Outcomes Following Different Fixation Strategies of Neer Type IIB Distal Clavicle Fractures

被引:7
|
作者
Gutman, Michael J. [1 ]
Joyce, Christopher D. [1 ]
Patel, Manan S. [1 ]
Lazarus, Mark D. [1 ]
Horneff, John G. [1 ]
机构
[1] Thomas Jefferson Univ, Rothman Inst, Philadelphia, PA 19107 USA
来源
ARCHIVES OF BONE AND JOINT SURGERY-ABJS | 2022年 / 10卷 / 02期
关键词
Clavicle fracture; Neer IIB distal clavicle fracture; Acromioclavicular separation; Hook plate; Locking plate; Bosworth screw; Suture repair; LOCKING PLATE; HOOK-PLATE; SCREW FIXATION;
D O I
10.22038/ABJS.2021.54472.2718
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Multiple surgical techniques for fixation of Neer type IIB distal clavicle fractures have been described without consensus on optimal treatment. The purpose of this study is to compare functional and radiographic results with surgical management of Neer type IIB distal clavicle fractures at a single institution. Methods: Sixty-three patients with acute Neer type IIB fractures treated operatively were evaluated. Patients with a minimum of two year follow up were included. Functional scores included American Shoulder and Elbow Surgeons (ASES), Single Assessment Numeric Evaluation (SANE), Simple Shoulder Test (SST), and Likert patient satisfaction (1 to 5). Radiographs were assessed for osseous union and coracoclavicular (CC) distance. Results: Thirty-eight patients met inclusion with a mean follow-up of 5.3 years. Patients were divided into five groups based on fixation technique: suture-only CC fixation (n=6), CC screw fixation only (n=3), open reduction internal fixation (OR IF) without CC fixation (n=8), hook plate fixation (n=4), and ORIF with suture CC reconstruction (n=17). Outcome scores for the entire cohort were 91.8 for ASES, 90.2 for SANE, and 10.8 for STT. Patients with hook plates had significantly lower SANE score (p=0.016), but no other significant differences in functional, satisfaction, or radiographic outcomes were found between groups. Sixteen patients (42.1%) required reoperation. Conclusion: Treatment of Neer type IIB fractures via suture- only fixation, plate-only fixation, or a combination of both demonstrated satisfactory mid to long term outcomes. While implant removal was more common in the CC screw and ORIF groups, no fixation technique proved functionally superior.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 50 条
  • [41] Results of minimal invasive coracoclavicular fixation by double button lift-up system in Neer type II distal clavicle fractures
    Dedeoglu, Suleyman Semih
    Imren, Yunus
    Cabuk, Haluk
    Cakar, Murat
    Arslan, Samet Murat
    Esenyel, Cem Zeki
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (01)
  • [42] Autologous Semitendinosus Tendon Mediated Stabilization of The Coracoclavicular Space Results in Union and Excellent Functional Outcomes in Neer's Type II Distal Clavicle Fractures: A Preliminary Report
    Nema, S. Kumar
    Udayakumar, D.
    Balaji, G.
    Gandhi, S. B.
    Pasupathy, P.
    Prabu, M.
    MLTJ-MUSCLES LIGAMENTS AND TENDONS JOURNAL, 2021, 11 (01): : 69 - 76
  • [43] An alternative fixation method for the treatment of unstable distal clavicle fractures: locked distal radius plate
    Daglar, Buelent
    Delialioglu, Oender M.
    Minareci, Emre
    Tasbas, Buelent A.
    Bayrakci, Kenan
    Gunel, Ugur
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (04) : 324 - 330
  • [44] Outcomes after locking plate fixation of distal clavicle fractures with and without coracoclavicular ligament augmentation
    Brett P. Salazar
    Michael J. Chen
    Julius A. Bishop
    Michael J. Gardner
    European Journal of Orthopaedic Surgery & Traumatology, 2021, 31 : 473 - 479
  • [45] Treatment for unstable distal clavicle fractures (Neer 2) with locking T-plate and additional PDS cerclage
    Martetschlaeger, Frank
    Kraus, Tobias M.
    Schiele, Clara Sophie
    Sandmann, Gunther
    Siebenlist, Sebastian
    Braun, Karl F.
    Stoeckle, Ulrich
    Freude, Thomas
    Neumaier, Markus
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (05) : 1189 - 1194
  • [46] Comparing the Efficacy of Anatomical Locked Plate Fixation with Coracoclavicular Ligament Augmentation to Hook Plate Fixation in Treating Distal Clavicle Fractures
    Wang, Xin
    Fang, Xue
    Qi, Baiwen
    Xiao, Weidong
    Pan, Zhenyu
    Xie, Zhe
    ORTHOPAEDIC SURGERY, 2022, 14 (12) : 3358 - 3366
  • [47] Functional Outcomes Following Bridge Plate Fixation for Distal Radius Fractures
    Lauder, Alexander
    Agnew, Sonya
    Bakri, Karim
    Allan, Christopher H.
    Hanel, Douglas P.
    Huang, Jerry I.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (08): : 1554 - 1562
  • [48] Percutaneous fixation in fractures of the distal third of the clavicle: simpler, cheaper, better
    Oguz Cebesoy
    International Orthopaedics, 2007, 31 : 129 - 129
  • [49] A biomechanical comparison of four different fixation methods for midshaft clavicle fractures
    Chen, Yang
    Yang, Yang
    Ma, Xinlong
    Xu, Weiguo
    Ma, Jianxiong
    Zhu, Shaowen
    Ma, Baoyi
    Xing, Dan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (01) : 13 - 19
  • [50] Distal Clavicle Fractures: Open Reduction and Internal Fixation With a Hook Plate
    Kirsch, Jacob M.
    Blum, Laura
    Hake, Mark E.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 : S2 - S3