauer
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [40] Pulse wave velocity in real-time cardiac magnetic resonance
    Martin Fasshauer
    Johannes T Kowallick
    Arun Joseph
    Christina Unterberg-Buchwald
    Klaus-Dietmar Merboldt
    Michael Steinmetz
    Jan M Sohns
    Wieland Staab
    Andreas Schuster
    Dirk Voit
    Sebastian Schaetz
    Shoun Zhang
    Jens Frahm
    Joachim Lotz
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)