Complement fixation to surface-conjugated ligands plays a critical role in determining the fate of targeted colloidal particles after intravenous injection. In the present study, we examined the immunogenicity of targeted microbubbles with various surface architectures and ligand surface densities using a flow cytometry technique. Targeted microbubbles were generated using a post-labeling technique with a physiological targeting ligand, cyclic arginine-glycine-asparagine (RGD), attached to the distal end of the poly(ethylene glycol) (PEG) moieties on the microbubble surface. Microbubbles were incubated in human serum, washed and then mixed with fluorescent antibodies specific for various serum components. We found that complement C3/C3b was the main human serum factor to bind in vitro to the microbubble surface, compared to IgG or albumin. We also investigated the effect of PEG brush architecture on C3/C3b fixation to the microbubble surface. RGD peptide was able to trigger a complement immune response, and complement C3/C3b fixation depended on microbubble size and RGD peptide surface density. When the targeting ligand was attached to shorter PEG chains that were shielded by a PEG overbrush layer (buried-ligand architecture), significantly less complement activation was observed when compared to the more traditional exposed-ligand motif. The extent of this protective role by the PEG chains depended on the overbrush length. Taken together, our results confirm that the buried-ligand architecture may significantly reduce ligand-mediated immunogenicity. More generally, this study illustrates the use of flow cytometry and microbubbles to analyze the surface interactions between complex biological media and surface-engineered biomaterials. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:6579 / 6587
页数:9
相关论文
共 47 条
[1]   scVEGF Microbubble Ultrasound Contrast Agents A Novel Probe for Ultrasound Molecular Imaging of Tumor Angiogenesis [J].
Anderson, Christopher R. ;
Rychak, Joshua J. ;
Backer, Marina ;
Backer, Joseph ;
Ley, Klaus ;
Klibanov, Alexander L. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (10) :579-585
[2]  
[Anonymous], 2006, Molecular cell biology
[3]  
Borden M.A., 2008, Molecular Imaging in Oncology, V1, P329
[4]   A stimulus-responsive contrast agent for ultrasound molecular imaging [J].
Borden, Mark A. ;
Zhang, Hua ;
Gillies, Robert J. ;
Dayton, Paul A. ;
Ferrara, Katherine W. .
BIOMATERIALS, 2008, 29 (05) :597-606
[5]   Ultrasound radiation force modulates ligand availability on targeted contrast agents [J].
Borden, Mark A. ;
Sarantos, Melissa R. ;
Stieger, Susanne M. ;
Simon, Scott I. ;
Ferrara, Katherine W. ;
Dayton, Paul A. .
MOLECULAR IMAGING, 2006, 5 (03) :139-147
[6]   Ligand Conjugation to Bimodal Poly(ethylene glycol) Brush Layers on Microbubbles [J].
Chen, Cherry C. ;
Borden, Mark A. .
LANGMUIR, 2010, 26 (16) :13183-13194
[7]   Peptide-based molecules in angiogenesis [J].
D'Andrea, LD ;
Del Gatto, A ;
Pedone, C ;
Benedetti, E .
CHEMICAL BIOLOGY & DRUG DESIGN, 2006, 67 (02) :115-126
[8]  
Dijkmans P A, 2004, Eur J Echocardiogr, V5, P245, DOI 10.1016/j.euje.2004.02.001
[9]   Ultrasound microbubble contrast agents: Fundamentals and application to gene and drug delivery [J].
Ferrara, Katherine ;
Pollard, Rachel ;
Borden, Mark .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2007, 9 :415-447
[10]   Microbubble size isolation by differential centrifugation [J].
Feshitan, Jameel A. ;
Chen, Cherry C. ;
Kwan, James J. ;
Borden, Mark A. .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2009, 329 (02) :316-324