Can serum free light chains replace urine electrophoresis in the detection of monoclonal gammopathies?

被引:48
作者
Beetham, Robert [1 ]
Wassell, Julie [1 ]
Wallagel, Michael J. [1 ]
Whiteway, Alastair J. [2 ]
James, Jacky A. [2 ]
机构
[1] Frenchay Hosp, Dept Clin Biochem, N Bristol NHS, Bristol BS16 1LE, Avon, England
[2] Frenchay Hosp, Dept Clin Haematol, N Bristol NHS, Bristol BS16 1LE, Avon, England
关键词
MOLECULAR-WEIGHT PROTEINS; UNDETERMINED SIGNIFICANCE; MYELOMA; IMMUNOGLOBULINS; AMYLOIDOSIS;
D O I
10.1258/000456307782268084
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background We investigated how sensitive serum free light chain (FLC) analysis was for the detection of Bence-Jones protein (BJP) and whether a serum k/lambda. ratio could replace urine electrophoresis as part of the investigation algorithm for monoclonal gammopathy. Methods Serum K and lambda FLC analysis was performed on 932 consecutive patients investigated for monoclonal gammopathy, along with serum electrophoresis, serum immunofixation where appropriate, and in 483 individuals urine immunofixation. A reference interval for the ratio was derived from all patients who had normal serum and urine electrophoresis and no B-cell dyscrasia (n = 312). Results The 100% reference interval was 0.21-1.44 (median 0,50), lower than that previously published. From the 483 patients who provided urines, BJP was detected in 34, with an abnormal k/lambda ratio in 26 of these. Using the reference interval, sensitivity, specificity, negative and positive predictive values of an abnormal k/lambda. ratio for the presence of BJP were 0.76, 0.96, 0.98 and 0.59 respectively. Seven patients had an abnormal k/lambda ratio with no paraprotein. Conclusion All k/lambda results should be interpreted against a reference interval appropriate for the analyser in use and the population under study. Some urines will be positive for BJP when the serum k/lambda ratio is normal, but there is little difference in outcome whether urine for BJP or serum FLC analysis is included in the screening strategy for monoclonal gammopathies. On balance, we believe that it is not yet time to dispense with urine BJP in the investigation of patients with suspected monoclonal gammopathy.
引用
收藏
页码:516 / 522
页数:7
相关论文
共 22 条
[1]   Quantitative analysis of serum free light chains - A new marker for the diagnostic evaluation of primary systemic amyloidosis [J].
Abraham, RS ;
Katzmann, JA ;
Clark, RJ ;
Bradwell, AR ;
Kyle, RA ;
Gertz, MA .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2003, 119 (02) :274-278
[2]   Serum free light chain (FLC) measurement can aid capillary zone electrophoresis in detecting subtle FLC-producing M proteins [J].
Bakshi, NA ;
Gulbranson, R ;
Garstka, D ;
Bradwell, AR ;
Keren, DF .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2005, 124 (02) :214-218
[3]  
Bradwell AR, 2001, CLIN CHEM, V47, P673
[4]   Serum test for assessment of patients with Bence Jones myeloma [J].
Bradwell, AR ;
Carr-Smith, HD ;
Mead, GP ;
Harvey, TC ;
Drayson, MT .
LANCET, 2003, 361 (9356) :489-491
[5]  
Bradwell AR, 2006, SERUM FREE LIGHT CHA
[6]   Serum free light-chain measurements for identifying and monitoring patients with nonsecretory multiple myeloma [J].
Drayson, M ;
Tang, LX ;
Drew, R ;
Mead, GP ;
Carr-Smith, H ;
Bradwell, AR .
BLOOD, 2001, 97 (09) :2900-2902
[7]   Guidelines for the analysis of Bence Jones protein [J].
Graziani, M ;
Merlini, G ;
Petrini, C .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, 41 (03) :338-346
[8]   Serum free light chains: An alternative to the urine Bence Jones proteins screening test for monoclonal gammopathies [J].
Hill, Peter G. ;
Forsyth, Julia M. ;
Rai, Baldeep ;
Mayne, Stewart .
CLINICAL CHEMISTRY, 2006, 52 (09) :1743-1748
[9]  
Katzmann JA, 2002, CLIN CHEM, V48, P1437
[10]   Elimination of the need for urine studies in the screening algorithm for monoclonal gammopathies by using serum immunofixation and free light chain assays [J].
Katzmann, Jerry A. ;
Dispenzieri, Angela ;
Kyle, Robert A. ;
Snyder, Melissa R. ;
Plevak, Matthew F. ;
Larson, Dirk R. ;
Abraham, Roshini S. ;
Lust, John A. ;
Melton, L. Joseph, III ;
Rajkumar, S. Vincent .
MAYO CLINIC PROCEEDINGS, 2006, 81 (12) :1575-1578