GEANT4 Monte Carlo simulations for virtual clinical trials in breast X-ray imaging: Proof of concept

被引:32
作者
di Franco, F. [1 ,2 ]
Sarno, A. [1 ,2 ]
Mettivier, G. [1 ,2 ]
Hernandez, A. M. [3 ]
Bliznakova, K. [4 ]
Boone, J. M. [3 ]
Russo, P. [1 ,2 ]
机构
[1] Univ Napoli Federico II, Dipartimento Fis Ettore Pancini, Naples, Italy
[2] INFN, Sez Napoli, Naples, Italy
[3] Univ Calif Davis, Med Ctr, Dept Radiol, Sacramento, CA 95817 USA
[4] Med Univ Varna, Dept Med Equipment Elect & Informat Technol Healt, Varna, Bulgaria
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2020年 / 74卷
关键词
Virtual clinical trials; X-ray breast imaging; Monte Carlo; Patient-derived breast phantoms; GLANDULAR DOSE COEFFICIENTS; ROTATIONAL RADIOTHERAPY; COMPUTED-TOMOGRAPHY; TOMOSYNTHESIS; COMPRESSION; MAMMOGRAPHY; MODEL; CT;
D O I
10.1016/j.ejmp.2020.05.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Virtual clinical trials (VCT) are in-silico reproductions of medical examinations, which adopt digital models of patients and simulated devices. They are intended to produce clinically equivalent outcome data avoiding long execution times, ethical issues related to radiation induced risks and huge costs related to real clinical trials with a patient population. In this work, we present a platform for VCT in 2D and 3D X-ray breast imaging. The VCT platform uses Monte Carlo simulations based on the Geant4 toolkit and patient breast models derived from a cohort of high resolution dedicated breast CT (BCT) volume data sets. Projection images of the breast and three-dimensional glandular dose maps are generated for a given breast model, by simulating both 2D full-field digital mammography (DM) and 3D BCT examinations. Uncompressed voxelized breast models were derived from segmented patient images. Compressed versions of the digital breast phantoms for DM were generated using a previously published digital compression algorithm. The Monte Carlo simulation framework has the capability of generating and tracking similar to 10(5) photons/s using a server equipped with 16-cores and 3.0 GHz clock speed. The VCT platform will provide a framework for scanner design optimization, comparison between different scanner designs and between different modalities or protocols on computational breast models, without the need for scanning actual patients as in conventional clinical trials.
引用
收藏
页码:133 / 142
页数:10
相关论文
共 48 条
[1]  
ACR, 2016, DIG MAMM QUAL CONTR
[2]   Conspicuity of suspicious breast lesions on contrast enhanced breast CT compared to digital breast tomosynthesis and mammography [J].
Aminololama-Shakeri, Shadi ;
Abbey, Craig K. ;
Lopez, Javier E. ;
Hernandez, Andrew M. ;
Gazi, Peymon ;
Boone, John M. ;
Lindfors, Karen K. .
BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1097)
[3]  
[Anonymous], P SPIE
[4]  
[Anonymous], PHYS MED
[5]  
[Anonymous], 2006, EUR GUID QUAL ASS BR
[6]  
[Anonymous], INT SOC OPTICS PHOTO
[7]   Accelerating Monte Carlo simulations of photon transport in a voxelized geometry using a massively parallel graphics processing unit [J].
Badal, Andreu ;
Badano, Aldo .
MEDICAL PHYSICS, 2009, 36 (11) :4878-4880
[8]  
Badano A, 2018, JAMA NETW OPEN, V1, DOI [10.1001/jamanetworkopen.2018.5474, 10.1007/s42001-018-0015-z]
[9]   Virtual clinical trial of lesion detection in digital mammography and digital breast tomosynthesis [J].
Bakic, Predrag R. ;
Barufaldi, Bruno ;
Higginbotham, David ;
Weinstein, Susan P. ;
Avanaki, Ali N. ;
Espig, Kathryn S. ;
Xthona, Albert ;
Kimpe, Tom R. L. ;
Maidment, Andrew D. A. .
MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
[10]   Evaluation of a breast software model for 2D and 3D X-ray imaging studies of the breast [J].
Baneva, Yanka ;
Bliznakova, Kristina ;
Cockmartin, Lesley ;
Marinov, Stoyko ;
Buliev, Ivan ;
Mettivier, Giovanni ;
Bosmans, Hilde ;
Russo, Paolo ;
Marshall, Nicholas ;
Bliznakov, Zhivko .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 41 :78-86