Comparison of simultaneous continuous intracranial pressure (ICP) signals from ICP sensors placed within the brain parenchyma and the epidural space

被引:36
作者
Eide, Per Kristian [1 ]
机构
[1] Natl Hosp Norway, Rikshosp, Dept Neurosurg, N-0027 Oslo, Norway
关键词
intracranial pressure; epidural pressure; brain parenchyma pressure; single ICP waves;
D O I
10.1016/j.medengphy.2007.01.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Simultaneous continuous intracranial pressure (ICP) signals from two different ICP sensors (Codman ICP MicroSensor; Johnson & Johnson, Raynham, MA) placed within the brain parenchyma and the epidural space were compared in ten patients with idiopathic normal pressure hydrocephalus (iNPH). Comparisons were made at the single ICP wave level by detennining differences in mean pressure, and pulse pressure amplitude (dP) and latency (dT, i.e. rise time). Differences for the parameters mean ICP, mean ICP wave amplitude and mean ICP wave latency were also determined during consecutive 6-s time windows. The ICP sensors located within the brain parenchyma and epidural space showed marked differences in mean pressure. On the contrary, there were minor differences between sensors in 8 of 10 patients regarding single wave pulse pressure amplitude (dP) and single wave latency (dT, i.e. rise time), and also with regard to the parameters mean ICP wave amplitude and mean ICP wave latency. The levels of mean ICP wave amplitudes used for predicting shunt response in iNPH patients were independent of sensor location in 9 of 10 patients. These results extend previous data that epidural ICP monitoring cannot be used to reliably determine mean ICP, however, epidural ICP monitoring is very useful for determining ICP waveform parameters such as pulse pressure amplitude (dP) and mean ICP wave amplitude. It is suggested that epidural ICP monitoring with determination of mean ICP wave amplitude can be used to predict shunt response in iNPH, though an ICP sensor designed for epidural ICP monitoring would be preferable. (c) 2007 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 19 条
[1]   An automatic beat detection algorithm for pressure signals [J].
Aboy, M ;
McNames, J ;
Thong, T ;
Tsunami, D ;
Ellenby, MS ;
Goldstein, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (10) :1662-1670
[2]   A COMPARISON OF EXTRADURAL AND INTRAPARENCHYMATOUS INTRACRANIAL PRESSURES IN HEAD-INJURED PATIENTS [J].
BRUDER, N ;
NZOGHE, P ;
GRAZIANI, N ;
PELISSIER, D ;
GRISOLI, F ;
FRANCOIS, G .
INTENSIVE CARE MEDICINE, 1995, 21 (10) :850-852
[3]   Intracranial pulse pressure amplitude levels determined during preoperative assessment of subjects with possible idiopathic normal pressure hydrocephalus [J].
Eide, P. K. ;
Brean, A. .
ACTA NEUROCHIRURGICA, 2006, 148 (11) :1151-1156
[4]   Comparison of simultaneous continuous intracranial pressure (ICP) signals from a Codman and a Camino lCP sensor [J].
Eide, Per Kristian .
MEDICAL ENGINEERING & PHYSICS, 2006, 28 (06) :542-549
[5]   A new method for processing of continuous intracranial pressure signals [J].
Eide, Per Kristian .
MEDICAL ENGINEERING & PHYSICS, 2006, 28 (06) :579-587
[6]   Intracranial pressure parameters in idiopathic normal pressure hydrocephalus patients treated with ventriculo-peritoneal shunts [J].
Eide P.K. .
Acta Neurochirurgica, 2006, 148 (1) :21-29
[7]  
EIDE PK, IN PRESS NEUROL RES
[8]   PULSE AMPLITUDE AND VOLUME-PRESSURE RELATIONSHIPS IN EXPERIMENTAL HYDROCEPHALUS [J].
GONZALEZDARDER, JM ;
BARCIASALORIO, JL .
ACTA NEUROCHIRURGICA, 1989, 97 (3-4) :166-170
[9]   CHANGES IN INTRACRANIAL-PRESSURE AND EPIDURAL PULSE WAVEFORM FOLLOWING COLD INJURY [J].
HIRAI, O ;
HANDA, H ;
ISHIKAWA, M ;
KIM, SH ;
YOSHIDA, S .
ACTA NEUROCHIRURGICA, 1985, 77 (1-2) :14-21
[10]   EPIDURAL PULSE WAVEFORM AS AN INDICATOR OF INTRACRANIAL-PRESSURE DYNAMICS [J].
HIRAI, O ;
HANDA, H ;
ISHIKAWA, M ;
KIM, SH .
SURGICAL NEUROLOGY, 1984, 21 (01) :67-74