The design of a new concept chromatography column

被引:43
作者
Camenzuli, Michelle [2 ]
Ritchie, Harald J. [1 ]
Ladine, James R. [1 ]
Shalliker, R. Andrew [1 ,2 ]
机构
[1] Thermo Fisher Sci, Runcorn, Cheshire, England
[2] Univ Western Sydney Parramatta, Sch Nat Sci, ACROSS, Sydney, NSW, Australia
关键词
LIQUID-CHROMATOGRAPHY; DISPERSION; EFFICIENCY; ELECTRODES; BAND;
D O I
10.1039/c1an15681k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Active Flow Management is a new separation technique whereby the flow of mobile phase and the injection of sample are introduced to the column in a manner that allows migration according to the principles of the infinite diameter column. A segmented flow outlet fitting allows for the separation of solvent or solute that elutes along the central radial section of the column from that of the sample or solvent that elutes along the wall region of the column. Separation efficiency on the analytical scale is increased by 25% with an increase in sensitivity by as much as 52% compared to conventional separations.
引用
收藏
页码:5127 / 5130
页数:4
相关论文
共 13 条
[1]   MICROCYLINDER ELECTRODES AS SENSITIVE DETECTORS FOR HIGH-EFFICIENCY, HIGH-SPEED LIQUID-CHROMATOGRAPHY [J].
BAUR, JE ;
WIGHTMAN, RM .
JOURNAL OF CHROMATOGRAPHY, 1989, 482 (01) :65-73
[2]   RADIAL DISPERSION FROM COMMERCIAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS INVESTIGATED WITH MICROVOLTAMMETRIC ELECTRODES [J].
BAUR, JE ;
KRISTENSEN, EW ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1988, 60 (21) :2334-2338
[3]   Visualization of solute migration in chromatographic columns - Influence of the frit porosity [J].
Broyles, BS ;
Shalliker, RA ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2001, 917 (1-2) :1-22
[4]   COMPARISON OF BROADENING PATTERNS IN REGULAR AND RADIALLY COMPRESSED LARGE-DIAMETER COLUMNS [J].
EON, CH .
JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB) :29-42
[5]   Contribution of the radial distribution of the flow velocity to band broadening in HPLC columns [J].
Farkas, T ;
Guiochon, G .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4592-4600
[6]   COLUMN EFFICIENCY AND RADIAL HOMOGENEITY IN LIQUID-CHROMATOGRAPHY [J].
FARKAS, T ;
CHAMBERS, JQ ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY A, 1994, 679 (02) :231-245
[7]   Measurement of the axial and radial temperature profiles of a chromatographic column - Influence of thermal insulation on column efficiency [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1138 (1-2) :141-157
[8]   EFFECT OF COLUMN TO PARTICLE DIAMETER RATIO ON DISPERSION OF UNSORBED SOLUTES IN CHROMATOGRAPHY [J].
KNOX, JH ;
PARCHER, JF .
ANALYTICAL CHEMISTRY, 1969, 41 (12) :1599-&
[9]   INTERACTION OF RADIAL AND AXIAL-DISPERSION IN LIQUID-CHROMATOGRAPHY IN RELATION TO INFINITE DIAMETER EFFECT [J].
KNOX, JH ;
LAIRD, GR ;
RAVEN, PA .
JOURNAL OF CHROMATOGRAPHY, 1976, 122 (JUL7) :129-145
[10]   Solvent viscosity mismatch between the solute plug and the mobile phase: Considerations in the applications of two-dimensional HPLC [J].
Shalliker, R. Andrew ;
Guiochon, Georges .
ANALYST, 2010, 135 (02) :222-229