An electronic nose distinguishes exhaled breath of patients with Malignant Pleural Mesothelioma from controls

被引:104
作者
Dragonieri, Silvano [1 ,2 ]
van der Schee, Marc P. [2 ]
Massaro, Tommaso [3 ]
Schiavulli, Nunzia [3 ]
Brinkman, Paul [2 ]
Pinca, Armando [3 ]
Carratu, Pierluigi [1 ]
Spanevello, Antonio [4 ]
Resta, Onofrio [1 ]
Musti, Marina [3 ]
Sterk, Peter J. [2 ]
机构
[1] Univ Bari, Dept Resp Dis, I-70100 Bari, Italy
[2] Univ Amsterdam, Acad Med Ctr, Dept Resp Med, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Bari, Dept Occupat Med, I-70100 Bari, Italy
[4] Fdn Maugeri, Dept Pulmonol, Tradate, Italy
关键词
Biomarkers; Malignant Pleural Mesothelioma; Asbestos exposure; Electronic nose; Exhaled breath; Volatile organic compounds; VOLATILE ORGANIC-COMPOUNDS; LUNG-CANCER; CLINICAL-APPLICATION; VAPOR; DIAGNOSIS; ARRAY; DISCRIMINATION; PERFORMANCE; BIOMARKERS; PNEUMONIA;
D O I
10.1016/j.lungcan.2011.08.009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Malignant Pleural Mesothelioma (MPM) is a tumour of the surface cells of the pleura that is highly aggressive and mainly caused by asbestos exposure. Electronic noses capture the spectrum of exhaled volatile organic compounds (VOCs) providing a composite biomarker profile (breathprint). Objective: We tested the hypothesis that an electronic nose can discriminate exhaled air of patients with,MPM from subjects with a similar long-term professional exposure to asbestos without MPM and from healthy controls. Methods: 13 patients with a histology confirmed diagnosis of MPM (age 60.9 +/- 12.2 year), 13 subjects with certified, long-term professional asbestos exposure (age 67.2 +/- 9.8), and 13 healthy subjects without asbestos exposure (age 52.2 +/- 16.2) participated in a cross-sectional study. Exhaled breath was collected by a previously described method and sampled by an electronic nose (Cyranose 320). Breathprints were analyzed by canonical discriminant analysis on principal component reduction. Cross-validated accuracy (CVA) was calculated. Results: Breathprints from patients with MPM were separated from subjects with asbestos exposure (CVA: 80.8%, sensitivity 92.3%, specificity 85.7%). MPM was also distinguished from healthy controls (CVA: 84.6%). Repeated measurements confirmed these results. Conclusions: Molecular pattern recognition of exhaled breath can correctly distinguish patients with MPM from subjects with similar occupational asbestos exposure without MPM and from healthy controls. This suggests that breathprints obtained by electronic nose have diagnostic potential for MPM. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:326 / 331
页数:6
相关论文
共 42 条
[1]  
Baylin SB, 1998, ADV CANCER RES, V72, P141
[2]  
Bianchi C, 1997, AM J IND MED, V32, P445, DOI 10.1002/(SICI)1097-0274(199711)32:5<445::AID-AJIM3>3.3.CO
[3]  
2-B
[4]   Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Lijmer, JG ;
Moher, D ;
Rennie, D ;
de Vet, HCW .
ANNALS OF INTERNAL MEDICINE, 2003, 138 (01) :40-44
[5]   Exploitation of spatiotemporal information and geometric optimization of signal/noise performance using arrays of carbon black-polymer composite vapor detectors [J].
Briglin, SM ;
Freund, MS ;
Tokumaru, P ;
Lewis, NS .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 82 (01) :54-74
[6]  
Broadhurst DI, 2007, METABOLOMICS, V2, P4
[7]   Chemical characterization of exhaled breath to differentiate between patients with malignant plueral mesothelioma from subjects with similar professional asbestos exposure [J].
de Gennaro, G. ;
Dragonieri, S. ;
Longobardi, F. ;
Musti, M. ;
Stallone, G. ;
Trizio, L. ;
Tutino, M. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (7-8) :3043-3050
[8]   The Mahalanobis distance [J].
De Maesschalck, R ;
Jouan-Rimbaud, D ;
Massart, DL .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 50 (01) :1-18
[9]   Lung cancer identification by the analysis of breath by means of an array of non-selective gas sensors [J].
Di Natale, C ;
Macagnano, A ;
Martinelli, E ;
Paolesse, R ;
D'Arcangelo, G ;
Roscioni, C ;
Finazzi-Agrò, A ;
D'Amico, A .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (10) :1209-1218
[10]   An electronic nose in the discrimination of patients with asthma and controls [J].
Dragonieri, Silvano ;
Schot, Robert ;
Mertens, Bart J. A. ;
Le Cessie, Saskia ;
Gauw, Stefanie A. ;
Spanevello, Antonio ;
Resta, Onofrio ;
Willard, Nico P. ;
Vink, Teunis J. ;
Rabe, Klaus F. ;
Bel, Elisabeth H. ;
Sterk, Peter J. .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2007, 120 (04) :856-862