Occlusal Caries Depth Measurements Obtained by Five Different Imaging Modalities

被引:29
作者
Kamburoglu, Kivanc [1 ]
Kurt, Hakan [1 ]
Kolsuz, Eray [1 ]
Oztas, Bengi [1 ]
Tatar, Ilkan [2 ]
Celik, Hakan Hamdi [2 ]
机构
[1] Ankara Univ, Fac Dent, Dept Oral & Maxillofacial Radiol, TR-06100 Ankara, Turkey
[2] Hacettepe Univ, Fac Med, Dept Anat, Ankara, Turkey
关键词
Occlusal caries; Depth measurement; CBCT; Micro-CT; Radiography; BEAM COMPUTED-TOMOGRAPHY; IN-VITRO; DIAGNOSTIC-ACCURACY; LASER FLUORESCENCE; VISUAL INSPECTION; DIGITAL IMAGES; ICDAS-II; SURFACES; REPRODUCIBILITY; RADIOGRAPHY;
D O I
10.1007/s10278-010-9355-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The study aimed to assess the accuracy and reproducibility of occlusal caries depth measurements obtained from different imaging modalities. The study comprised 21 human mandibular molar teeth with occlusal caries. Teeth were imaged using film, CCD, two different cone-beam computerized tomography (CBCT) units and a microcomputer tomography (micro-CT). Thereafter, each tooth was serially sectioned, and the section with the deepest carious lesion was scanned using a high-resolution scanner. Each image set was separately viewed by three oral radiologists. Images were viewed randomly, and each set was viewed twice. Lesion depth was measured on film images using a digital caliper, on CCD and CBCT images using built-in measurement tools, on micro-CT images using the Mimics software program, and on histological images using AxioVision Rel. 4.7. Intra- and inter-rater reliabilities were assessed according to the Bland/Altman method by calculating Intraclass Correlation Coefficients (ICCs). Mean/median values obtained with intraoral systems were lower than those obtained with 3-D and histological images for all observers and both readings. Intra-observer ICC values for all observers were highest for histology and micro-CT. In addition, intra-observer ICC values were higher for histology and CBCT than for histology and intra-oral methods. Inter-observer ICC values for first and second readings were high for all observers. No differences in repeatability were found between Accuitomo and Iluma CBCT images or between intra-oral film and CCD images. Micro-CT was found to be the best imaging method for the ex vivo measurement of occlusal caries depth. In addition, both CBCT units performed similarly and better than intra-oral modalities.
引用
收藏
页码:804 / 813
页数:10
相关论文
共 31 条
[1]   Performance of Laser Fluorescence for Detection of Occlusal Dentinal Caries Lesions in Permanent Molars: An in vivo Study with Total Validation of the Sample [J].
Abalos, C. ;
Herrera, M. ;
Jimenez-Planas, A. ;
Llamas, R. .
CARIES RESEARCH, 2009, 43 (02) :137-141
[2]  
ADE AN, 2010, DENT MATER, V26, P579
[3]   Accuracy of proximal caries depth measurements:: Comparison between limited cone beam computed tomography, storage phosphor and film radiography [J].
Akdeniz, B. Guniz ;
Grondahl, Hans-Goran ;
Magnusson, Bengt .
CARIES RESEARCH, 2006, 40 (03) :202-207
[4]   Three-dimensional study of human dental fissure enamel by synchrotron X-ray microtomography [J].
Dowker, Stephanie E. P. ;
Elliott, James C. ;
Davis, Graham R. ;
Wilson, Rory M. ;
Cloetens, Peter .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2006, 114 :353-359
[5]   Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions [J].
Haiter-Neto, F. ;
Wenzel, A. ;
Gotfredsen, E. .
DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (01) :18-22
[6]   DIAGNOdent measurements and correlation with the depth and volume of minimally invasive cavity preparations [J].
Hamilton, J. C. ;
Gregory, W. A. ;
Valentine, J. B. .
OPERATIVE DENTISTRY, 2006, 31 (03) :291-296
[7]   Clinical and laboratory radiographic caries diagnosis. A study of the same teeth [J].
Hintze, H ;
Wenzel, A .
DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (03) :115-118
[8]   Reproducibility and accuracy of the ICDAS-II for detection of occlusal caries in vitro [J].
Jablonski-Momeni, A. ;
Stachniss, V. ;
Ricketts, D. N. ;
Heinzel-Gutenbrunner, M. ;
Pieper, K. .
CARIES RESEARCH, 2008, 42 (02) :79-87
[9]   Occlusal caries: Evaluation of direct microscopy versus digital imaging used for two histological classification systems [J].
Jablonski-Momeni, Anahita ;
Ricketts, David N. J. ;
Stachniss, Vitus ;
Maschka, Regina ;
Heinzel-Gutenbrunner, Monika ;
Pieper, Klaus .
JOURNAL OF DENTISTRY, 2009, 37 (03) :204-211
[10]   Quantitative measurements obtained by micro-computed tomography and confocal laser scanning microscopy [J].
Kamburoglu, K. ;
Barenboim, S. F. ;
Arituerk, T. ;
Kaffe, I. .
DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (07) :385-391