Flow Injection Analysis of Sulfide at a Calmagite-Modified Pencil Graphite Electrode

被引:8
作者
Emir, Gamze [1 ]
Dilgin, Yusuf [1 ]
机构
[1] Canakkale Onsekiz Mart Univ, Dept Chem, Fac Arts & Sci, TR-17100 Canakkale, Turkey
关键词
Calmagite; electrocatalytic oxidation; flow injection analysis; pencil graphite electrode; sulfide; GLASSY-CARBON ELECTRODE; PERFORMANCE LIQUID-CHROMATOGRAPHY; REDUCED GRAPHENE OXIDE; HYDROGEN-SULFIDE; AMPEROMETRIC DETERMINATION; METHYLENE-BLUE; SPECTROPHOTOMETRIC DETERMINATION; ELECTROCHEMICAL DETERMINATION; ELECTROCATALYTIC OXIDATION; VOLTAMMETRIC DETERMINATION;
D O I
10.1080/00032719.2017.1317782
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a new approach is proposed for low cost, sensitive, rapid, and selective detection of sulfide based on its electrocatalytic oxidation at a calmagite-modified pencil graphite electrode. The calmagite-modified pencil graphite electrode was prepared through electropolymerization in which five successive cyclic voltammograms of 0.10 mM monomer on a pencil graphite electrode were recorded in pH 2.0 Britton-Robinson buffer containing 0.10M NaNO3. Cyclic voltammograms of the prepared polycalmagite-modified pencil graphite electrode show that the peak potential of sulfide shifted from +420 mV at an unmodified pencil graphite electrode to +250 mV at the proposed electrode. The results show that a polycalmagite-modified pencil graphite electrode exhibits good electrocatalytic response to the oxidation of sulfide. Flow injection analysis of the sulfide at the polycalmagite-modified pencil graphite electrode was performed under optimized conditions using a home-made electrochemical flow cell constructed specially for the pencil graphite electrode. The anodic peak currents obtained from flow injection amperometric curves at +250 mV in pH 9.0 Britton-Robinson buffer containing 1.0M KCl show that the polycalmagite-modified pencil graphite electrode gave a linear range of 0.10-500.0 mu M and a detection limit of 0.03 mu M. The modified electrode was successfully applied to determine sulfide in real samples, and the method was also verified with recovery studies.
引用
收藏
页码:133 / 150
页数:18
相关论文
共 62 条
  • [51] Electro-biocatalytic treatment of petroleum refinery wastewater using microbial fuel cell (MFC) in continuous mode operation
    Srikanth, Sandipam
    Kumar, Manoj
    Singh, Dheer
    Singh, M. P.
    Das, B. P.
    [J]. BIORESOURCE TECHNOLOGY, 2016, 221 : 70 - 77
  • [52] Amperometric inhibitive biosensor based on horseradish peroxidase-nanoporous gold for sulfide determination
    Sun, Huihui
    Liu, Zhuang
    Wu, Chao
    Xu, Ping
    Wang, Xia
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [53] Electrochemical Detection of Sulfanilamide Using Pencil Graphite Electrode Based on Molecular Imprinting Technology
    Tadi, Kiran Kumar
    Motghare, R. V.
    Ganesh, V.
    [J]. ELECTROANALYSIS, 2014, 26 (11) : 2328 - 2336
  • [54] Electrochemical determination of the anticancer drug taxol at a ds-DNA modified pencil-graphite electrode and its application as a label-free electrochemical biosensor
    Tajik, Somayeh
    Taher, Mohammad Ali
    Beitollahi, Hadi
    Torkzadeh-Mahani, Mosoud
    [J]. TALANTA, 2015, 134 : 60 - 64
  • [55] Treatment of sulfides in tannery baths by nanofiltration
    Taleb-Ahmed, M
    Taha, S
    Chaabane, T
    BenFarès, N
    Brahimi, A
    Maachi, R
    Dorange, G
    [J]. DESALINATION, 2005, 185 (1-3) : 269 - 274
  • [56] Sensitive determination of dissolved sulfide in estuarine water by solid-phase extraction and high-performance liquid chromatography of methylene blue
    Tang, DG
    Santschi, PH
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 883 (1-2) : 305 - 309
  • [57] A reagentless renewable N,N′-diphenyl-p-phenylenediamine loaded sensor for hydrogen sulfide
    Thompson, M
    Lawrence, NS
    Davis, J
    Jiang, L
    Jones, TGJ
    Compton, RG
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 87 (01) : 33 - 40
  • [58] A highly stable and sensitive chemically modified screen-printed electrode for sulfide analysis
    Tsai, DM
    Kumar, AS
    Zen, JM
    [J]. ANALYTICA CHIMICA ACTA, 2006, 556 (01) : 145 - 150
  • [59] Determination of Sulfide by Hematoxylin Multiwalled Carbon Nanotubes Modified Carbon Paste Electrode
    Vu, Dai Long
    Cervenka, Libor
    [J]. ELECTROANALYSIS, 2013, 25 (08) : 1967 - 1973
  • [60] Renewable pencil electrodes for highly sensitive stripping potentiometric measurements of DNA and RNA
    Wang, J
    Kawde, AN
    Sahlin, E
    [J]. ANALYST, 2000, 125 (01) : 5 - 7