Flow Injection Analysis of Sulfide at a Calmagite-Modified Pencil Graphite Electrode

被引:8
作者
Emir, Gamze [1 ]
Dilgin, Yusuf [1 ]
机构
[1] Canakkale Onsekiz Mart Univ, Dept Chem, Fac Arts & Sci, TR-17100 Canakkale, Turkey
关键词
Calmagite; electrocatalytic oxidation; flow injection analysis; pencil graphite electrode; sulfide; GLASSY-CARBON ELECTRODE; PERFORMANCE LIQUID-CHROMATOGRAPHY; REDUCED GRAPHENE OXIDE; HYDROGEN-SULFIDE; AMPEROMETRIC DETERMINATION; METHYLENE-BLUE; SPECTROPHOTOMETRIC DETERMINATION; ELECTROCHEMICAL DETERMINATION; ELECTROCATALYTIC OXIDATION; VOLTAMMETRIC DETERMINATION;
D O I
10.1080/00032719.2017.1317782
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a new approach is proposed for low cost, sensitive, rapid, and selective detection of sulfide based on its electrocatalytic oxidation at a calmagite-modified pencil graphite electrode. The calmagite-modified pencil graphite electrode was prepared through electropolymerization in which five successive cyclic voltammograms of 0.10 mM monomer on a pencil graphite electrode were recorded in pH 2.0 Britton-Robinson buffer containing 0.10M NaNO3. Cyclic voltammograms of the prepared polycalmagite-modified pencil graphite electrode show that the peak potential of sulfide shifted from +420 mV at an unmodified pencil graphite electrode to +250 mV at the proposed electrode. The results show that a polycalmagite-modified pencil graphite electrode exhibits good electrocatalytic response to the oxidation of sulfide. Flow injection analysis of the sulfide at the polycalmagite-modified pencil graphite electrode was performed under optimized conditions using a home-made electrochemical flow cell constructed specially for the pencil graphite electrode. The anodic peak currents obtained from flow injection amperometric curves at +250 mV in pH 9.0 Britton-Robinson buffer containing 1.0M KCl show that the polycalmagite-modified pencil graphite electrode gave a linear range of 0.10-500.0 mu M and a detection limit of 0.03 mu M. The modified electrode was successfully applied to determine sulfide in real samples, and the method was also verified with recovery studies.
引用
收藏
页码:133 / 150
页数:18
相关论文
共 62 条
  • [1] Recent Advances in Nanomaterial-Modified Pencil Graphite Electrodes for Electroanalysis
    Akanda, Md. Rajibul
    Sohail, Manzar
    Aziz, Md. Abdul
    Kawde, Abdel-Nasser
    [J]. ELECTROANALYSIS, 2016, 28 (03) : 408 - 424
  • [2] Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode
    Baciu, Anamaria
    Ardelean, Magdalena
    Pop, Aniela
    Pode, Rodica
    Manea, Florica
    [J]. SENSORS, 2015, 15 (06) : 14526 - 14538
  • [3] Sulfate reducing bacteria in microbial mats: Changing paradigms, new discoveries
    Baumgartner, LK
    Reid, RP
    Dupraz, C
    Decho, AW
    Buckley, DH
    Spear, JR
    Przekop, KM
    Visscher, PT
    [J]. SEDIMENTARY GEOLOGY, 2006, 185 (3-4) : 131 - 145
  • [4] Amperometric Determination of Sulfide by Glassy Carbon Electrode Modified with Hemin Functionalized Reduced Graphene Oxide
    Cao, Xiaodong
    Gao, Jiaona
    Ye, Yingwang
    Wang, Pengfei
    Ding, Shun
    Ye, Yongkang
    Sun, Hanju
    [J]. ELECTROANALYSIS, 2016, 28 (01) : 140 - 144
  • [5] Electrochemical determination of sulfide in fruits using alizarin-reduced graphene oxide nanosheets modified electrode
    Cao, Xiaodong
    Xu, Houchuan
    Ding, Shun
    Ye, Yongkang
    Ge, Xiaoguang
    Yu, Li
    [J]. FOOD CHEMISTRY, 2016, 194 : 1224 - 1229
  • [6] Voltammetric resolution of dopamine in the presence of ascorbic acid and uric acid at poly (calmagite) film coated carbon paste electrode
    Chandra, Umesh
    Swamy, B. E. Kumara
    Gilbert, Ongera
    Sherigara, B. S.
    [J]. ELECTROCHIMICA ACTA, 2010, 55 (24) : 7166 - 7174
  • [7] Highly Stable Polymeric Ionic Liquid Modified Electrode to Immobilize Ferricyanide for Electroanalysis of Sulfide
    Chang, Jen-Lin
    Wei, Guor-Tzo
    Chen, Tsu-Yin
    Zen, Jyh-Myng
    [J]. ELECTROANALYSIS, 2013, 25 (04) : 845 - 849
  • [8] Electrodeposited Ag, Au, and AuAg nanoparticles on graphene oxide-modified screen-printed carbon electrodes for the voltammetric determination of free sulfide in alkaline solutions
    Chen, Yi-Han
    Kirankumar, Rajendranath
    Kao, Chai-Lin
    Chen, Po-Yu
    [J]. ELECTROCHIMICA ACTA, 2016, 205 : 124 - 131
  • [9] Colorimetric detection of sulfide based on target-induced shielding against the peroxidase-like activity of gold nanoparticles
    Deng, Hao-Hua
    Weng, Shao-Huang
    Huang, Shuang-Lu
    Zhang, Ling-Na
    Liu, Ai-Lin
    Lin, Xin-Hua
    Chen, Wei
    [J]. ANALYTICA CHIMICA ACTA, 2014, 852 : 218 - 222
  • [10] Differential pulse voltammetric determination of acyclovir in pharmaceutical preparations using a pencil graphite electrode
    Dilgin, Didem Giray
    Karakaya, Serkan
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 63 : 570 - 576