Thread shape affects the stress distribution of torque force on miniscrews: a finite element analysis

被引:6
作者
Ye, Yu-shan [1 ]
Yi, Wei-min [2 ]
Zhuang, Pei-lin [1 ]
Liu, Mo [1 ]
Yu, Yan-song [1 ]
Lu, Ying-juan [1 ]
Yao, Qing-he [3 ]
Wang, Wei [4 ]
Chang, Shao-hai [1 ]
机构
[1] Sun Yat Sen Univ, Sun Yat Sen Mem Hosp, Dept Stomatol, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ, Sun Yat Sen Mem Hosp, Dept Integrat Med, Guangzhou, Peoples R China
[3] Sun Yat Sen Univ, Sch Engn, Guangzhou, Peoples R China
[4] Urumqi DW Innovat Info Tech Co Ltd, Urumqi, Peoples R China
基金
美国国家科学基金会;
关键词
Orthodontic anchorage; miniscrew; torque force; finite element analysis; thread shape; PRIMARY STABILITY; IMPLANT DESIGN; MINI-IMPLANT; BONE; DIAMETERS; BEHAVIOR;
D O I
10.1080/10255842.2020.1784884
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This study aimed to investigate the effect of miniscrews thread shape on the stress distribution receiving a torque load. Seven thread shapes (S,V1,V2,B1,B2,R1,R2) models were constructed and a 6 Nmm-torque load was applied. The order of maximum equivalent stress (EQV) value was V1 > V2 > B1 > R1 > R2 > B2 > S. The order of maximum displacement of miniscrew (Max DM) value was S > B2 > R1 = V1 > B1 > V2 > R2. Model R2 may be the most appropriate thread shape affording a torque force.
引用
收藏
页码:1034 / 1040
页数:7
相关论文
共 41 条
[1]   The effect of thread pattern upon implant osseointegration [J].
Abuhussein, Heba ;
Pagni, Giorgio ;
Rebaudi, Alberto ;
Wang, Hom-Lay .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (02) :129-136
[2]  
[Anonymous], 2001, KOREAN J ORAL SURG
[3]  
[Anonymous], 2012, CHIN J ORTHOD
[4]   Mechanical behavior of an osteotomized mandible with distraction orthodontic devices [J].
Boccaccio, A. ;
Lamberti, L. ;
Pappalettere, C. ;
Carano, A. ;
Cozzani, M. .
JOURNAL OF BIOMECHANICS, 2006, 39 (15) :2907-2918
[5]   Pitch and Longitudinal Fluting Effects on the Primary Stability of Miniscrew Implants [J].
Brinley, Christine L. ;
Behrents, Rolf ;
Kim, Ki Beom ;
Condoor, Sridhar ;
Kyung, Hee-Moon ;
Buschang, Peter H. .
ANGLE ORTHODONTIST, 2009, 79 (06) :1156-1161
[6]   Miniscrew implant applications in contemporary orthodontics [J].
Chang, Hong-Po ;
Tseng, Yu-Chuan .
KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2014, 30 (03) :111-115
[7]   Effects of thread depth, taper shape, and taper length on the mechanical properties of mini-implants [J].
Chang, Jenny Zwei-Chieng ;
Chen, Yi-Jane ;
Tung, Yuan-Yi ;
Chiang, Yu-Ying ;
Lai, Eddie Hsiang-Hua ;
Chen, Weng-Pin ;
Lin, Chun-Pin .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 141 (03) :279-288
[8]  
Dalstra M., 2004, ORTHOD, V1, P53
[9]  
Desai Shrikar R, 2013, J Indian Soc Periodontol, V17, P637, DOI 10.4103/0972-124X.119283
[10]   Factors affecting stresses in cortical bone around miniscrew implants A three-dimensional finite element study [J].
Duaibis, Ramzi ;
Kusnoto, Budi ;
Natarajan, Raghu ;
Zhao, Linping ;
Evans, Carla .
ANGLE ORTHODONTIST, 2012, 82 (05) :875-880