Outcomes Following Different Fixation Strategies of Neer Type IIB Distal Clavicle Fractures

被引:7
|
作者
Gutman, Michael J. [1 ]
Joyce, Christopher D. [1 ]
Patel, Manan S. [1 ]
Lazarus, Mark D. [1 ]
Horneff, John G. [1 ]
机构
[1] Thomas Jefferson Univ, Rothman Inst, Philadelphia, PA 19107 USA
来源
ARCHIVES OF BONE AND JOINT SURGERY-ABJS | 2022年 / 10卷 / 02期
关键词
Clavicle fracture; Neer IIB distal clavicle fracture; Acromioclavicular separation; Hook plate; Locking plate; Bosworth screw; Suture repair; LOCKING PLATE; HOOK-PLATE; SCREW FIXATION;
D O I
10.22038/ABJS.2021.54472.2718
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Multiple surgical techniques for fixation of Neer type IIB distal clavicle fractures have been described without consensus on optimal treatment. The purpose of this study is to compare functional and radiographic results with surgical management of Neer type IIB distal clavicle fractures at a single institution. Methods: Sixty-three patients with acute Neer type IIB fractures treated operatively were evaluated. Patients with a minimum of two year follow up were included. Functional scores included American Shoulder and Elbow Surgeons (ASES), Single Assessment Numeric Evaluation (SANE), Simple Shoulder Test (SST), and Likert patient satisfaction (1 to 5). Radiographs were assessed for osseous union and coracoclavicular (CC) distance. Results: Thirty-eight patients met inclusion with a mean follow-up of 5.3 years. Patients were divided into five groups based on fixation technique: suture-only CC fixation (n=6), CC screw fixation only (n=3), open reduction internal fixation (OR IF) without CC fixation (n=8), hook plate fixation (n=4), and ORIF with suture CC reconstruction (n=17). Outcome scores for the entire cohort were 91.8 for ASES, 90.2 for SANE, and 10.8 for STT. Patients with hook plates had significantly lower SANE score (p=0.016), but no other significant differences in functional, satisfaction, or radiographic outcomes were found between groups. Sixteen patients (42.1%) required reoperation. Conclusion: Treatment of Neer type IIB fractures via suture- only fixation, plate-only fixation, or a combination of both demonstrated satisfactory mid to long term outcomes. While implant removal was more common in the CC screw and ORIF groups, no fixation technique proved functionally superior.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 50 条
  • [31] Comparative analysis of locking plate versus hook plate osteosynthesis of Neer type IIB lateral clavicle fractures
    Benjamin Erdle
    Kaywan Izadpanah
    Martin Jaeger
    Patrizia Jensen
    Lukas Konstantinidis
    Jörn Zwingmann
    Norbert P. Südkamp
    Dirk Maier
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 651 - 662
  • [32] Clavicle hook plate fixation for displaced lateral-third clavicle fractures (Neer type II): a functional outcome study
    Good, Daniel W.
    Lui, Darren F.
    Leonard, Michael
    Morris, Seamus
    McElwain, John P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (08) : 1045 - 1048
  • [33] Comparison of four different internal fixation methods in the treatment of distal clavicle fractures
    Li, Liang
    Wu, Hongxiao
    Jiang, Peichao
    Han, Xiaochuan
    Chen, Shiyuan
    Yu, Xuezhong
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2020, 19 (01) : 451 - 458
  • [34] Displaced Neer Type IIB distal-third clavicle fractures—Long-term clinical outcome after plate fixation and additional screw augmentation for coracoclavicular instability
    Thomas M. Tiefenboeck
    Sandra Boesmueller
    Harald Binder
    Adam Bukaty
    Michael M. Tiefenboeck
    Julian Joestl
    Marcus Hofbauer
    Roman C. Ostermann
    BMC Musculoskeletal Disorders, 18
  • [35] Displaced Neer Type IIB distal-third clavicle fractures-Long-term clinical outcome after plate fixation and additional screw augmentation for coracoclavicular instability
    Tiefenboeck, Thomas M.
    Boesmueller, Sandra
    Binder, Harald
    Bukaty, Adam
    Tiefenboeck, Michael M.
    Joestl, Julian
    Hofbauer, Marcus
    Ostermann, Roman C.
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18 : 1 - 6
  • [36] Different internal fixation methods for unstable distal clavicle fractures in adults: a systematic review and network meta-analysis
    Xu, Yinglong
    Guo, Xiaobo
    Peng, Hui
    Dai, Hai
    Huang, Zonggui
    Zhao, Jinmin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [37] Predictors of Persistent Pain After Fixation of Distal Clavicle Fractures in an Active Military Population
    Lanier, Paul J.
    Speirs, Joshua
    Koehler, Logan
    Bader, Julia
    Abdeldawad, Amr
    Waterman, Brian R.
    ORTHOPEDICS, 2018, 41 (01) : E117 - E126
  • [38] Classifications in Brief: The Modified Neer Classification for Distal-third Clavicle Fractures
    Stenson, James
    Baker, William
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2021, 479 (01) : 205 - 209
  • [39] Comparative analysis of locking plates versus hook plates in the treatment of Neer type II distal clavicle fractures
    Wang, Hong-Kai
    Liang, Li-Sheng
    He, Ren-Gao
    Su, Yu-Bin
    Mao, Peng
    Hu, Jun-Zu
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (04)
  • [40] Arthroscopic stabilization for Neer type 2 fracture of the distal clavicle fracture
    Takase, Katsumi
    Kono, Ryohei
    Yamamoto, Kengo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (03) : 399 - 403