Tricuspid valve repair with the Cosgrove-Edwards annuloplasty system: Early clinical and echo cardiographic results

被引:17
作者
Gatti, G [1 ]
Maffei, G [1 ]
Lusa, AM [1 ]
Pugliese, P [1 ]
机构
[1] Nursing Home Villa Torri, Div Cardiac Surg, Bologna, Italy
关键词
D O I
10.1016/S0003-4975(01)02830-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The use of flexible rings for tricuspid valve repair is becoming popular. The purpose of this study was to evaluate the Cosgrove-Edwards annuloplasty system for tricuspid regurgitation. Methods. From June 1998 to December 2000, 22 patients with significant secondary tricuspid regurgitation underwent tricuspid valve repair with the Cosgrove-Edwards annuloplasty system. All patients had disease of left-sided heart valves in addition to tricuspid disease; 34 concomitant procedures were performed. Twenty-one patients (95.5%) were in preoperative New York Heart Association functional class 3 or 4. The mean follow-up was 19.9 +/- 9.7 months. Results. There were two in-hospital nonvalve-related cardiac deaths (9.1%) and one noncardiac death after discharge (4.5%). All survivors were in New York Heart Association functional class 1 or 2; their tricuspid regurgitation was well controlled within grade 1+ and there was a significant reduction of systolic pulmonary artery pressure. Five (83.3%) of the 6 survivors with preoperative pulmonary hypertension had no or trivial residual tricuspid regurgitation. Conclusions. The Cosgrove-Edwards annuloplasty system is very effective in the treatment of secondary tricuspid regurgitation, also in the presence of pulmonary hypertension. (C) 2001 by The Society of Thoracic Surgeons.
引用
收藏
页码:764 / 767
页数:4
相关论文
共 20 条
[1]  
CARPENTIER A, 1971, J THORAC CARDIOV SUR, V61, P1
[2]  
CARPENTIER A, 1969, PRESSE MED, V77, P251
[3]   Three dimensional reconstruction (shape and motion) of tricuspid annulus in normals and in patients after tricuspid annuloplasty with a flexible ring [J].
Chandra, S ;
Powell, K ;
Breburda, CS ;
Mikic, I ;
Shekhar, R ;
Morehead, A ;
Cosgrove, DM ;
Thomas, JD .
COMPUTERS IN CARDIOLOGY 1996, 1996, :693-696
[4]   INITIAL EXPERIENCE WITH THE COSGROVE-EDWARDS ANNULOPLASTY SYSTEM [J].
COSGROVE, DM ;
ARCIDI, JM ;
RODRIGUEZ, L ;
STEWART, WJ ;
POWELL, K ;
THOMAS, JD .
ANNALS OF THORACIC SURGERY, 1995, 60 (03) :499-504
[5]  
De Vega N G, 1972, Rev Esp Cardiol, V25, P555
[6]  
DELOCHE A, 1974, ARCH MAL COEUR VAISS, V67, P497
[7]  
DEPAULIS R, 1990, J CARDIOVASC SURG, V31, P512
[8]   CLINICAL AND HEMODYNAMIC PERFORMANCE OF A TOTALLY FLEXIBLE PROSTHETIC RING FOR ATRIOVENTRICULAR VALVE RECONSTRUCTION [J].
DURAN, CG ;
UBAGO, JLM .
ANNALS OF THORACIC SURGERY, 1976, 22 (05) :458-463
[9]   Guidelines for reporting morbidity and mortality after cardiac valvular operations [J].
Edmunds, LH ;
Clark, RE ;
Cohn, LH ;
Grunkemeier, GL ;
Miller, C ;
Weisel, RD .
ANNALS OF THORACIC SURGERY, 1996, 62 (03) :932-935
[10]   Cosgrove-Edwards annuloplasty system: Midterm results [J].
Gillinov, AM ;
Cosgrove, DM ;
Shiota, T ;
Qin, JX ;
Tsujino, H ;
Stewart, WJ ;
Thomas, JD ;
Porqueddu, M ;
White, JA ;
Blackstone, EH .
ANNALS OF THORACIC SURGERY, 2000, 69 (03) :717-721