Composite crystallization fouling characteristics of normal solubility salt in double-pipe heat exchanger

被引:48
作者
Lv, Yang [1 ]
Lu, Kai [1 ]
Ren, Yongsheng [1 ]
机构
[1] Ningxia Univ, Natl Demonstrat Ctr Expt Chem Educ, Dept Chem & Chem Engn, State Key Lab High Efficiency Coal Utilizat & Gre, Yinchuan 750021, Ningxia, Peoples R China
关键词
Crystallization fouling; Normal solubility mixed salt; Heat exchanger; Fouling thermal resistance; SCALE DEPOSITION; CACO3; CASO4; PLATE;
D O I
10.1016/j.ijheatmasstransfer.2020.119883
中图分类号
O414.1 [热力学];
学科分类号
摘要
The fouling behavior of normal solubility pure salt (Na2SO4) and mixed salt (Na2SO4 and NaCl) in counter-current double-pipe heat exchanger was investigated. Through real-time monitoring of inlet and outlet temperatures of hot and cold fluids, the influences of various factors such as the inlet temperature, inlet velocity of hot solution and solute mass ratio on the fouling thermal resistance were determined. The results show that the fouling thermal resistance is determined by the sodium sulfate content at the experimental temperature and the change of the solubility of sodium sulfate within the temperature difference of heat transfer. With the increase of the inlet velocity of hot solution, the thermal resistance of fouling decreases gradually, indicating that the fouling process is controlled by chemical kinetics. In the fouling experiment of mixed salt solution, the main deposition material is sodium sulfate. Due to the common ion effect, sodium chloride greatly affects the saturated solubility of sodium sulfate, with the increase of the mass ratio of sodium chloride, the fouling thermal resistance and the fouling rate decreases gradually, and the time when the fouling thermal resistance reaches the asymptotic value is prolonged. The research results can provide theoretical guidance for scale inhibition of cooling surface of double-pipe heat exchanger in the treatment of wastewater containing sodium sulfate. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:8
相关论文
共 28 条
[1]   Transition of convective heat transfer to subcooled flow boiling due to crystallization fouling [J].
Abd-Elhady, M. S. ;
Malayeri, M. R. .
APPLIED THERMAL ENGINEERING, 2016, 92 :122-129
[2]   Roughness and constriction effects on heat transfer in crystallization fouling [J].
Albert, Florian ;
Augustin, Wolfgang ;
Scholl, Stephan .
CHEMICAL ENGINEERING SCIENCE, 2011, 66 (03) :499-509
[3]   Dynamic modelling of Heat Exchanger fouling in multistage flash (MSF) desalination [J].
Alsadaie, Salih M. ;
Mujtaba, Iqbal M. .
DESALINATION, 2017, 409 :47-65
[4]   Comparison of crystallization fouling in plate and double-pipe heat exchangers [J].
Bansal, B ;
Müller-Steinhagen, H ;
Chen, XD .
HEAT TRANSFER ENGINEERING, 2001, 22 (05) :13-25
[5]  
Bohnet M., 1987, CHEM ENG TECHNOL, V10, P113, DOI DOI 10.1002/CEAT.270100115
[6]   Aspects of crystallization fouling [J].
Bott, TR .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1997, 14 (04) :356-360
[7]  
Ding X., 1985, IND CRYSTALLIZATION
[8]  
Epstein N., 1981, Heat Transfer Engineering, V4, P43, DOI [DOI 10.1080/01457638108939594, 10.1080/01457638108939594]
[9]   Chapter 8: Generating knowledge [J].
Eriksson, Tommy ;
Lu, Hao ;
Wiffen, Phil .
EUROPEAN JOURNAL OF HOSPITAL PHARMACY, 2015, 22 (01) :2-6
[10]   Induction Time in Crystallization Fouling on Heat Transfer Surfaces [J].
Geddert, Timo ;
Augustin, Wolfgang ;
Scholl, Stephan .
CHEMICAL ENGINEERING & TECHNOLOGY, 2011, 34 (08) :1303-1310