Ultrasound-determined diameter measurements are more accurate than axial computed tomography after endovascular aortic aneurysm repair

被引:23
作者
Han, Sukgn M. [1 ]
Patel, Kaushel [2 ]
Rowe, Vincent L. [1 ]
Perese, Susana [1 ]
Bond, Aaron [1 ]
Weaver, Fred A. [1 ]
机构
[1] Univ So Calif, Div Vasc Surg & Endovasc Therapy, CardioVasc Thorac Inst, Los Angeles, CA 90033 USA
[2] Kaiser Sunset Med Ctr, Dept Surg, Los Angeles, CA USA
关键词
INTEROBSERVER VARIABILITY;
D O I
10.1016/j.jvs.2010.01.033
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study evaluated the correlation of ultrasound (US)-derived aortic aneurysm diameter measurements with centerline, three-dimensional (3-D) reconstruction computed tomography (CT) measurements after endovascular aortic aneurysm repair (EVAR). Methods: Concurrent CT and US examinations from 82 patients undergoing post-EVAR surveillance were reviewed. The aortic aneurysm diameter was defined as the major axis on the centerline images of 3-D CT reconstruction. This was compared with US-derived minor and major axis measurements, as well as with the minor axis measurement on the conventional axial CT images. Correlation was evaluated with linear regression analyses. Agreement between different imaging modalities and measurements was assessed with Bland-Altman plots. Results: The correlation coefficients from linear regression analyses were 0.92 between CT centerline major and US minor measurements, 0.94 between CT centerline major and US major measurements, and 0.93 between CT minor and centerline major measurements. Bland-Altman plots showed a mean difference of 0.11 mm between US major and CT centerline measurements compared with 5.38 mm between US minor and CT centerline measurements, and 4.25 mm between axial CT minor and centerline measurements. This suggested that, compared with axial CT and US minor axis measurements, US major axis measurements were in better agreement with CT centerline measurements. Variability between major and minor US and CT centerline diameter measurements was high (standard deviation of difference, 4.27-4.84 mm). However, high variability was also observed between axial CT measurements and centerline CT measurements (standard deviation of difference, 4.36 mm). Conclusions: The major axis aneurysm diameter measurement obtained by US imaging for surveillance after EVAR correlates well and is in better agreement with centerline 3-D CT reconstruction diameters than axial CT. (J Vase Surg 2010;51:1381-9.)
引用
收藏
页码:1381 / 1389
页数:9
相关论文
共 16 条
[1]   Abdominal aortic aneurysm measurements for endovascular repair: Intra- and interobserver variability of CT measurements [J].
Aarts, NJM ;
Schurink, GWH ;
Kool, LJS ;
Bode, PJ ;
van Baalen, JM ;
Hermans, J ;
van Bockel, JH .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1999, 18 (06) :475-480
[2]  
[Anonymous], 1995, Eur J Vasc Endovasc Surg, V9, P42
[3]   The Multicentre Aneurysm Screening Study (MASS) into the effect of abdominal aortic aneurysm screening on mortality in men: a randomised controlled trial [J].
Ashton, HA ;
Buxton, MJ ;
Day, NE ;
Kim, LG ;
Marteau, TM ;
Scott, RAP ;
Thomspon, SG ;
Walker, NM .
LANCET, 2002, 360 (9345) :1531-1539
[4]  
Balm R, 1997, TEX HEART I J, V24, P200
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Variability of maximal aortic aneurysm diameter measurements on CT scan: Significance and methods to minimize [J].
Cayne, NS ;
Veith, FJ ;
Lipsitz, EC ;
Ohki, T ;
Mehta, M ;
Gargiulo, N ;
Suggs, WD ;
Rozenblit, A ;
Ricci, Z ;
Timaran, CH .
JOURNAL OF VASCULAR SURGERY, 2004, 39 (04) :811-815
[7]   Reporting standards for endovascular aortic aneurysm repair [J].
Chaikof, EL ;
Blankensteijn, JD ;
Harris, PL ;
White, GH ;
Zarins, CK ;
Bernhard, VM ;
Matsumura, JS ;
May, J ;
Veith, FJ ;
Fillinger, MF ;
Rutherford, RB ;
Kent, KC .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (05) :1048-1060
[8]   Follow-up evaluation of endoluminally treated abdominal aortic aneurysms with duplex ultrasonography: Validation with computed tomography [J].
d'Audiffret, A ;
Desgranges, P ;
Kobeiter, DH ;
Becquemin, JP .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (01) :42-49
[9]   Interobserver variability in measuring the dimensions of the abdominal aorta: Comparison of ultrasound and computed tomography [J].
Jaakkola, P ;
Hippelainen, M ;
Farin, P ;
Rytkonen, H ;
Kainulainen, S ;
Partanen, K .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1996, 12 (02) :230-237
[10]   VARIABILITY IN MEASUREMENT OF ABDOMINAL AORTIC-ANEURYSMS [J].
LEDERLE, FA ;
WILSON, SE ;
JOHNSON, GR ;
REINKE, DB ;
LITTOOY, FN ;
ACHER, CW ;
MESSINA, LM ;
BALLARD, DJ ;
ANSEL, HJ .
JOURNAL OF VASCULAR SURGERY, 1995, 21 (06) :945-952