A 3D CZT high resolution detector for X- and gamma-ray astronomy

被引:21
作者
Kuvvetli, I. [1 ]
Budtz-Jorgensen, C. [1 ]
Zappettini, A. [2 ]
Zambelli, N. [2 ]
Benassi, G. [2 ]
Kalemci, E. [3 ]
Caroli, E. [4 ]
Stephen, J. B. [4 ]
Auricchio, N. [4 ]
机构
[1] Tech Univ Denmark, DTU Space, Copenhagen, Denmark
[2] CNR, IMEM, I-43100 Parma, Italy
[3] Sabanci Univ, Istanbul, Turkey
[4] INAF, IASF, Bologna, Italy
来源
HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY VI | 2014年 / 9154卷
关键词
3D CZT detectors; CZT Drift Strip Detectors; High Energy Resolution; High Position Resolution; High Efficiency; Position Interpolation;
D O I
10.1117/12.2055119
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
At DTU Space we have developed a high resolution three dimensional (3D) position sensitive CZT detector for high energy astronomy. The design of the 3D CZT detector is based on the CZT Drift Strip detector principle. The position determination perpendicular to the anode strips is performed using a novel interpolating technique based on the drift strip signals. The position determination in the detector depth direction, is made using the DOI technique based the detector cathode and anode signals. The position determination along the anode strips is made with the help of 10 cathode strips orthogonal to the anode strips. The position resolutions are at low energies dominated by the electronic noise and improve therefore with increased signal to noise ratio as the energy increases. The achievable position resolution at higher energies will however be dominated by the extended spatial distribution of the photon produced ionization charge. The main sources of noise contribution of the drift signals are the leakage current between the strips and the strip capacitance. For the leakage current, we used a metallization process that reduces the leakage current by means of a high resistive thin layer between the drift strip electrodes and CZT detector material. This method was applied to all the proto type detectors and was a very effective method to reduce the surface leakage current between the strips. The proto type detector was recently investigated at the European Synchrotron Radiation Facility, Grenoble which provided a fine 50 x 50 mu m(2) collimated X-ray beam covering an energy band up to 600 keV. The Beam positions are resolved very well with a similar to 0.2 mm position resolution (FWHM) at 400 keV in all directions.
引用
收藏
页数:10
相关论文
共 5 条
[1]   Pixelated CdZnTe drift detectors [J].
Kuvvetli, I ;
Budtz-Jorgensen, C .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) :1975-1981
[2]   CZT drift strip detectors for high energy astrophysics [J].
Kuvvetli, I. ;
Budtz-Jorgensen, C. ;
Caroli, E. ;
Auricchio, N. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 624 (02) :486-491
[3]  
Kuvvetli I., 2010, IEEE NUCL SCI S NSS
[4]   Novel electrode geometry to improve performance of CdZnTe detectors [J].
van Pamelen, MAJ ;
Budtz-Jorgensen, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 403 (2-3) :390-398
[5]   CdZnTe drift detector with correction for hole trapping [J].
van Pamelen, MAJ ;
Budtz-Jorgensen, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 411 (01) :197-200