Draft Proposal of an Optical Cuffless Blood Pressure Device

被引:0
作者
Tamura, Toshiyo [1 ]
机构
[1] Waseda Univ, Tokyo, Japan
关键词
Optical cuffless non-invasive blood pressure monitor; IEEE; ISO; FDA; CE; Regulation; Regulatory science; TIME;
D O I
10.1007/s12553-020-00435-4
中图分类号
R-058 [];
学科分类号
摘要
Optical cuffless non-invasive blood pressure (NIBP) monitoring, including photoplethysmographic sensing calculated based on the pulse transit time (PTT), pulse contour method, and second derivative signal, is a hot topic in home healthcare. However, previous evaluations of cuffless blood pressure revealed issues with accuracy and validation; cuffless measurements are less accurate than intermittent cuff-based sphygmomanometer measurements. Use of an inaccurate device for blood pressure monitoring represents a health risk. To protect device users, standards need to be formulated. We present a draft optical cuffless blood pressure monitor; opinions and comments are cordially invited.
引用
收藏
页码:1129 / 1136
页数:8
相关论文
共 15 条
[1]  
[Anonymous], 2015, Essential Manual of 24 hour Blood Pressure Management: from Morning to Nocturnal Hypertension
[2]  
[Anonymous], 2018, ISO8106022019
[3]  
Baruch Martin C, 2011, Nonlinear Biomed Phys, V5, P1, DOI 10.1186/1753-4631-5-1
[4]   Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010 [J].
Bilo, Grzegorz ;
Zorzi, Cristina ;
Munera, Juan E. Ochoa ;
Torlasco, Camilla ;
Giuli, Valentina ;
Parati, Gianfranco .
BLOOD PRESSURE MONITORING, 2015, 20 (05) :291-294
[5]   A novel cuffless device for self-measurement of blood pressure: concept, performance and clinical validation [J].
Boubouchairopoulou, N. ;
Kollias, A. ;
Chiu, B. ;
Chen, B. ;
Lagou, S. ;
Anestis, P. ;
Stergiou, G. S. .
JOURNAL OF HUMAN HYPERTENSION, 2017, 31 (07) :479-482
[6]   Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration [J].
Chen, W ;
Kobayashi, T ;
Ichikawa, S ;
Takeuchi, Y ;
Togawa, T .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (05) :569-574
[7]   Pulse transit time technique for cuffless unobtrusive blood pressure measurement: from theory to algorithm [J].
Ding, Xiaorong ;
Zhang, Yuan-Ting .
BIOMEDICAL ENGINEERING LETTERS, 2019, 9 (01) :37-52
[8]   On the Analysis of Fingertip Photoplethysmogram Signals [J].
Elgendi, Mohamed .
CURRENT CARDIOLOGY REVIEWS, 2012, 8 (01) :14-25
[9]   Continuous Non-invasive finger cuff CareTaker® comparable to invasive intraarterial pressure in patients undergoing major intra-abdominal surgery [J].
Gratz, Irwin ;
Deal, Edward ;
Spitz, Francis ;
Baruch, Martin ;
Allen, I. Elaine ;
Seaman, Julia E. ;
Pukenas, Erin ;
Jean, Smith .
BMC ANESTHESIOLOGY, 2017, 17
[10]  
Mengyang Liu, 2017, International Journal of Computer Theory and Engineering, V9, P202, DOI 10.7763/IJCTE.2017.V9.1138