Improvement of the signal-to-noise ratio in interferometry using multi-frame high-dynamic-range and normalization algorithms

被引:7
|
作者
Restrepo, Rene [1 ]
Uribe-Patarroyo, Nestor [1 ]
Belenguer, Tomas [1 ]
机构
[1] Inst Nacl Tecn Aeroespacial INTA, Lab Nacl Instrumentac Espacial LINES, E-28850 Madrid, Spain
关键词
High dynamic range (HDR); Normalization; Fringe analysis; Liquid crystals (LC); CRYSTAL VARIABLE RETARDERS;
D O I
10.1016/j.optcom.2011.10.077
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Using both high dynamic range (HDR) and normalization methodologies, we show a method to improve the fringe pattern contrast in interferometric measurements normally used for phase recovering. In a simulated interferogram that mimics the main effects that can be found in an interferometric process (stray-light, photon noise, electronic noise, scattering phenomena, etc.) it was possible to improve the contrast of the fringes and to decrease the root mean square error by more than 35%. The method proposed is applied to experimental interferograms to measure wavefront error and retardance changes on liquid crystal (LC) devices. It is done by using a Mach-Zehnder set-up in which we used different polarization areas. The proposed method increases the quality of the phase recovered and decreases the root mean square error by 50%. (C) 2011 Elsevier B.V. All rights reserved.