Reproducibility of pulse wave velocity measurements with phase contrast magnetic resonance and applanation tonometry

被引:18
|
作者
Suever, Jonathan D. [1 ,2 ]
Oshinski, John [1 ,2 ,3 ]
Rojas-Campos, Enrique [4 ]
Huneycutt, David [4 ]
Cardarelli, Francesca [4 ]
Stillman, Arthur E. [3 ,4 ]
Raggi, Paolo [3 ,4 ]
机构
[1] Emory Clin, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30322 USA
[2] Georgia Inst Technol, Atlanta, GA 30322 USA
[3] Emory Clin, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
[4] Emory Clin, Sch Med, Dept Med, Div Cardiol, Atlanta, GA 30322 USA
来源
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING | 2012年 / 28卷 / 05期
基金
美国国家卫生研究院;
关键词
Pulse wave velocity; Applanation tonometry; Cross-correlation; Phase contrast magnetic resonance; AORTIC STIFFNESS; ARTERIAL STIFFNESS; BLOOD-PRESSURE; DISTENSIBILITY; IMPACT; AGE; ATHEROSCLEROSIS; CALCIFICATION; IMPROVEMENT; ELASTICITY;
D O I
10.1007/s10554-011-9929-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Increased aortic pulse wave velocity (PWV) results from loss of arterial compliance and is associated with unfavorable outcomes. Applanation tonometry (AT) is the most frequently applied method to assess PWV and deduce aortic compliance. The goal of this study was to compare the reproducibility of PWV measurements obtained with: (1) cross-correlation analysis of phase contrast magnetic resonance (PCMR) velocity data, and (2) applanation tonometry (AT). PWV was measured twice with each modality in 13 normal young volunteers (controls) and 9 older patients who had undergone a CT exam to evaluate coronary artery calcium. The coefficient of variation (CoV) between measurements was computed for each modality. There was no significant difference in PWV values obtained with AT and PCMR in controls or patients. The inter-scan reproducibility of PCMR was superior to AT in the controls (CoV: 3.4 +/- A 2.3% vs. 6.3 +/- A 4.0%, P = 0.03) but not in the older patients (7.4 +/- A 8.0% vs. 9.9 +/- A 9.6%, P = 0.32). PWV values were higher in patients than controls (5.6 +/- A 1.2 vs. 9.7 +/- A 2.8, P = 0.002). PCMR and AT yielded similar values for PWV in patients and volunteers. PCMR showed a superior reproducibility in young subjects but not in older patients.
引用
收藏
页码:1141 / 1146
页数:6
相关论文
共 50 条
  • [21] Reproducibility of regional pulse-wave velocity in uremic subjects
    Di Iorio, Biagio R.
    Cucciniello, Emanuele
    Alinei, Pietro
    Torraca, Serena
    HEMODIALYSIS INTERNATIONAL, 2010, 14 (04) : 441 - 446
  • [22] Brachial-Ankle Pulse Wave Velocity as a Screen for Arterial Stiffness: A Comparison with Cardiac Magnetic Resonance
    Kim, Eun Kyoung
    Chang, Sung-A
    Jang, Shin Yi
    Choi, Ki Hong
    Huh, Eun Hee
    Kim, Jung Hyun
    Kim, Sung Mok
    Choe, Yeon Hyeon
    Kim, Duk-Kyung
    YONSEI MEDICAL JOURNAL, 2015, 56 (03) : 617 - 624
  • [23] Applanation Tonometry in Mice A Novel Noninvasive Technique to Assess Pulse Wave Velocity and Arterial Stiffness
    Leloup, Arthur J. A.
    Fransen, Paul
    Van Hove, Cor E.
    Demolder, Marc
    De Keulenaer, Gilles W.
    Schrijvers, Dorien M.
    HYPERTENSION, 2014, 64 (01) : 195 - 200
  • [24] Measurement of pulse wave velocity in normal ageing: comparison of Vicorder and magnetic resonance phase contrast imaging
    Jehill D. Parikh
    Kieren G. Hollingsworth
    Vijay Kunadian
    Andrew Blamire
    Guy A. MacGowan
    BMC Cardiovascular Disorders, 16
  • [25] Noninvasive evaluation of varying pulse pressures in vivo using brachial sphymomanometry, applanation tonometry, and Pulse Wave Ultrasound Manometry
    Li, Ronny X.
    Ip, Ada
    Sanz-Miralles, Elena
    Konofagou, Elisa E.
    ARTERY RESEARCH, 2017, 18 : 22 - 28
  • [26] Reproducibility of sequential ambulatory blood pressure and pulse wave velocity measurements in normotensive and hypertensive individuals
    Keehn, Louise
    Hall, Wendy L.
    Berry, Sarah E.
    Sanders, Thomas A. B.
    Chowienczyk, Phil
    Floyd, Christopher N.
    JOURNAL OF HYPERTENSION, 2022, 40 (12) : 2528 - 2537
  • [27] The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography
    Siebenhofer, A
    Kemp, CRW
    Sutton, AJ
    Williams, B
    JOURNAL OF HUMAN HYPERTENSION, 1999, 13 (09) : 625 - 629
  • [28] The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography
    A Siebenhofer
    CRW Kemp
    AJ Sutton
    B Williams
    Journal of Human Hypertension, 1999, 13 : 625 - 629
  • [29] APPLANATION TONOMETRY-DERIVED SUBENDOCARDIAL VIABILITY RATIO, AND NOT PULSE WAVE VELOCITY, IS A DETERMINANT FACTOR OF LEFT VENTRICULAR HYPERTROPHY IN HYPERTENSION
    Rodilla, E.
    Costa, J. A.
    Perez-Lahiguera, F.
    Gonzalez, C.
    Herzig, K. H.
    Pascual, J. M.
    JOURNAL OF HYPERTENSION, 2009, 27 : S318 - S318
  • [30] Comparison by Magnetic Resonance Phase Contrast Imaging of Pulse-Wave Velocity in Patients With Single Ventricle Who Have Reconstructed Aortas Versus Those Without
    Fogel, Mark A.
    Li, Christine
    Nicolson, Susan C.
    Spray, Thomas L.
    Gaynor, J. William
    Fuller, Stephanie
    Keller, Marc S.
    Harris, Matthew A.
    Yoganathan, Ajit P.
    Whitehead, Kevin K.
    AMERICAN JOURNAL OF CARDIOLOGY, 2014, 114 (12): : 1902 - 1907