Role of water contamination within the GC column of a GasBench II peripheral on the reproducibility of 18O/16O ratios in water samples

被引:21
作者
Rangarajan, Ravi [1 ]
Ghosh, Prosenjit [1 ,2 ]
机构
[1] Indian Inst Sci, Ctr Earth Sci, Bangalore 560012, Karnataka, India
[2] Indian Inst Sci, Divecha Ctr Climate Change, Bangalore 560012, Karnataka, India
关键词
continuous flow; GasBench; gas chromatography; GC column; IRMS; isotope measurements; methods and equipment; mass spectroscopy; oxygen-18; precision; water; HIGH-PRECISION; ISOTOPE; CARBON; O-18;
D O I
10.1080/10256016.2011.631007
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The GasBench II peripheral along with MAT 253 combination provides a more sensitive platform for the determination of water isotope ratios. Here, we examined the role of adsorbed moisture within the gas chromatography (GC) column of the GasBench II on measurement uncertainties. The uncertainty in O-18/O-16 ratio measurements is determined by several factors, including the presence of water in the GC. The contamination of GC with water originating from samples as water vapour over a longer timeframe is a critical factor in determining the reproducibility of O-18/O-16 ratios in water samples. The shift in isotope ratios observed in the experiment under dry and wet conditions correlates strongly with the retention time of analyte CO2, indicating the effect of accumulated moisture. Two possible methods to circumvent or minimise the effect of adsorbed water on isotope ratios are presented here. The proposed methodology includes either the regular baking of the GC column at a higher temperature (120 degrees C) after analysis of a batch of 32 sample entries or conducting the experiment at a low GC column temperature (22.5 degrees C). The effects of water contamination on long-term reproducibility of reference water, with and without baking protocol, have been described.
引用
收藏
页码:498 / 511
页数:14
相关论文
共 22 条
[1]  
[Anonymous], 2004, REVISION A, V111, P8342
[2]   Maintaining high precision of isotope ratio analysis over extended periods of time [J].
Brand, Willi A. .
ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2009, 45 (02) :135-149
[3]   Oxygen exchange reactions of organic compounds and water [J].
Cohn, M ;
Urey, HC .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1938, 60 :679-687
[4]   STANDARD FOR REPORTING CONCENTRATIONS OF DEUTERIUM AND OXYGEN-18 IN NATURAL WATERS [J].
CRAIG, H .
SCIENCE, 1961, 133 (346) :1833-&
[5]   Stable isotopes in the source waters of the Yamuna and its tributaries: seasonal and altitudinal variations and relation to major cations [J].
Dalai, TK ;
Bhattacharya, SK ;
Krishnaswami, S .
HYDROLOGICAL PROCESSES, 2002, 16 (17) :3345-3364
[6]   PORAPLOT-Q - A POROUS LAYER OPEN TUBULAR COLUMN COATED WITH STYRENE-DIVINYLBENZENE COPOLYMER [J].
DEZEEUW, J ;
DENIJS, RCM ;
BUYTEN, JC ;
PEENE, JA ;
MOHNKE, M .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (02) :162-167
[7]   13C and 18O fractionation effects on open splits and on the ion source in continuous flow isotope ratio mass spectrometry [J].
Elsig, Joachim ;
Leuenberger, Markus C. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (10) :1419-1430
[8]   Continuous flow 2H/1H and and18O/16O analysis of water samples with dual inlet precision [J].
Gehre, M ;
Geilmann, H ;
Richter, J ;
Werner, RA ;
Brand, WA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (22) :2650-2660
[9]   13C-18O bonds in carbonate minerals:: A new kind of paleothermometer [J].
Ghosh, P ;
Adkins, J ;
Affek, H ;
Balta, B ;
Guo, WF ;
Schauble, EA ;
Schrag, D ;
Eller, JM .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2006, 70 (06) :1439-1456
[10]   Stable isotope ratio mass spectrometry in global climate change research [J].
Ghosh, P ;
Brand, WA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 228 (01) :1-33