Strut apposition after coronary stent implantation visualised with optical coherence tomography

被引:2
|
作者
Radu, Maria [1 ]
Jorgensen, Erik [1 ]
Kelbaek, Henning [1 ]
Helqvist, Steffen [1 ]
Skovgaard, Lene [2 ]
Saunamaki, Karl [1 ]
机构
[1] Univ Copenhagen, Ctr Heart, Dept Cardiol, Rigshosp, DK-2100 Copenhagen, Denmark
[2] Univ Copenhagen, Dept Biostat, DK-2100 Copenhagen, Denmark
关键词
OCT; strut apposition; stent implantation; invasive imaging; INTRAVASCULAR ULTRASOUND ANALYSIS; INTRACORONARY ULTRASOUND; NEOINTIMAL COVERAGE; ELUTING STENTS; THROMBOSIS;
D O I
10.4244/EIJV6I1A13
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To describe different patterns of stent strut apposition, as visualised with optical coherence tomography. Methods and results: Strut thicknesses were reconstructed according to the manufacturers' specifications. The stent area (SA) was measured by connecting the reconstructed abluminal surfaces of struts with a trace line, and the vessel wall area (VWA) was estimated from the abluminal strut surfaces, as well as from the lumen border, in cases of struts that were separated from the vessel wall by flush. Strut apposition was evaluated by comparing the SA- and VWA traces. We observed four patterns of strut apposition. Based on these, stent struts could be classified as: (I) apposed struts, (II) struts overlying the ostium of a side branch, (Ill) malapposed struts that were clearly separated from the vessel wall by flush, and (IV) pseudoapposed struts that were not separated from the vessel wall by visual estimate, but were malapposed in the sense that SA<VWA. Pseudoapposed struts were found in frames with "flower-shaped" lumen contours, and were often surrounded by structures of a lower signal intensity than the rest of the vessel wall. Conclusions: For a detailed analysis of strut apposition with OCT, we reconstructed strut thicknesses and estimated stent- and vessel wall areas. With this method, we found four types of strut apposition, where pseudoapposed struts constitute a type of struts not previously described. The clinical importance of pseudoapposed struts remains to be settled.
引用
收藏
页码:86 / 93
页数:8
相关论文
共 50 条
  • [21] Optical coherence tomography to evaluate coronary stent implantation and complications
    Hayat, Umair
    Thondapu, Vikas
    Ul Haq, Muhammad Asrar
    Foin, Nicolas
    Jang, Ik-Kyung
    Barlis, Peter
    CORONARY ARTERY DISEASE, 2015, 26 : E55 - E68
  • [22] Optical Coherence Tomography Appearances in Healed Coronary Artery Aneurysms After Stent Implantation
    Viswanathan, Girish N.
    Chowdhary, Saqib
    Anderson, Richard A.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (03) : 336 - 337
  • [23] Temporal changes of stent apposition immediately after stent deployment using optical coherence tomography
    Yoon, Hyuck Jun
    Hur, Seung-Ho
    Cho, Yun-Kyeong
    Nam, Chang-Wook
    Choi, Sang-Woong
    Oh, Jun-Hyok
    Lee, Cheol Hyun
    Kim, In-Cheol
    Kim, Hyungseop
    Park, Hyoung-Seob
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B202 - B203
  • [24] Stent strut detection in intravascular optical coherence tomography
    Carreira, Maria J.
    Gonzalez, Y. M.
    Penedo, M. G.
    Trillo, R.
    PROCEEDINGS OF THE 2013 8TH IBERIAN CONFERENCE ON INFORMATION SYSTEMS AND TECHNOLOGIES (CISTI 2013), 2013,
  • [25] Optical coherence tomography or intravascular ultrasound to optimize coronary stent implantation
    Alfonso, Fernando
    Prati, Francesco
    EUROPEAN HEART JOURNAL, 2017, 38 (42) : 3148 - 3151
  • [26] Optical Coherence Tomography Imaging: Novel Insights into the Vascular Response After Coronary Stent Implantation
    Milosz Jaguszewski
    Ulf Landmesser
    Current Cardiovascular Imaging Reports, 2012, 5 (4) : 231 - 238
  • [27] Optical Coherence Tomography Imaging: Novel Insights into the Vascular Response After Coronary Stent Implantation
    Jaguszewski, Milosz
    Landmesser, Ulf
    CURRENT CARDIOVASCULAR IMAGING REPORTS, 2012, 5 (04) : 231 - 238
  • [28] Incomplete Stent Apposition after Coronary Stent Implantation: Myth or Reality?
    Rathore, Sudhir
    Terashima, Mitsuyasu
    Habara, M.
    Kinoshita, Yoshihisa
    Nasu, Kenya
    Katoh, Osamu
    Suzuki, Takahiko
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2009, 22 (04) : 341 - 349
  • [29] Relationship between stent apposition pattern and neointimal coverage after sirolimus-eluting stent implantation: Analysis by optical coherence tomography imaging
    Terashima, M
    Ito, T
    Katoh, O
    Malsubara, T
    Tsuchikane, E
    Ehara, M
    Kinoshita, Y
    Suzuki, T
    Takeda, Y
    Nasu, K
    Surmely, JF
    Tanaka, N
    Murata, A
    Suzuki, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 13B - 13B
  • [30] Influence of Strut Width on Neointimal Coverage After Sirolimus-Eluting Stent Implantation Assessed by Optical Coherence Tomography
    Nakatani, Shimpei
    CIRCULATION, 2009, 120 (18) : S947 - S947