Dual mobility cemented cups have low dislocation rates in THA revisions

被引:134
作者
Langlais, Frantz L. [1 ]
Ropars, Mickael [1 ]
Gaucher, Francois [1 ]
Musset, Thierry [1 ]
Chaix, Olivier [1 ]
机构
[1] Univ Hosp, F-35203 Rennes, France
关键词
D O I
10.1007/s11999-007-0047-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
THA revisions using standard cups are at risk of dislocation (5.1% to 14.4% incidence), especially in patients over 70 years of age. Constrained tripolar cups have reduced this risk (6% incidence) but are associated with substantial loosening rates (9%). The nonconstrained dual mobility cup was designed to improve prosthetic stability (polyethylene head ! 40 mm diameter) without increasing loosening rates by reducing wear and limiting impingement (rotation range of 108 degrees). We implanted 88 cemented dual mobility cups for THA revisions in 82 patients at high risk of dislocation. Average patient age was 72 years (range, 65-86 years). Eighty-five of the 88 hips were reviewed at 2 to 5 years followup. One patient (1.1%) had a traumatic dislocation at 2 years postoperatively. Two patients (2.3%) had asymptomatic early loosening and three patients (3.5%) had localized radiographic lucencies. These results confirm those with press-fit dual mobility cups suggesting a low dislocation rate at 5 years and a cup survival of 94.6%. At middle term followup, cemented dual mobility cup achieved better results than constrained cups in cases at risk of dislocation and recurrent loosening.
引用
收藏
页码:389 / 395
页数:7
相关论文
共 36 条
  • [1] Dual articulation retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants
    Adam, P
    Farizon, F
    Fessy, MH
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2005, 91 (07): : 627 - 636
  • [2] Dislocationm after revision total hip arthroplasty - An analysis of risk factors and treatment options
    Alberton, GM
    High, WA
    Morrey, BF
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10) : 1788 - 1792
  • [3] Beaulé PE, 2003, REV CHIR ORTHOP, V89, P242
  • [4] A constrained device with increased range of motion prevents early dislocation
    Berend, Keith R.
    Lombardi, Adolph V., Jr.
    Welch, Michael
    Adams, Joanne B.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (447) : 70 - 75
  • [5] The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty - Examining the successes and failures
    Berend, KR
    Lombardi, AV
    Mallory, TH
    Adams, JB
    Russell, JH
    Groseth, KL
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (07) : 93 - 102
  • [6] Use of constrained acetabular components for hip instability: An average 10-year follow-up study
    Bremner, BRB
    Goetz, DD
    Callaghan, JJ
    Capello, WN
    Johnston, RC
    [J]. JOURNAL OF ARTHROPLASTY, 2003, 18 (07) : 131 - 137
  • [7] BRYTROM S, 2003, ACTA ORTHOP SCAND, V74, P514
  • [8] Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty
    Callaghan, JJ
    O'Rourke, MR
    Goetz, DA
    Lewallen, DG
    Johnston, RC
    Capello, WN
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) : 117 - 123
  • [9] Early failure mechanisms of constrained tripolar acetabular sockets used in revision total hip arthroplasty
    Cooke, CC
    Hozack, W
    Lavernia, C
    Sharkey, P
    Shastri, S
    Rothman, RH
    [J]. JOURNAL OF ARTHROPLASTY, 2003, 18 (07) : 827 - 833
  • [10] Biomechanics of large femoral heads - What they do and don't do
    Crowninshield, RD
    Maloney, WJ
    Wentz, DH
    Humphrey, SM
    Blanchard, CR
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) : 102 - 107