Do Devices on PCBs Really See a Higher CDM-like ESD Risk?

被引:0
|
作者
Gaertner, Reinhold [1 ]
Stadler, Wolfgang [2 ]
Niemesheim, Josef [2 ]
Hilbricht, Oliver [2 ]
机构
[1] Infineon Technol, D-85579 Neubiberg, Germany
[2] Intel Mobile Commun, MCG WPRD ETS DSI ESQ, D-85579 Neubiberg, Germany
来源
2014 36TH ELECTRICAL OVERSTRESS/ELECTROSTATIC DISCHARGE SYMPOSIUM (EOS/ESD) | 2014年
关键词
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
There are several scenarios where integrated circuits (ICs) are mounted on Printed Circuit Boards (PCBs) which might be charged-up and experience CDM-like events. Those discharges are thought to be significantly more critical for the IC than a CDM event of single devices during qualification. The paper analyses the CDM-risk for ICs on boards in terms of discharge waveforms.
引用
收藏
页数:8
相关论文
共 11 条
  • [1] Inductor-Based ESD Protection under CDM-like ESD Stress Conditions for RF Applications
    Thijs, S.
    Okushima, M.
    Borremans, J.
    Jansen, P.
    Linten, D.
    Scholz, M.
    Wambacq, P.
    Groeseneken, G.
    PROCEEDINGS OF THE IEEE 2008 CUSTOM INTEGRATED CIRCUITS CONFERENCE, 2008, : 49 - 52
  • [2] A novel CDM-like discharge effect during Human Body Model (HBM) ESD stress
    Axelrad, V
    Huh, Y
    Chen, JW
    Bendix, P
    SISPAD 2002: INTERNATIONAL CONFERENCE ON SIMULATION OF SEMICONDUCTOR PROCESSES AND DEVICES, 2002, : 115 - 118
  • [3] A novel CDM-like discharge effect during human body model (HBM) ESD stress
    Axelrad, V
    Huh, Y
    Chen, JW
    Bendix, P
    IEICE TRANSACTIONS ON ELECTRONICS, 2003, E86C (03): : 398 - 403
  • [4] Investigation of ESD protection elements under high current stress in CDM-like time domain using backside laser interferometry
    Bychikhin, S
    Dubec, V
    Litzenberger, M
    Pogany, D
    Gornik, E
    Groos, G
    Esmark, K
    Stecher, M
    Stadler, W
    Gieser, H
    Wolf, H
    JOURNAL OF ELECTROSTATICS, 2003, 59 (3-4) : 241 - 255
  • [5] At-risk youth and locus of control do they really see a choice?
    Kelley, TM
    JUVENILE AND FAMILY COURT JOURNAL, 1996, 47 (04) : 39 - 53
  • [6] Do Sequential Compression Devices Really Reduce the Risk of Venous Thromboembolism in Plastic Surgery Patients?
    Swanson, Eric
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2015, 136 (04) : 577E - 578E
  • [7] Do nice men really have a higher risk of developing cancer? A prospective cohort trial and review of the literature
    Fine, PL
    Dogma, PS
    JOURNAL OF FAMILY PRACTICE, 1997, 44 (03): : 238 - 240
  • [8] Do drug-eluting stents really have a higher risk of stent thrombosis than bare-metal stents?
    Flores Rios, X.
    Barge Caballero, E.
    Campo Perez, R.
    Pinon Esteban, P.
    Aldama Lopez, G.
    Salgado Fernandez, J.
    Calvino Santos, R.
    Vazquez Rodriguez, J. M.
    Vazquez Gonzalez, N.
    Castro Beiras, A.
    EUROPEAN HEART JOURNAL, 2009, 30 : 240 - 240
  • [10] Intracardiac Devices Like Permanent Pacemakers or Cardioverter-Defibrillators Do Not Increase Stroke Risk in Patients With Patent Foramen Ovale
    Assar, Manijeh
    Sultan, Michael
    Gulati, Martha
    Al Rabadi, Salem
    Agarwal, Sumit
    Flores, Erica
    Habib, Adnan
    Bhardwaj, Supriya
    Sridhara, Srilekha
    Amabile, Orazio
    Tasset, Mark
    Gellert, George
    Villareal-Argente, Vidette
    Kelley, Claire
    Jasser, Zuhdi
    Kusne, Sharon
    Morris, Michael
    Byrne, Timothy
    Su, Wilbur
    Fang, Kenith
    Pershad, Ashish
    Verma, Divya Ratan
    CIRCULATION, 2017, 136