Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: A biomechanical study

被引:25
作者
Zhou, Lin [1 ,7 ]
Lin, Jiaming [2 ]
Huang, Anfei [3 ]
Gan, Weidong [3 ]
Zhai, Xu [4 ]
Sun, Kai [5 ]
Huang, Shiqing [6 ,7 ]
Li, Zhizhong [1 ,7 ]
机构
[1] Jinan Univ, Dept Orthoped, Affiliated Hosp 1, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ, Collaborat Innovat Ctr Canc Med, Dept Musculoskeletal Oncol, State Key Lab Oncol South China,Canc Ctr, Guangzhou, Peoples R China
[3] Jinan Univ, Clin Med Coll 1, Guangzhou, Peoples R China
[4] 903rd Hosp PLA, Dept Orthoped, Hangzhou, Peoples R China
[5] Jiujiang Univ, Jiujiang Univ Hosp, Clin Med Coll, Jiujiang, Peoples R China
[6] Jinan Univ, Sch Mechan & Construct Engn, Guangzhou, Peoples R China
[7] Clin Biomech & Biomimet Mat Res Ctr, Guangzhou, Guangdong, Peoples R China
关键词
Femoral neck fracture; Cannulated screw; Biomechanics; FIXED-ANGLE DEVICES; YOUNG-ADULTS; COMPLICATIONS;
D O I
10.1016/j.clinbiomech.2020.02.016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Achieving satisfactory internal fixation for patients with Pauwels type III femoral neck fractures has become a critical problem. The purpose of this study was to compare a common standard internal reduction and fixation method for femoral neck fractures to the modified fixation methods. Methods: A computed tomography scan of the femur was performed to make a Three-dimensional (3D) model, and a fracture line was simulated in the femoral neck. 3Dfinite element analysis was carried out for different insertion methods of cannulated tension screws. Six healthy femur specimens were harvested from three formalin-fixed cadavers, and Pauwels type III femoral neck fracture was artificially created in bilateral femurs. The right side was treated with the inverted triangle construct method and the left side by the modified screw fixation method. After fixation, uniaxial compression and maximum load experiments on the bilateral femoral necks were carried out using the non-contact full-field dynamic strain measurement system (VIC-3D) on a pressure testing machine. Findings: Both 3D finite element analysis and biomechanical study showed that the modified screw fixation method(group D) provided better anti-shearing and anti-rotation properties for Pauwels type III femoral neck fractures, and offered better interfragmentary compression. Therefore, this modified screw fixation method can offer patients a better option for treatment of Pauwels type III femoral neck fractures. Interpretation: Changing the placement of the anterosuperior screw in the inverted triangle construct as perpendicular to the fracture line has the advantages in anti-shearing, anti-rotation and increasing interfragmentary compression.
引用
收藏
页码:103 / 110
页数:8
相关论文
共 25 条
  • [1] Vertically oriented femoral neck fractures: Mechanical analysis of four fixation techniques
    Aminian, Arash
    Gao, Fan
    Fedoriw, Wasyl W.
    Zhang, Li-Qun
    Kalainov, David M.
    Merk, Bradley R.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (08) : 544 - 548
  • [2] COMPLICATIONS OF FEMORAL-NECK FRACTURE IN YOUNG-ADULTS
    DEDRICK, DK
    MACKENZIE, JR
    BURNEY, RE
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1986, 26 (10) : 932 - 937
  • [3] Fracture healing and bone repair
    Giannoudis, Peter V.
    Jones, Elena
    Einhorn, Thomas A.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (06): : 549 - 550
  • [4] Does a trochanteric lag screw improve fixation of vertically oriented femoral neck fractures? A biomechanical analysis in cadaveric bone
    Hawks, Michael A.
    Kim, Hyunchul
    Strauss, Joseph E.
    Oliphant, Bryant W.
    Golden, Robert D.
    Hsieh, Adam H.
    Nascone, Jason W.
    O'Toole, Robert V.
    [J]. CLINICAL BIOMECHANICS, 2013, 28 (08) : 886 - 891
  • [5] Effect of Depression on Femoral Head Avascular Necrosis From Femoral Neck Fracture in Patients Younger Than 60 Years
    He, Dong
    Xue, Yuan
    Li, ZhiYang
    Tang, YanMing
    Ding, HuaiRong
    Yang, Zhong
    Zhang, Chao
    Zhou, HuiFang
    Zhao, Ying
    Zong, YaQi
    [J]. ORTHOPEDICS, 2014, 37 (03) : E244 - E251
  • [6] Fixation of displaced femoral neck fractures in young adults: Fixed-angle devices or Pauwel screws?
    Hoshino, C. M.
    Christian, M. W.
    O'Toole, R. V.
    Manson, T. T.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (08): : 1676 - 1684
  • [7] Fixed angle devices versus multiple cancellous screws: What does the evidence tell us?
    Hoshino, C. Max
    O'Toole, Robert V.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (03): : 474 - 477
  • [8] Lichtblau S, 2008, BULL HOSP JT DIS, V66, P269
  • [9] Results of internal fixation of Pauwels type-3 vertical femoral neck fractures
    Liporace, Frank
    Gaines, Robert
    Collinge, Cory
    Haidukewych, George J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (08) : 1654 - 1659
  • [10] Vertical femoral neck fractures in young adults: a closed fixation strategy using a transverse cancellous lag screw
    Matheus Guimaraes, Joao Antonio
    Rocha, Leonardo Rosa
    Noronha Rocha, Tito Henrique
    Bonfim, Danielle Cabral
    da Costa, Rafaela Sartore
    Cavalcanti, Amanda dos Santos
    Roesler, Carlos Rodrigo
    Perini Machado, Jamila Alessandra
    Aguiar, Diego Pinheiro
    Leite Duarte, Maria Eugenia
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 : S10 - S16