Improved Direct Power Control of a Wind Turbine Driven Doubly Fed Induction Generator During Transient Grid Voltage Unbalance

被引:95
作者
Nian, Heng [1 ]
Song, Yipeng [1 ]
Zhou, Peng [1 ]
He, Yikang [1 ]
机构
[1] Zhejiang Univ, Dept Elect Engn, Hangzhou 310027, Zhejiang, Peoples R China
关键词
Direct power control (DPC); doubly fed induction generator (DFIG); grid voltage unbalance; resonant controller; wind turbine; ENHANCED CONTROL; DFIG; OPERATION; MACHINE; ROTOR;
D O I
10.1109/TEC.2011.2158436
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes an improved direct power control (DPC) strategy for a doubly fed induction generator (DFIG)-based wind power generation system under unbalanced grid voltage dips. The fundamental and double grid frequency power pulsations, which are produced by the transient unbalanced grid faults, are mathematically analyzed and accurately regulated. Five selectable control targets, with proper power references given, are designed for different applications during network unbalance. In order to provide enhanced control performance, two resonant controllers, which are tuned to have large gain at the power pulsation frequencies, are applied together with the proportional-integral controller to achieve full control of the DFIG output power. The effectiveness of the proposed DPC strategy is verified by the experimental results of a 5-kW DFIG system under different unbalanced voltage dips, which are generated by a specially designed voltage dip generator.
引用
收藏
页码:976 / 986
页数:11
相关论文
共 30 条
[1]   Two-level VSC-based predictive direct power control of the doubly fed induction machine with reduced power ripple at low constant switching frequency [J].
Abad, Gonzalo ;
Rodriguez, Miguel Angel ;
Poza, Javier .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (02) :570-580
[2]   Direct Power Control of Doubly-Fed-Induction-Generator-Based Wind Turbines Under Unbalanced Grid Voltage [J].
Abad, Gonzalo ;
Angel Rodriguez, Miguel ;
Iwanski, Grzegorz ;
Poza, Javier .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (02) :442-452
[3]  
BOLLEN MHJ, 1999, UNDERSTANDING POWER, P191
[4]   Control of a doubly fed induction wind generator under unbalanced grid voltage conditions [J].
Brekken, Ted K. A. ;
Mohan, Ned .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) :129-135
[5]   Direct power control of grid-connected wound rotor induction machine without rotor position sensors [J].
Datta, R ;
Ranganathan, VT .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2001, 16 (03) :390-399
[6]  
ELOYGARCIA J, 2007, POWER ELECT, V1, P395
[7]  
Ghosh A., 2002, POWER QUALITY ENHANC, P87
[8]   Modeling and enhanced control of DFIG under unbalanced grid voltage conditions [J].
Hu, Jiabing ;
He, Yikang .
ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (02) :273-281
[9]   International comparison of requirements for connection of wind turbines to power systems [J].
Jauch, C ;
Matevosyan, J ;
Ackermann, T ;
Bolik, S .
WIND ENERGY, 2005, 8 (03) :295-306
[10]   Wind turbines based on doubly fed induction generator under asymmetrical voltage dips [J].
Lopez, Jesus ;
Gubia, Eugenio ;
Sanchis, Pablo ;
Roboam, Xavier ;
Marroyo, Luis .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (01) :321-330