Locking plate fixation of proximal humerus fractures in patients older than 60 years continues to be associated with a high complication rate

被引:88
作者
Barlow, Jonathan D. [1 ]
Logli, Anthony L. [1 ]
Steinmann, Scott P. [1 ]
Sems, Stephen A. [1 ]
Cross, William W. [1 ]
Yuan, Brandon J. [1 ]
Torchia, Michael E. [1 ]
Sanchez-Sotelo, Joaquin [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, Rochester, MN USA
关键词
Proximal humerus fracture; open reduction internal fixation (ORIF); locking plates; Neer classification; elderly fracture; pathologic fracture; INTERNAL-FIXATION; SHOULDER ARTHROPLASTY; SURGICAL-TREATMENT; ELDERLY-PATIENTS; TRENDS;
D O I
10.1016/j.jse.2019.11.026
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Locking plate technology has increased the frequency of open reduction and internal fixation (ORIF) of proximal humerus fractures (PHF). A number of technical pearls have been recommended to lower the complication rate of ORIF. These pearls are particularly relevant for patients aged >60 years, when nonoperative treatment and arthroplasty are alternatives commonly considered. There have been few large, single-center studies on the modern application of this technology. Methods: Between 2005 and 2015, a total of 173 PHFs in patients aged >60 years were treated at our institution with ORIF using locking plates. Failure was defined as reoperation or radiographic evidence of failure. Average follow-up was 6.1 years. Results: There was an overall complication rate of 44%. The overall failure rate was 34% and correlated with fracture type: 26% failure rate in 2-part fractures (16 failures), 39% in 3-part fractures (23 failures), and 45% in 4-part fractures (11 failures). There was no difference between the failure rate with and without fibular allograft (33% vs. 34%). Most patients with radiographic or clinical failure did not undergo reoperation. The overall reoperation rate was 11% (14 patients). Seven percent of 2-part fractures (4 shoulders), 14% of 3-part fractures (8 shoulders), and 18% of 4-part fractures (2 shoulders) required reoperation. Conclusions: ORIF of PHFs with locking plates in patients aged >60 years resulted in a 44% complication and 34% failure rate. There was a trend toward higher complication and failure rates in older patients and more complex fractures. Refinement in fixation techniques and indications are necessary to optimize the surgical management of PHFs. (C) 2020 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:1689 / 1694
页数:6
相关论文
共 27 条
[1]   Complications encountered in proximal humerus fractures treated with locking plate fixation [J].
Aksu, Neslihan ;
Gogus, Abdullah ;
Kara, Ayhan Nedim ;
Isiklar, Zekeriya Ugur .
ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2010, 44 (02) :89-96
[2]   Proximal Humerus Fractures in the Elderly Can Be Reliably Fixed With a "Hybrid" Locked-plating Technique [J].
Barlow, Jonathan D. ;
Sanchez-Sotelo, Joaquin ;
Torchia, Michael .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (12) :3281-3291
[3]   Trends and Variation in Incidence, Surgical Treatment, and Repeat Surgery of Proximal Humeral Fractures in the Elderly [J].
Bell, John-Erik ;
Leung, Brian C. ;
Spratt, Kevin F. ;
Koval, Ken J. ;
Weinstein, James D. ;
Goodman, David C. ;
Tosteson, Anna N. A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (02) :121-131
[4]   Internal fixation of proximal humeral fractures with a locking compression plate -: A retrospective evaluation of 72 patients followed for a minimum of 1 year [J].
Björkenheim, JM ;
Pajarinen, J ;
Savolainen, V .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (06) :741-745
[5]   Nondisplaced proximal humeral fractures: high incidence among outpatient-treated osteoporotic fractures and severe impact on upper extremity function and patient subjective health perception [J].
Calvo, Emilio ;
Morcillo, Diana ;
Foruria, Antonio M. ;
Redondo-Santamar, Enrique ;
Osorio-Picorne, Fernando ;
Caeiro, Jose R. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (05) :795-801
[6]   A new locking plate for unstable fractures of the proximal humerus [J].
Fankhauser, F ;
Boldin, C ;
Schippinger, G ;
Haunschmid, C ;
Szyszkowitz, R .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (430) :176-181
[7]   Surgical Treatment With an Angular Stable Plate for Complex Displaced Proximal Humeral Fractures in Elderly Patients: A Randomized Controlled Trial [J].
Fjalestad, Tore ;
Hole, Margrethe O. ;
Hovden, Inger Anette Hynas ;
Blucher, Judith .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (02) :98-106
[8]   The pattern of the fracture and displacement of the fragments predict the outcome in proximal humeral fractures [J].
Foruria, A. M. ;
de Gracia, M. M. ;
Larson, D. R. ;
Munuera, L. ;
Sanchez-Sotelo, J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (03) :378-386
[9]  
Gaheer Rajinder Singh, 2010, Orthopedics, V33, P671, DOI 10.3928/01477447-20100722-11
[10]   The importance of medial support in locked plating of proximal humerus fractures [J].
Gardner, Michael J. ;
Weil, Yoram ;
Barker, Joseph U. ;
Kelly, Bryan T. ;
Helfet, David L. ;
Lorich, Dean G. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (03) :185-191