Strut apposition after coronary stent implantation visualised with optical coherence tomography

被引:2
作者
Radu, Maria [1 ]
Jorgensen, Erik [1 ]
Kelbaek, Henning [1 ]
Helqvist, Steffen [1 ]
Skovgaard, Lene [2 ]
Saunamaki, Karl [1 ]
机构
[1] Univ Copenhagen, Ctr Heart, Dept Cardiol, Rigshosp, DK-2100 Copenhagen, Denmark
[2] Univ Copenhagen, Dept Biostat, DK-2100 Copenhagen, Denmark
关键词
OCT; strut apposition; stent implantation; invasive imaging; INTRAVASCULAR ULTRASOUND ANALYSIS; INTRACORONARY ULTRASOUND; NEOINTIMAL COVERAGE; ELUTING STENTS; THROMBOSIS;
D O I
10.4244/EIJV6I1A13
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To describe different patterns of stent strut apposition, as visualised with optical coherence tomography. Methods and results: Strut thicknesses were reconstructed according to the manufacturers' specifications. The stent area (SA) was measured by connecting the reconstructed abluminal surfaces of struts with a trace line, and the vessel wall area (VWA) was estimated from the abluminal strut surfaces, as well as from the lumen border, in cases of struts that were separated from the vessel wall by flush. Strut apposition was evaluated by comparing the SA- and VWA traces. We observed four patterns of strut apposition. Based on these, stent struts could be classified as: (I) apposed struts, (II) struts overlying the ostium of a side branch, (Ill) malapposed struts that were clearly separated from the vessel wall by flush, and (IV) pseudoapposed struts that were not separated from the vessel wall by visual estimate, but were malapposed in the sense that SA<VWA. Pseudoapposed struts were found in frames with "flower-shaped" lumen contours, and were often surrounded by structures of a lower signal intensity than the rest of the vessel wall. Conclusions: For a detailed analysis of strut apposition with OCT, we reconstructed strut thicknesses and estimated stent- and vessel wall areas. With this method, we found four types of strut apposition, where pseudoapposed struts constitute a type of struts not previously described. The clinical importance of pseudoapposed struts remains to be settled.
引用
收藏
页码:86 / 93
页数:8
相关论文
共 21 条
  • [1] Late incomplete stent apposition after sirolimus-eluting stent implantation - A serial intravascular ultrasound analysis
    Ako, J
    Morino, Y
    Honda, Y
    Hassan, A
    Sonoda, S
    Yock, PG
    Leon, MB
    Moses, JW
    Bonneau, HN
    Fitzgerald, PJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (06) : 1002 - 1005
  • [2] Evaluation of intracoronary stenting by intravascular optical coherence tomography
    Bouma, BE
    Tearney, GJ
    Yabushita, H
    Shishkov, M
    Kauffman, CR
    Gauthier, DD
    MacNeill, BD
    Houser, SL
    Aretz, HT
    Halpern, EF
    Jang, IK
    [J]. HEART, 2003, 89 (03) : 317 - 320
  • [3] Augmentation of wall shear stress inhibits neointimal hyperplasia after stent implantation - Inhibition through reduction of inflammation?
    Carlier, SG
    van Damme, LCA
    Blommerde, CP
    Wentzel, JJ
    van Langehove, G
    Verheye, S
    Kockx, MM
    Knaapen, MWM
    Cheng, C
    Gijsen, F
    Duncker, DJ
    Stergiopulos, N
    Slager, CJ
    Serruys, PW
    Krams, R
    [J]. CIRCULATION, 2003, 107 (21) : 2741 - 2746
  • [4] Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation
    Cook, Stephane
    Wenaweser, Peter
    Togni, Mario
    Billinger, Michael
    Morger, Cyrill
    Seiler, Christian
    Vogel, Rolf
    Hess, Otto
    Meier, Bernhard
    Windecker, Stephan
    [J]. CIRCULATION, 2007, 115 (18) : 2426 - 2434
  • [5] Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization
    Finn, Aloke V.
    Joner, Michael
    Nakazawa, Gaku
    Kolodgie, Frank
    Newell, John
    John, Mike C.
    Gold, Herman K.
    Virmani, Renu
    [J]. CIRCULATION, 2007, 115 (18) : 2435 - 2441
  • [6] BENEFIT OF INTRACORONARY ULTRASOUND IN THE DEPLOYMENT OF PALMAZ-SCHATZ STENTS
    GOLDBERG, SL
    COLOMBO, A
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    TOBIS, JM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) : 996 - 1003
  • [7] Reproducibility of quantitative optical coherence tomography for stent analysis
    Gonzalo, Nieves
    Garcia-Garcia, Hector M.
    Serruys, Patrick W.
    Commissaris, Koen H.
    Bezerra, Hiram
    Gobbens, Pierre
    Costa, Marco
    Regar, Evelyn
    [J]. EUROINTERVENTION, 2009, 5 (02) : 224 - 232
  • [8] Optical coherence tomography patterns of stent restenosis
    Gonzalo, Nieves
    Serruys, Patrick W.
    Okamura, Takaynki
    van Beusekom, Heleen M.
    Garcia-Garcia, Hector M.
    van Soest, Gijs
    van der Giessen, Wim
    Regar, Evelyn
    [J]. AMERICAN HEART JOURNAL, 2009, 158 (02) : 284 - 293
  • [9] GUAGLIUMI G, 2008, CIRCULATION, V118, P2315
  • [10] Impact of late incomplete stent apposition after sirolimus-eluting stent implantation on 4-year clinical events: intravascular ultrasound analysis from the multicentre, randomised, RAVEL, E-SIRIUS and SIRIUS trials
    Hoffmann, R.
    Morice, M-C
    Moses, J. W.
    Fitzgerald, P. J.
    Mauri, L.
    Breithardt, G.
    Schofer, J.
    Serruys, P. W.
    Stoll, H-P
    Leon, M. B.
    [J]. HEART, 2008, 94 (03) : 322 - 328