Calorimeter prototype based on silicon drift detectors coupled to scintillators for Compton telescopes application

被引:6
作者
Marisaldi, M
Labanti, C
Bulgarelli, A
Celesti, E
Di Cocco, G
Gianotti, F
Mauri, A
Rossi, E
Traci, A
Trifoglio, M
机构
[1] CNR, IASF Sez Bologna, I-40129 Bologna, Italy
[2] Univ Bologna, Dipartmento Fis, I-40127 Bologna, Italy
关键词
silicon drift detectors; Compton telescopes;
D O I
10.1016/j.newar.2003.11.035
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The project of a new calorimeter module for Compton telescopes based on an array of silicon drift detectors (SDD) coupled to thallium activated cesium iodide (CsI(Tl)) scintillating crystals is presented. Because of their low output Is capacitance and the possibility to have the first amplifying stage directly integrated on chip, SDDs show better noise performances than traditional p-intrinsic-n (PIN) photodiodes. For this reason, SDDs coupled to scintillators show a higher energy resolution than similar systems based on PIN photodiodes. The detectors will be integrated in an array with read-out based on custom made ASIC's built to match with the SDDs electrical properties. Shaped signals are digitally converted by a Digital Front-End Electronic Board which also takes care of ASICs handshaking. The system architecture is based on the PICsIT instrument on board the INTEGRAL satellite, at present fully operative. In this paper an overview of the instrument will be given and the status of the project will be reported. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:305 / 308
页数:4
相关论文
共 7 条
[1]   The MEGA advanced Compton telescope project [J].
Bloser, PF ;
Andritschke, R ;
Kanbach, G ;
Schönfelder, V ;
Schopper, F ;
Zoglauer, A .
NEW ASTRONOMY REVIEWS, 2002, 46 (8-10) :611-616
[2]   First experimental results of a new gamma-ray detector based on a Silicon Drift Chamber coupled to a scintillator [J].
Fiorini, C ;
Longoni, A ;
Perotti, F ;
Labanti, C ;
Lechner, P ;
Struder, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :395-399
[3]   SEMICONDUCTOR DRIFT CHAMBER - AN APPLICATION OF A NOVEL CHARGE TRANSPORT SCHEME [J].
GATTI, E ;
REHAK, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (03) :608-614
[4]  
KANBACH G, 2002, P SPIE ASTR TEL INST
[5]   ICARUS ASIC: A 16 channel photo diode read out system [J].
Labanti, C ;
Rossi, E ;
Mauri, A ;
Bastia, P ;
Foglia, L ;
Krummenacher, F ;
Valence, V .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :144-149
[6]   PICsIT: a position sensitive detector for space applications [J].
Labanti, C ;
Di Cocco, G ;
Malaguti, G ;
Stephen, JB ;
Rossi, E ;
Schiavone, F ;
Traci, A ;
Ferro, G ;
Ferriani, S ;
Mauri, A ;
Visparelli, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3) :561-566
[7]  
LABANTI C, 2000, NUCL SCI S 2000 C RE