In Vitro Evaluation of Implant Surface Decontamination Methods Based on Removal and Regrowth of Microorganisms

被引:2
作者
Lee, Jung-Tae [1 ]
Jang, Il-Seok [2 ]
Moon, Jong-Hoon [3 ]
Yang, Seung-Min [4 ,5 ]
机构
[1] Seoul Natl Univ, Dent Hosp, Stop Specialty Ctr 1, Dept Periodont, Seoul, South Korea
[2] Osstem Implant, Biomat R&D Ctr, Seoul, South Korea
[3] Pusan Natl Univ, Sch Med, Biomed Engn, Yangsan, South Korea
[4] Sungkyunkwan Univ, Samsung Med Ctr, Dept Periodontol, Sch Med, Seoul, South Korea
[5] Sungkyunkwan Univ, Dept Med Device Management & Res, SAIHST, Seoul, South Korea
关键词
antimicrobial; biomaterials; implantology; local antimicrobial therapy; pathogenesis of periodontal diseases; PERI-IMPLANTITIS; DOUBLE-BLIND; CHLORHEXIDINE; BIOFILM;
D O I
10.11607/jomi.8878
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The efficiency of bacterial removal using mechanical and chemical methods and recurrence rates was evaluated based on infected implant surface removal modalities. Materials and Methods: The study comprises two main parts: in vitro bacterial removal (n = 49) and regrowth (n = 42) suppression tests on implant surfaces. Microorganisms were attached to each implant, and various methods were applied to clean the infected implants. The groups were allocated as follows: (1) no treatment, (2) cotton + saline, (3) brush, (4) scaler, (5) brush + scaler, (6) cotton + 3% H2O2, and (7) brush + 3% H2O2. All groups were further divided into two subgroups of mechanical treatment (3, 4, 5) vs mechanical + chemical treatment (2, 6, 7). After treatment for each group, immunofluorescence analysis and measurement using an ultravioletvisible light spectrophotometer were performed. Results: In the mechanical treatment group, the brush, scaler, and brush + scaler groups, all of which had strong polishing abilities, exhibited superior removal efficiency compared with the other groups (P < .001). In the regrowth experiment, 3% H2O2 effectively restrained biofilm formation. In particular, the brush + 3% H2O2 group exhibited significant differences from the mechanical treatment group (vs brush: P < .001, vs scaler: P = .023, vs brush + scaler: P = .005). Conclusion: Mechanical methods, including brushes and scalers, effectively removed bacteria. Biofilm formation was effectively restrained by H2O2. In particular, the brush + H2O2 group exhibited a superior ability to suppress bacterial regrowth compared with the other groups.
引用
收藏
页码:1088 / 1094
页数:7
相关论文
共 38 条
[1]   Surgical Treatment of Severe Peri-Implantitis Using a Round Titanium Brush for Implant Surface Decontamination: A Case Report With Clinical Reentry [J].
An, Yin-Zhe ;
Lee, Jae-Hong ;
Heo, Young-Ku ;
Lee, Jung-Seok ;
Jung, Ui-Won ;
Choi, Seong-Ho .
JOURNAL OF ORAL IMPLANTOLOGY, 2017, 43 (03) :219-227
[2]   Microbiological and immuno-pathological aspects of pen-implant diseases [J].
Belibasakis, Georgios N. .
ARCHIVES OF ORAL BIOLOGY, 2014, 59 (01) :66-72
[3]  
Block S. S., 2001, Disinfection, sterilization, and preservation
[4]   Efficacy of denture disinfection methods in controlling Candida albicans colonization in vitro [J].
Buergers, Ralf ;
Rosentritt, Martin ;
Schneider-Brachert, Wulf ;
Behr, Michael ;
Handel, Gerhard ;
Hahnel, Sebastian .
ACTA ODONTOLOGICA SCANDINAVICA, 2008, 66 (03) :174-180
[5]   The significance of infection related to orthopedic devices and issues of antibiotic resistance [J].
Campoccia, D ;
Montanaro, L ;
Arciola, CR .
BIOMATERIALS, 2006, 27 (11) :2331-2339
[6]   Mechanical and chemical implant decontamination in surgical peri-implantitis treatment: preclinical "invivo" study [J].
Carral, Cristina ;
Munoz, Fernando ;
Permuy, Maria ;
Linares, Antonio ;
Dard, Michel ;
Blanco, Juan .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2016, 43 (08) :694-701
[7]   Surgical Therapy of Peri-Implantitis with Local Minocycline: A 6-Month Randomized Controlled Clinical Trial [J].
Cha, J. K. ;
Lee, J. S. ;
Kim, C. S. .
JOURNAL OF DENTAL RESEARCH, 2019, 98 (03) :288-295
[8]   The effect of five mechanical instrumentation protocols on implant surface topography and roughness: A scanning electron microscope and confocal laser scanning microscope analysis [J].
Cha, Jae-Kook ;
Paeng, Kyeongwon ;
Jung, Ui-Won ;
Choi, Seong-Ho ;
Sanz, Mariano ;
Sanz-Martin, Ignacio .
CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (06) :578-587
[9]   The adjunctive effect of a titanium brush in implant surface decontamination at peri-implantitis surgical regenerative interventions: A randomized controlled clinical trial [J].
de Tapia, Beatriz ;
Valles, Cristina ;
Ribeiro-Amaral, Tiago ;
Mor, Carolina ;
Herrera, David ;
Sanz, Mariano ;
Nart, Jose .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2019, 46 (05) :586-596
[10]   Implant decontamination with 2% chlorhexidine during surgical peri-implantitis treatment: a randomized, double-blind, controlled trial [J].
de Waal, Y. C. M. ;
Raghoebar, G. M. ;
Meijer, H. J. A. ;
Winkel, E. G. ;
van Winkelhoff, A. J. .
CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (09) :1015-1023