Quantitative diffusion imaging with steady-state free precession

被引:32
作者
Deoni, SCL
Peters, TM
Rutt, BK
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] Univ Western Ontario, Dept Diagnost Radiol & Nucl Med, London, ON, Canada
关键词
apparent diffusion coefficient; steady-state free precession; diffusion imaging; rapid volumetric imaging;
D O I
10.1002/mrm.10708
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The addition of a single, unbalanced diffusion gradient to the steady-state free precession (SSFP) imaging sequence sensitizes the resulting signal to free diffusion. Unfortunately, the confounding influence of both longitudinal (T-1) and transverse (T-2) relaxation on the diffusion-weighted SSFP (dwSSFP) signal has made it difficult to quantitatively determine the apparent diffusion coefficient (ADC). Here, a multistep method in which the T-1, T-2, and spin density (M-o) constants are first determined using a rapid mapping technique described previously is presented. Quantitative ADC can then be determined through a novel inversion of the appropriate signal model. The accuracy and precision of our proposed method (which we term DESPOD) was determined by comparing resulting ADC values from phantoms to those calculated from traditional diffusion-weighted echo planar imaging (dwEPI) images. Error within the DESPOD-derived ADC maps was found to be less than 3%, with good precision over a biologically relevant range of ADC values. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:428 / 433
页数:6
相关论文
共 50 条
[41]   Rapid anatomical imaging of the neonatal brain using T2-prepared 3D balanced steady-state free precession [J].
Park, Jinho ;
Jang, MinJung ;
Heier, Linda ;
Limperopoulos, Catherine ;
Zun, Zungho .
MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (04) :1456-+
[42]   Off-frequency tuning error artifact in steady-state free precession cine imaging due to adjacent air-filled bowel [J].
Sorrell, VL ;
Anderson, JL ;
Gatehouse, PD ;
Mohiaddin, RH .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2004, 6 (03) :709-716
[43]   Monitoring electrochemical reactions in situ using steady-state free precession 13C NMR spectroscopy [J].
Nunes, Luiza M. S. ;
Moraes, Tiago B. ;
Barbosa, Lucio L. ;
Mazo, Luiz H. ;
Colnago, Luiz A. .
ANALYTICA CHIMICA ACTA, 2014, 850 :1-5
[44]   Improved magnetization preparation for navigator steady-state free precession 3D coronary MR angiography [J].
Nguyen, TD ;
Spincemaille, P ;
Wang, Y .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (06) :1297-1300
[45]   Balanced steady state-free precession (b-SSFP) imaging for MRCP: techniques and applications [J].
Glockner, James F. ;
Lee, Christine U. .
ABDOMINAL IMAGING, 2014, 39 (06) :1309-1322
[46]   Balanced steady state-free precession (b-SSFP) imaging for MRCP: techniques and applications [J].
James F. Glockner ;
Christine U. Lee .
Abdominal Imaging, 2014, 39 :1309-1322
[47]   Contrast-enhanced Steady-state Free Precession in the Assessment of Hypertrophic Obstructive Cardiomyopathy after Alcohol Septal Ablation [J].
Amano, Yasuo ;
Yamada, Fumi ;
Kitamura, Mitsunobu ;
Tachi, Masaki ;
Mine, Kumiko ;
Kumita, Shinichiro ;
Takayama, Morimasa .
MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2016, 15 (01) :130-136
[48]   Black-blood steady-state free precession (SSFP) coronary wall MRI for cardiac allografts: A feasibility study [J].
Lin, Kai ;
Bi, Xiaoming ;
Liu, Ying ;
Taimen, Kirsi ;
Lu, Biao ;
Li, Debiao ;
Carr, James .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (05) :1210-1215
[49]   Navigator-gated three-dimensional MR angiography of the pulmonary arteries using steady-state free precession [J].
Hui, BK ;
Noga, ML ;
Gan, KD ;
Wilman, AH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (06) :831-835
[50]   Water-saturated three-dimensional balanced steady-state free precession for fast abdominal fat quantification [J].
Peng, Q ;
McColl, RW ;
Wang, JH ;
Chia, JM ;
Weatherall, PT .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (03) :263-271