Novel approaches to analysis by flow injection gradient titration

被引:13
作者
Wojtowicz, Marzena [1 ]
Kozak, Joanna [1 ]
Koscielniak, Pawel [1 ]
机构
[1] Jagiellonian Univ, Fac Chem, Dept Analyt Chem, PL-30060 Krakow, Poland
关键词
flow injection titration; calibration; fully rotary valve; acid-base titration;
D O I
10.1016/j.aca.2007.04.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two novel procedures for flow injection gradient titration with the use of a single stock standard solution are proposed. In the multi-point single-line (MP-SL) method the calibration graph is constructed on the basis of a set of standard solutions, which are generated in a standard reservoir and subsequently injected into the titrant. According to the single-point multi-line (SP-ML) procedure the standard solution and a sample are injected into the titrant stream from four loops of different capacities, hence four calibration graphs are able to be constructed and the analytical result is calculated on the basis of a generalized slope of these graphs. Both approaches have been tested on the example of spectrophotometric acid-base titration of hydrochloric and acetic acids with using bromothymol blue and phenolphthalein as indicators, respectively, and sodium hydroxide as a titrant. Under optimized experimental conditions the analytical results of precision less than 1.8 and 2.5% (RSD) and of accuracy less than 3.0 and 5.4% (relative error (RE)) were obtained for MP-SL and SPML procedures, respectively, in ranges of 0.0031-0.0631 mol L-1 for samples of hydrochloric acid and of 0.1680-1.7600 mol L-1 for samples of acetic acid. The feasibility of both methods was illustrated by applying them to the total acidity determination in vinegar samples with precision lower than 0.5 and 2.9% (RSD) for MP-SL and SP-ML procedures, respectively. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:78 / 83
页数:6
相关论文
共 25 条
  • [1] Automatic flow titrator based on a multicommutated unsegmented flow system for alkalinity monitoring in wastewaters
    Almeida, CMNV
    Lapa, RAS
    Lima, JLFC
    [J]. ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) : 291 - 298
  • [2] An automatic titrator based on a multicommutated unsegmented flow system -: Its application to acid-base titrations
    Almeida, CMNV
    Lapa, RAS
    Lima, JLFC
    Zagatto, EAG
    Araújo, MCU
    [J]. ANALYTICA CHIMICA ACTA, 2000, 407 (1-2) : 213 - 223
  • [3] Simultaneous multiple injection to perform titration and standard addition in monosegmented flow analysis
    Assali, M
    Raimundo, IM
    Facchin, I
    [J]. JOURNAL OF AUTOMATED METHODS & MANAGEMENT IN CHEMISTRY, 2001, 23 (03): : 83 - 89
  • [4] AUTOMATED CONTINUOUS-FLOW TITRATION
    BARTROLI, J
    ALERM, L
    [J]. ANALYTICA CHIMICA ACTA, 1992, 269 (01) : 29 - 34
  • [5] Monosegmented flow titrator
    de Aquino, EV
    Rohwedder, JJR
    Pasquini, C
    [J]. ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) : 67 - 74
  • [6] Determination of carbonate and hydrogencarbonate by titration using sequential injection analysis
    Fletcher, PJ
    van Staden, JF
    [J]. ANALYTICA CHIMICA ACTA, 2003, 485 (02) : 187 - 194
  • [7] LINEAR FLOW GRADIENTS FOR AUTOMATIC TITRATIONS
    GARCIA, IL
    VINAS, P
    CAMPILLO, N
    CORDOBA, MH
    [J]. ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) : 67 - 76
  • [8] A flow-batch titrator exploiting a one-dimensional optimisation algorithm for end point search
    Honorato, RS
    Araújo, MCU
    Lima, RAC
    Zagatto, EAG
    Lapa, RAS
    Lima, JLFC
    [J]. ANALYTICA CHIMICA ACTA, 1999, 396 (01) : 91 - 97
  • [9] IRVING HMN, 1969, PURE APPL CHEM, V18, P427
  • [10] Potentiometric flow titration of iron(II) and chromium(VI) based on flow rate ratio of a titrant to a sample
    Katsumata, H
    Teshima, N
    Kurihara, M
    Kawashima, T
    [J]. TALANTA, 1999, 48 (01) : 135 - 141