The Effect of Occupants' Behaviour on the Building Performance Gap: UK Residential Case Studies

被引:7
作者
Bahadori-Jahromi, Ali [1 ]
Salem, Radwa [1 ]
Mylona, Anastasia [2 ]
Hasan, Agha Usama [1 ]
Zhang, Hexin [3 ]
机构
[1] Univ West London, Sch Comp & Engn, Dept Civil Engn & Built Environm, London W5 5RF, England
[2] Chartered Inst Bldg Serv Engn CIBSE, Res Dept, London SW12 9BS, England
[3] Edinburgh Napier Univ, Sch Engn & Built Environm, 10 Clinton Rd, Edinburgh EH10 5DT, Midlothian, Scotland
关键词
thermal analysis simulation; performance gap; residential homes; occupant behaviour; HOUSEHOLD ENERGY-CONSUMPTION; SENSITIVITY-ANALYSIS; POTENTIAL IMPACT; CLIMATE; COMFORT; TOOL;
D O I
10.3390/su14031362
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Studies have shown that the assumptions used to create dynamic thermal models of buildings do not reflect their actual energy use. Bridging the energy performance gap is vital in ensuring that a designed or retrofitted building meets the energy performance targets. Using thermal analysis simulation software TAS, this paper presents a simulation model of seven different UK single family houses. The results from the various models are validated by comparing the actual energy demand against the simulated consumption. The simulation results show that the heating set point has the greatest impact on the simulated energy demand. The results also demonstrate that the energy demand of the dwellings can be reduced by applying window opening schemes and by controlling the heating setpoint temperature and schedule. Plug load consumption is also considered by using plug load data of real UK households, as obtained from a longitudinal study, and calibrating the model based on average plug load contributions for the households. The results showed that, by increasing the heating set point and window opening schedules by 10% from self-reported data, and by considering an additional 12% for plug loads, the energy performance gap is reduced to less than >15% for all examined houses.
引用
收藏
页数:18
相关论文
共 55 条
[1]   Impact of standard construction specification on thermal comfort in UK dwellings [J].
Amoako-Attah, Joseph ;
B-Jahromi, Ali .
ADVANCES IN ENVIRONMENTAL RESEARCH-AN INTERNATIONAL JOURNAL, 2014, 3 (03) :253-281
[2]  
[Anonymous], CIBSE WEATH DAT SETS
[3]  
Asdrubali F., 2014, CASE STUD CONSTR MAT, V1, P53, DOI DOI 10.1016/J.CSCM.2014.04.004
[4]  
Aydin E., REBOUND EFFECT RESID
[5]   A study and a directory of energy consumption data sets of buildings [J].
Babaei, Toktam ;
Abdi, Hamid ;
Lim, Chee Peng ;
Nahavandi, Saeid .
ENERGY AND BUILDINGS, 2015, 94 :91-99
[6]   A review of occupant behaviour in residential buildings [J].
Balvedi, Bruna Faitao ;
Ghisi, Enedir ;
Lamberts, Roberto .
ENERGY AND BUILDINGS, 2018, 174 :495-505
[7]   Assessing building performance in use 3: energy performance of the Probe buildings [J].
Bordass, B ;
Cohen, R ;
Standeven, M ;
Leaman, A .
BUILDING RESEARCH AND INFORMATION, 2001, 29 (02) :114-128
[8]  
Bordass B., 2004, P 3 INT C IMPR EN EF
[9]   Predicted versus observed heat consumption of a low energy multifamily complex in Switzerland based on long-term experimental data [J].
Branco, G ;
Lachal, B ;
Gallinelli, P ;
Weber, W .
ENERGY AND BUILDINGS, 2004, 36 (06) :543-555
[10]   VENTILATION - BEHAVIORAL-APPROACH [J].
BRUNDRETT, GW .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1977, 1 (04) :289-298