Multiple resolution chirp reflectometry for fault localization and diagnosis in a high voltage cable in automotive electronics

被引:6
作者
Chang, Seung Jin [1 ]
Lee, Chun Ku [1 ]
Shin, Yong-June [1 ]
Park, Jin Bae [1 ]
机构
[1] Yonsei Univ, Dept Elect & Elect Engn, Seoul 120749, South Korea
基金
新加坡国家研究基金会;
关键词
cable fault localization; multiple chirp signals; normalized cross-correlation; reflection coefficient; multiple resolution; fault estimation; FREQUENCY DOMAIN REFLECTOMETRY; LOCATION;
D O I
10.1088/0957-0233/27/12/125006
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A multiple chirp reflectometry system with a fault estimation process is proposed to obtain multiple resolution and to measure the degree of fault in a target cable. A multiple resolution algorithm has the ability to localize faults, regardless of fault location. The time delay information, which is derived from the normalized cross-correlation between the incident signal and bandpass filtered reflected signals, is converted to a fault location and cable length. The in-phase and quadrature components are obtained by lowpass filtering of the mixed signal of the incident signal and the reflected signal. Based on in-phase and quadrature components, the reflection coefficient is estimated by the proposed fault estimation process including the mixing and filtering procedure. Also, the measurement uncertainty for this experiment is analyzed according to the Guide to the Expression of Uncertainty in Measurement. To verify the performance of the proposed method, we conduct comparative experiments to detect and measure faults under different conditions. Considering the installation environment of the high voltage cable used in an actual vehicle, target cable length and fault position are designed. To simulate the degree of fault, the variety of termination impedance (10 Omega, 30 Omega, 50 Omega, and 1 k Omega) are used and estimated by the proposed method in this experiment. The proposed method demonstrates advantages in that it has multiple resolution to overcome the blind spot problem, and can assess the state of the fault.
引用
收藏
页数:8
相关论文
共 20 条
[1]  
[Anonymous], 2005, Radar Systems Analysis and Design using MATLAB
[2]  
[Anonymous], 1995, EVALUATION MEASUREME
[3]  
Auzanneau Fabrice, 2013, Progress In Electromagnetics Research B, V49, P253
[4]   Frequency-domain reflectometery for on-board testing of aging aircraft wiring [J].
Furse, C ;
Chung, YC ;
Dangol, R ;
Nielsen, M ;
Mabey, G ;
Woodward, R .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2003, 45 (02) :306-315
[5]   Down to the Wire [J].
Furse, C ;
Haupt, R .
IEEE SPECTRUM, 2001, 38 (02) :34-+
[6]   The invisible fray: A critical analysis of the use of reflectometry for fray location [J].
Griffiths, LA ;
Parakh, R ;
Furse, C ;
Baker, B .
IEEE SENSORS JOURNAL, 2006, 6 (03) :697-706
[7]   State-of-the-Art Predictive Maintenance Techniques [J].
Hashemian, H. M. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (01) :226-236
[8]  
Lawrenz W., 1997, CAN System Engineering: From Theory to Practical Applications
[9]  
Lee C.-K., 2015, 9 INT C INS POW CABL
[10]   Non-invasive monitoring of underground power cables using Gaussian-enveloped chirp reflectometry [J].
Lee, Chun Ku ;
Lee, Sin Ho ;
Chang, Seung Jin ;
Park, Jin Bae ;
Yoon, Tae Sung .