Thermodynamic optimisation for open regenerated inverse Brayton cycle (refrigeration/heat pump cycle) Part 2 - performance optimisation

被引:7
作者
Zhang, W. [1 ,2 ]
Chen, L. [1 ]
Sun, F. [1 ]
机构
[1] Naval Univ Engn, Postgrad Sch, Wuhan 430033, Peoples R China
[2] China Satellite Maritime Tracking & Controlling D, Jiangyin 214431, Peoples R China
基金
中国国家自然科学基金;
关键词
Finite time thermodynamics; Pressure drop; Regenerated; Refrigeration cycle; Heat pump cycle; Optimisation; TURBINE POWER-PLANT; EFFICIENCY OPTIMIZATION; FLUID-FLOW; ROAD TRANSPORT; AIR; SYSTEM;
D O I
10.1179/1743967112Z.00000000017
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The thermodynamic performances for the model established in Part 1 of this paper are optimised by adjusting the mass flowrate. When the optimisation is performed with the constraints of the fixed power input and the plant size, the coefficient of performance can be maximised again by properly allocating the fixed flow area among the compressor inlet and the expander outlet. The coefficient of performance of refrigeration can be maximised again by properly allocating the fixed heat conductance inventory among the hot and cold side exchangers and the regenerator. The obtained maxima reach its maxima at optimal compressor pressure ratio. When the heat conductance distribution of the regenerator is fixed for the heat pump, the coefficient of performance can be maximised again by properly allocating the fixed heat conductance inventory between the hot and cold side exchangers. The obtained maxima reach its maxima at optimal compressor pressure ratio.
引用
收藏
页码:96 / 102
页数:7
相关论文
共 27 条