Locking plate fixation of proximal humerus fractures in patients older than 60 years continues to be associated with a high complication rate

被引:80
|
作者
Barlow, Jonathan D. [1 ]
Logli, Anthony L. [1 ]
Steinmann, Scott P. [1 ]
Sems, Stephen A. [1 ]
Cross, William W. [1 ]
Yuan, Brandon J. [1 ]
Torchia, Michael E. [1 ]
Sanchez-Sotelo, Joaquin [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, Rochester, MN USA
关键词
Proximal humerus fracture; open reduction internal fixation (ORIF); locking plates; Neer classification; elderly fracture; pathologic fracture; INTERNAL-FIXATION; SHOULDER ARTHROPLASTY; SURGICAL-TREATMENT; ELDERLY-PATIENTS; TRENDS;
D O I
10.1016/j.jse.2019.11.026
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Locking plate technology has increased the frequency of open reduction and internal fixation (ORIF) of proximal humerus fractures (PHF). A number of technical pearls have been recommended to lower the complication rate of ORIF. These pearls are particularly relevant for patients aged >60 years, when nonoperative treatment and arthroplasty are alternatives commonly considered. There have been few large, single-center studies on the modern application of this technology. Methods: Between 2005 and 2015, a total of 173 PHFs in patients aged >60 years were treated at our institution with ORIF using locking plates. Failure was defined as reoperation or radiographic evidence of failure. Average follow-up was 6.1 years. Results: There was an overall complication rate of 44%. The overall failure rate was 34% and correlated with fracture type: 26% failure rate in 2-part fractures (16 failures), 39% in 3-part fractures (23 failures), and 45% in 4-part fractures (11 failures). There was no difference between the failure rate with and without fibular allograft (33% vs. 34%). Most patients with radiographic or clinical failure did not undergo reoperation. The overall reoperation rate was 11% (14 patients). Seven percent of 2-part fractures (4 shoulders), 14% of 3-part fractures (8 shoulders), and 18% of 4-part fractures (2 shoulders) required reoperation. Conclusions: ORIF of PHFs with locking plates in patients aged >60 years resulted in a 44% complication and 34% failure rate. There was a trend toward higher complication and failure rates in older patients and more complex fractures. Refinement in fixation techniques and indications are necessary to optimize the surgical management of PHFs. (C) 2020 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:1689 / 1694
页数:6
相关论文
共 50 条
  • [41] Internal fixation of proximal humeral fractures with locking proximal humeral plate (LPHP) in elderly patients with osteoporosis
    Siwach R.
    Singh R.
    Rohilla R.K.
    Kadian V.S.
    Sangwan S.S.
    Dhanda M.
    Journal of Orthopaedics and Traumatology, 2008, 9 (3) : 149 - 153
  • [42] Quality of life, functional and radiological outcomes of treatment of three-part and four-part proximal humerus fractures with locking plates and comparison in young versus older than 70 years: a retrospective cohort study
    Godoy, Ignacio Descalzo
    Alcalde, Paula Velasco
    Galeano, Alberto Del Olmo
    Hortelano, Julian Del Rio
    Velez, David Martinez
    Gonzalez, Julian Fernandez
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (01) : 415 - 423
  • [43] CORR® Synthesis: What Is the Role of Reverse Shoulder Arthroplasty for the Treatment of Proximal Humerus Fractures in Patients Older Than 65 Years?
    Boin, Michael A.
    Virk, Mandeep S.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2021, 479 (11) : 2421 - 2429
  • [44] Reverse shoulder arthroplasty for the treatment of three and four part fractures of the proximal humerus in patients older than 75 years old
    Kaisidis, Aristotelis
    Pantos, Pallayiotis G.
    Heger, Horst
    Bochlos, Dimitrios
    Selimas, Sotirios
    Oikonomoulas, Vasileios
    ACTA ORTHOPAEDICA BELGICA, 2014, 80 (01): : 99 - 105
  • [45] Reverse Total Shoulder Arthroplasty Demonstrates Better Outcomes Than Angular Stable Plate in the Treatment of Three-part and Four-part Proximal Humerus Fractures in Patients Older Than 70 Years
    Lanzetti, Riccardo Maria
    Gaj, Edoardo
    Berlinberg, Elyse J.
    Patel, Harsh H.
    Spoliti, Marco
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2023, 481 (04) : 735 - 747
  • [46] Displaced femoral neck fractures in patients 60 years of age or younger: results of internal fixation with the dynamic locking blade plate
    Kalsbeek, J. H.
    van Walsum, A. D. P.
    Vroemen, J. P. A. M.
    Janzing, H. M. J.
    Winkelhorst, J. T.
    Bertelink, B. P.
    Roerdink, W. H.
    BONE & JOINT JOURNAL, 2018, 100B (04) : 443 - 449
  • [47] Results of an innovative method of intramedullary fixation for displaced 4-part fractures of the proximal humerus in patients younger than 70 years
    Desai, Sanjay
    Jain, Rohit
    Singh, Vishwajeet
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (02) : 331 - 339
  • [48] Comparison of "Bilboquet" device and locking plate for surgical treatment of proximal humerus complex fractures at two years follow-up
    Bismuth, Yaniv
    Cambon-Binder, Adeline
    Sautet, Alain
    Doursounian, Levon
    Gregory, Thomas
    Bastard, Claire
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (07) : 1811 - 1816
  • [49] Comparison of “Bilboquet” device and locking plate for surgical treatment of proximal humerus complex fractures at two years follow-up
    Yaniv Bismuth
    Adeline Cambon-Binder
    Alain Sautet
    Levon Doursounian
    Thomas Gregory
    Claire Bastard
    International Orthopaedics, 2021, 45 : 1811 - 1816
  • [50] PROMIS Physical Function Computer Adaptive Test Compared With Other Upper Extremity Outcome Measures in the Evaluation of Proximal Humerus Fractures in Patients Older Than 60 Years
    Morgan, Jordan H.
    Kallen, Michael A.
    Okike, Kanu
    Lee, Olivia C.
    Vrahas, Mark S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (06) : 257 - 263