Binocular Shack-Hartmann sensor for the human eye

被引:19
作者
Hampson, K. M. [1 ]
Chin, S. S. [1 ]
Mallen, E. A. H. [1 ]
机构
[1] Univ Bradford, Dept Optometry, Bradford BD7 1DP, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
open-view binocular Shack-Hartmann sensor; coherence function analysis;
D O I
10.1080/09500340701469674
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
During steady-state fixation the aberrations of the human eye display dynamic behaviour. It has been suggested that the fluctuations in focus are correlated between both eyes. However, nothing is known about the dynamic correlation between the aberrations other than focus. We have developed an open-view binocular Shack-Hartmann sensor which measures the ocular wavefront aberrations simultaneously in both eyes at 25 Hz. A single sensor and laser source are used to reduce system cost and complexity. Speckle is reduced using a rotating diffuser in a plane conjugate to the retinae. We measured the wavefront dynamics of two subjects and decomposed the data into Zernike aberration terms up to and including fifth radial order. Coherence function analysis was used to determine the correlation between aberrations in the frequency domain. The correlations were dependent upon subject, frequency and aberration type.
引用
收藏
页码:703 / 716
页数:14
相关论文
共 24 条
[1]  
Bendat J.S., 2000, RANDOM DATA ANAL MEA
[2]  
*BRIT STAND, 1994, 608251 BS
[3]   CORRELATION OF ACCOMMODATION BETWEEN THE 2 EYES [J].
CAMPBELL, FW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1960, 50 (07) :738-738
[4]  
Castejón-Mochón JF, 2002, VISION RES, V42, P1611, DOI 10.1016/S0042-6989(02)00085-8
[5]  
Collins G, 1937, BR J PHYSL OPT, V1, P30
[6]   Benefit of higher closed-loop bandwidths in ocular adaptive optics [J].
Diaz-Santana, L ;
Torti, C ;
Munro, I ;
Gasson, P ;
Dainty, C .
OPTICS EXPRESS, 2003, 11 (20) :2597-2605
[8]   Adaptive optics system for investigation of the effect of the aberration dynamics of the human eye on steady-state accommodation control [J].
Hampson, KM ;
Paterson, C ;
Dainty, C ;
Mallen, EAH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2006, 23 (05) :1082-1088
[9]   Coherence function analysis of the higher-order aberrations of the human eye [J].
Hampson, KM ;
Mallen, EAH ;
Dainty, C .
OPTICS LETTERS, 2006, 31 (02) :184-186
[10]   Weak correlation between the aberration dynamics of the human eye and the cardiopulmonary system [J].
Hampson, KM ;
Munro, I ;
Paterson, C ;
Dainty, C .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2005, 22 (07) :1241-1250