Efficient 3D TOF PET Reconstruction Using View-Grouped Histo-Images: DIRECT - Direct Image Reconstruction for TOF

被引:0
作者
Matej, Samuel [1 ]
Jayanthi, Shridhar [1 ]
Surti, Suleman [1 ]
Daube-Witherspoon, Margaret E. [1 ]
Muehllehner, Gerd [1 ]
Karp, Joel S. [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
来源
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6 | 2006年
关键词
List-mode; Time-Of-Flight; PET; iterative reconstruction; image space reconstruction;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For modern Time-Of-Flight (TOF) Positron Emission Tomography (PET) systems, in which the number of possible lines of response (LOR) and TOF bins is much larger than the number of acquired events, the most appropriate reconstruction approaches are considered to be the list-mode ones, where the processing of the acquired data is done event by event. However, their shortcomings are relatively high computational costs for reconstruction and sensitivity matrix calculation. Furthermore, new sensitivity matrix has to be calculated for each (attenuation) object, and all possible LORs have to be considered for its calculation, not only those which concide with the actually detected events. Efficient treatment of the TOF data within the proposed DIRECT - Direct Image Reconstruction for TOF - approach is allowed by 1) proper angular (polar and co-polar) grouping of the TOF events to a set of views as given by angular sampling requirements for TOF resolution - each view having a common TOF kernel, and 2) placement/deposit of the grouped events, and all correction data, into the "histo-images" (one histo-image per view), having the same geometry (voxel grid and orientation) as the reconstructed image. Unlike binning, proper storing operation does not compromise resolution of the data since events are directly stored into the histo-image elements at desired image (voxel) resolution. The reconstruction operations do not negatively affect the resolution neither since no tracing or interpolation operations are needed - all data and operations are directly in the image space. Very efficient reconstruction operations and calculation of correction coefficients can be designed utilizing the image equivalent format and grouping, as demonstrated in this work using DIRECT approach with iterative Row-Action Maximum-Likelihood (RAMLA) algorithm.
引用
收藏
页码:1728 / 1735
页数:8
相关论文
共 24 条
[11]   Iterative tomographic image reconstruction using Fourier-based forward and back-projectors [J].
Matej, S ;
Fessler, JA ;
Kazantsev, IG .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (04) :401-412
[12]   Fourier-based reconstruction for fully 3-D PET: Optimization of interpolation parameters [J].
Matej, Samuel ;
Kazantsev, Ivan G. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) :845-854
[13]  
*NEMA, 2001, NEMA STAND PUBL
[14]   List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PET [J].
Parra, L ;
Barrett, HH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (02) :228-235
[15]   IMAGE-RECONSTRUCTION OF DATA FROM SUPER PETT .1. A 1ST-GENERATION TIME-OF-FLIGHT POSITRON-EMISSION TOMOGRAPH [J].
POLITTE, DG ;
HOFFMAN, GR ;
BEECHER, DE ;
FICKE, DC ;
HOLMES, TJ ;
TERPOGOSSIAN, MM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :428-434
[16]  
Popescu LM, 2004, IEEE NUCL SCI CONF R, P3536
[17]   Fast accurate iterative reconstruction for low-statistics positron volume imaging [J].
Reader, AJ ;
Erlandsson, K ;
Flower, MA ;
Ott, RJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) :835-846
[18]   A MATHEMATICAL-MODEL FOR POSITRON-EMISSION TOMOGRAPHY SYSTEMS HAVING TIME-OF-FLIGHT MEASUREMENTS [J].
SNYDER, DL ;
THOMAS, LJ ;
TERPOGOSSIAN, MM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (03) :3575-3583
[19]   IMAGE-RECONSTRUCTION FROM LIST-MODE DATA IN AN EMISSION TOMOGRAPHY SYSTEM HAVING TIME-OF-FLIGHT MEASUREMENTS [J].
SNYDER, DL ;
POLITTE, DG .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (03) :1843-1849
[20]   Investigation of time-of-flight benefit for fully 3-D PET [J].
Surti, S ;
Karp, JS ;
Popescu, LA ;
Daube-Witherspoon, ME ;
Werner, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (05) :529-538