Determination of benzothiazoles and benzotriazoles by using ionic liquid stationary phases in gas chromatography mass spectrometry. Application to their characterization in wastewaters

被引:49
作者
Dominguez, Carmen [1 ]
Reyes-Contreras, Carolina [1 ]
Bayona, Josep M. [1 ]
机构
[1] IDAEA CSIC, Dept Environm Chem, E-08034 Barcelona, Spain
关键词
Ionic liquids; Stationary phases; Wastewater; Benzothiazoles; Benzotriazoles; GC-MS; MUNICIPAL WASTE-WATER; CORROSION-INHIBITORS; SAMPLES; CONTAMINANTS; DERIVATIVES; EXTRACTION; SOLVENTS;
D O I
10.1016/j.chroma.2012.01.054
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Benzothiazoles (BTHs) and benzotriazoles (BTRs) belong to a high production volume chemicals widely used in both industrial and household applications. Since they are recalcitrant to biodegradation, they are widespread in the environment. However, the BTHs and BTRs determination in environmental matrices is hindered by the coelution with coextracted organic matter and the poor selectivity in mass spectrometry due to the low mass of their diagnostic ions. Accordingly, this study examines the selectivity and suitability of new commercially available ionic liquid (IL) stationary phases for GC-MS and their application to the determination of BTHs and BTRs in wastewater samples. Five different IL columns were tested and the best results in terms of resolution, peak symmetry and analysis time were obtained with the SLB-IL59. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:117 / 122
页数:6
相关论文
共 39 条
[1]   2-HYDRAZINO-6-METHYL-BENZOTHIAZOLE AS AN EFFECTIVE INHIBITOR FOR THE CORROSION OF MILD-STEEL IN ACIDIC SOLUTIONS [J].
AJMAL, M ;
MIDEEN, AS ;
QURAISHI, MA .
CORROSION SCIENCE, 1994, 36 (01) :79-84
[2]   Ionic liquids in analytical chemistry [J].
Anderson, Jared L. ;
Armstrong, Daniel W. ;
Wei, Guor-Tzo .
ANALYTICAL CHEMISTRY, 2006, 78 (09) :2892-2902
[3]   High-stability ionic liquids. A new class of stationary phases for gas chromatography [J].
Anderson, JL ;
Armstrong, DW .
ANALYTICAL CHEMISTRY, 2003, 75 (18) :4851-4858
[4]   Immobilized ionic liquids as high-selectivity/high-temperature/high-stability gas chromatography stationary phases [J].
Anderson, JL ;
Armstrong, DW .
ANALYTICAL CHEMISTRY, 2005, 77 (19) :6453-6462
[5]  
BROWNLEE BG, 1992, ENVIRON TOXICOL CHEM, V11, P1153, DOI [10.1897/1552-8618(1992)11[1153:AECOTA]2.0.CO
[6]  
2, 10.1002/etc.5620110812]
[7]   Isolation and characterization of microtox(R)-active components from aircraft de-icing/anti-icing fluids [J].
Cancilla, DA ;
Holtkamp, A ;
Matassa, L ;
Fang, XC .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1997, 16 (03) :430-434
[8]   Chiral ionic liquids as stationary phases in gas chromatography [J].
Ding, J ;
Welton, T ;
Armstrong, DW .
ANALYTICAL CHEMISTRY, 2004, 76 (22) :6819-6822
[9]   Benzotriazole and tolyltriazole as aquatic contaminants. 1. Input and occurrence in rivers and lakes [J].
Giger, Walter ;
Schaffner, Christian ;
Kohler, Hans-Peter E. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (23) :7186-7192
[10]   Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry [J].
Gosetti, Fabio ;
Mazzucco, Eleonora ;
Zampieri, Davide ;
Gennaro, Maria Carla .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (25) :3929-3937